Form NRC 613 U.S. NUCLE AR REGUL ATCR Y CoMN110SICN ggCF\\'71 CERTIFICATE OF COMPLI ANCE For Radioactive Yaterials Packages 1.(g)A/ 6400/ge< ; fic,uEon No.

1 1.(e)6'otal No. Pages Pick aca i 1.t d l Pages No.

1.tal Cert ificat e Numt,er 1.lb) Rav3 on No.

da M

J 6400

/

2. P R E AP.1 tl L E 2.tal This certificate is issued tc, satisf y Sactions 173.393a.173.394,173.305. and 173.396 of the Cuartmant of Transmrtation Hazardous Materials Regulations (43 CFR 170-183 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Tr. isportation Cangerous Cargoes Regulations I 6 CF R 146-143). as amended.

2 lb)

The packa.;ing trst contents described in item 5 beiow. mee's the safety st andards set forth in Subpart C of Title 10. Code nf Federal Re;ulations. Part 71 " Packaging of Radioactive Yaterials for Tr nsport and Transportation of Radioactive Material Under Certain ConditionsJ 2.(c)

This certificate doe, not relieve the consignar fror" comcliance mth anv reaviremant of the regulations of the U.S. Ce. sr: ment of Transportation or ather acolicaole regulatory agenc >s including the governrrent of any country through or into whicn the package will be transported.

3. This certificate is issued on the basis of a sa.ety analys:s report of the package design or application-3.(a)

Prepared by (Name and adaress)

3. (b)

Title and identification of report or application-Westinghouse Electric Corporation Westinghouse Electric Corporation application P. O. Box 355 dated July 13, 1973, as supplemented.

Pittsburgh, Pennsylvania 15230 3.fcl Docket No.

7]_ gang 4 CONOiTIONS This certificate is cer%tional upon the fulfilling of the requirements of Subpart O of 10 CF R 71, as applicatie, and the corctioru specified in item 5 below.

5. Description of Packagin 3 arus Autnerized Contents. Yodel Numcer, F.ssile C' ass. Other Conditions. anri

References:

(a) Packaging (1) Model No.

Super Tiger (2) Descr'ption A protective overpik which provides containment, impact resistance and thermal resistance for its contents.

The containment vessel (cavity) is approximately 76" x 76 x 172" constructed of 3/16" thick and 10-gage mild steel.

Closure of the containment vessel is by a 1/4" thick aluminum plate with ;ilicone rubcer gasket whicn is tolted to the containment vessel. A pressure fitting with cap en tne closure plate provides a means for leak testing.

The containment vessel is centered and supportad in an outer 3/16" tnick-steel jacket by approx-imately 32" of polyuretnane foam insulation at the end and 10" on the sides. A removable section or cap consis"qq of approximately 34" of polyurethane foam insulation encased in steel with a silicone rubber gasket is bolted to the main cutcr steel jacket.

The cverall dimen-sions of tne packages are approximately 8' x 8' x ~20' Vent holes are provided on the sides and ends of the container.

Set into each corner of the cuter container are standard I.S.s steel castings.

The total weight including weight of the contents is 45,C00 pounds.

4 I

790 8 020M5 48+

U39

'Page 2 - Certificate No. 6400 - Revision No. 7 - Docket No. 71-6400 5.

(a) Packaging (continued)

(3) Drawings Packaging is constructed in accordance with Protective Packaging, Inc., Drawings Nos.

32106-1, Sheet I, Revision F; and 32106, Sheet 2.

(b) Contents (1 ) Type and form of material (i) Radioactive material including fissib. material as solids or liquids, in normal or special for. tackaged in secondary pack-aging which meets the requirements for Type A (49 CFR sl73.389(j))

packaging.

(ii) Radioactive material including fissile material as salids, in normal or special form packaged in secondary packag; _ which meets 00T Specification 17C or 17H 55-gallon steel drums.

Fissile material concentration shall be no more than 5 grams fissile materia l in any liter.

(iii) Radioactive material including fissile material as solids in normal or special form packaged in an inner containment vessel which conforms to DOT Specification 2R and with a maximum usable inside dimension of 5.25 inches. The inner containment vessel shall be centered and positioned within a 55-gallon macity 00T Specification 6J,17H, 6C or 17C steel drum by solid irdustrial cane fiberboard having a density of at least 0.249/cc oc of at least 4 steel rod radial spacers at 90 separation with bagged or tamped vermiculite having a density of at least 0.072 g/cc.

