ML19242C582

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-04.Referenced Velan Valves Are Not Used in Category I Piping
ML19242C582
Person / Time
Site: Zimmer
Issue date: 05/29/1979
From: Borgmann E
CINCINNATI GAS & ELECTRIC CO.
To: Keppler S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 7908130047
Download: ML19242C582 (1)


Text

_.

/(

m, t

~

.ps

~

THE CINCINNATI GAS & ELECTRIC COMPANY st CIN CINN ATI.O HIO 4 52Oi May 29,1979 mh.^i.I.7.i."..^."".

U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 ATTN:

Mr. James G. Keppler, Director RE:

WM. H. ZIMMER NUCLEAR POWER STATION - UNIT 1 NRC IE BULLETIN 79-04 INCORRECT WEIGHTS VELAN SWING CHECK VALVES W.O. 57300, JOB E-5590, FILE # 956 DOCKET # 50-358 Gentlemen:

In response to the above NRC IE Bulletin, please be infonned that Velan valves of the referenced typed are not used in Category I piping at the WN1. H.

ZIMMER NUCLEAR POWER STATION - UNIT 1.

Very truly yours,

THE CINCINNATI GAS & ELECTRIC COMPANY pM ~

E.A. BORGMANN, SR. VICE PRESIDENT HCB/kjd cc:

U.S. Regulatory Comission Office of Inspection and Enforcement Division of Reactor Operations Inspection Washington, D.C.

20555 W.W. Schwiers S.G. Salay J.R. Schott W.D. Waymire J.D. Flynn H.C. Brinkmann W.E. Smith--San Jose o.J. Pruski--S&L General File n

,ia

' 0 1 1979 1

7008130047