ML19242B114
| ML19242B114 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek, Callaway, Sterling, 05000484 |
| Issue date: | 06/29/1979 |
| From: | Petrick N STANDARDIZED NUCLEAR UNIT POWER PLANT SYSTEM |
| To: | Grier B NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| SLNRC-79-10, NUDOCS 7908070526 | |
| Download: ML19242B114 (2) | |
Text
m,
,a a
SNUPPS Standardized Nuclear Unit Power Ptant System 5 Choke Chery Road Nicholas A. Petrick RockviPw, Maryland 20850 Executive Director (301)869 8010 June 29, 1979 SLNRC 79-10 r'ILE : 0278.10 SUBJ:
IE Bulletins 78-12,78-12A, and 78-128: Atypical Weld Material in Reactor Pressure Vessel Welds Mr. Boyce Grier Director, Region I Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Docket Nos.:
S7N 50-482, STN 50-483, STN 50-484, STN 50-485, and STN 50-486 Re f. :
Letter, A. E. Scherer (Combustion Engineering Inc.) to H. D.
Thornburg (I & E, USNRC), dat.ed June 8, 1979, LD-79-036, I & E Bulletin 78-12, " Atypical Weld Material in Reactor Pressure Vessel Welds"
Dear Mr. Grier:
This letter is submitted for the SNUPPS utilities in response ta the subject IE Bulletins.
The referenced letter forwarded a generic report which contained nost of the information requested by the subject Bulletins. This CE report is applicable to the reactor vessels for the SNUPPS plants.
I "aro No. 4 of Bulletin 73-12 requested information concerning the availability of archive weld materials.
CE does not maintain an inven-tory of archive materials for the welds addressed in the generic report.
Westinghouse, the SNUPPS NSSS supplier, will develop surveillance weld-ment data which will be documented following completion of the pre-irradi-ation testing program. Westinghouse will inventory archive surveillance weldment material which may used for verification purposes should excess material remain after...achining the surveillance weld material specimens from core region weld material.
Our review of the CE repor' forwarded by the referer.ced letter disclosed a few apparent errors.
CE nas agreed to correct the discrepancies and 519 3IO 7908070 Q (
SLNRC 79-10 June 29, 1979 Page Two will submit corrected pages to the NRC.
After changes to the CE report have been received and reviewed by the SNUPPS utilities and [1SSS supplier, the changes will be referenced in a supplemental response to the rubject Bulletins.
Very truly yours, q
Nicholas A. Petrick RLS/dck cc:
Mr. James G. Keppler, Director, Region III, USNRC Mr. Karl V. Seyfrit, Director, Region IV, USi1RC Mi. Victor Stello, Jr., Director, Office of Inspection and Enforcement, USNRC, Washington, D.C.
519 311