Text

Y

/,

u k / ]'

@ Commonwealth Edison Zion Generating Station Shiloh Blvd. & Lake Michigan Zion, Illinois 60099 Telephone 312/746-2084 July 12, 1979 Mr. James G.

Keppler, Regional Director Directorate of Regulatory Operations - Region III U.

S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Dear Mr. Keppler:

Enclosed please find a report of inservice inspection performed at Commonwealth Edison Co.,

Zion Unit 2 from March 19, 1979 through April 13, 1979.

This report is submitted to you in compliance with the requirements of Article IWA-6000 of Section XI of the ASME Boiler and Fressure Vessel Code 1974 Edition as required by Zion Technical Specification 4.3.4.C.

If there are any additional questions, picase contact Mr. R.

E.

Shannon at Zion Station.

Sincerely, 4A N. E. Wandke Superintendent Zion Station RES/lc cc:

J.

J. Marianyi (w/out Att.)

Y 790814oiss Q

W.

074