(iv)

Plutonium-bearing solid wastes packaged as follows:

Sof t waste (clastic sheetina, cloves, caser, crefilter media, polyetnviene totties, snoe covers, etc. )

Double-bagged in 12-mil thick PVC, with each bag heat-sealed (bag size nct exceeding 22" x 16" x IC") and packaged within a CnT Specification 17H 55-gal steel drum aith a sealed plastic bag liner and equipped with a standard drum closure.

Hard waste (ecuienent, metal cans, tools, etc.)

Sharp edged and pointed items shall be rounded off and blunted.

All items shall ce strip coated (by painting, dipping, spraying, etc.) to fix contaminai. ion prior to packaging. Glassware shall be c-"shed and sealed in metal containers.

Each item shall be doub.< bagged within 12-mil thick PVC, with each bag heat-sealed and packaged to reduce secondary impccts within CGT Specification 17H 55-gal steel drum with a sealed plastic bag liner equipped with a standard drum closure, i} b G

)J

  • m -=

i I

t Page 3 - Certificate No. 6400 - Revision No. 7 - Docket No. 71-6400 5.

(b) Contents (continued)

Solidified liauid waste Liquid waste shall be solidified in concrete in 30-gal drum which is sealed in a plastic bag and centered and supported in a DOT Specification 17H 55-gal steel drum by vermiculite, absorbent or plastic material.

The 55-gal drum shall be lined with a sealed plastic bag liner and equipped with a standard dr s closure.

Soft, hard, or solidified licuid waste shall not be comingled within the same DOT Specification 17H 55-gal steel drum.

Large ecuicment waste (alove boxes, furnaces, blowers, duct-wo.k. etc.)

Large equipment which will not fit into a 55-gal steel drum (see above contents) shall be encicsed in a tight fitting rectangular bnv constructed of 3/4" plywood.

The equipment contaminated surfaces shall be st-io coated (by painting, dipping, spraying, etc.) to fix contnination or otherwise sea'ed by pipe caps or gasketed blind flanges prior to packaging.

The space between the equiprent and the box shall be filled with foam or vermiculite.

Smaller strip coated (as outlined above) equipment items (which will not fit into a 55-gal drum) may be placed inside the larger piece of equipment (e.g., glove box) provided the space between the smaller and larger equipment is also filled with foam or vermiculite. All sharp or protruding objects from equipment shall be removed or blunted to eliminate the possibility of these objects damaging the packaging during normal or accident condi-tions of transit.

50xes shall not be comingled with 55-gal drums.

(2) Maximum quantity of material per package Plutonium in excess of twenty (20) curies per package except for Contents 5.(b)(1)(iv) above must be in the form of metal, metal alloy or reactor elements, and (i) For the contents described in 5.(b)(1)(i)':

Greater than Tyce A quantity of radioactive material in secondary packaging.

Fissile material contents per cackage not to exceed the generally licensed mass limits as specified in 10 CFR 571.11, (ii) For the contents described in 5.(b)(1)(ii):

Greater than Type A quantity of radioactive material in secondary packaging.

Forty-two, DOT Specificution 17C or 17H 55-gallon steel drums.

Each drum is limited to a maximum of 200 crams fissile material with no more than 5 gran,s fissile material in any liter and a maximum of 200 pounds of graphite.

/4 @ <

UJb

Pace 4 - Certificate No. 6400 - Revision No. 7 - Docket No. 71-6400 (ii)

For the contents described in 5.(b)(1)(iii):

Greater than Type A quantity of radioactive material in second-ary packaging.

Forty-two, 55-gallon capacity steel drums.

Each inner containment vessel is limited to a maximum of 500 grams fissile material with an H/V ratio not to exceed 20.

(iv)

For the contents described in 5.(b)(1)(i):

Greater than Type A quantity of radioactive material in secondary packaging.

Not more than 5 grams /cu f t fissile material.

(v)

For the contents described in 5.(b)(1)(iv);

Greater than Type A quantity of plutonium-bearinq waste materials in secondary packaging.

Each drum shipment shall consist oi forty-two (42) DOT Specification 17H 55-gal steel drums equipped with a standard drum closure.

Each drum or plywood box (as defined in 5.(b)(1)(iv)) is limited to 60 grams plutonium.

(c)

Fissile Class I, II and III (1) Fissile Class I F ' the Contents described in 5.(b)(1)(ii),

and 5.(b)(1)(iii) and limited in 5.(b)(2)(ii) and 5.(b)(2)(iii).

(2) Minimum transport For the contents described in 5.(b)(1)(i) index to be shown and limited in 5.(b)(2)(i):

on label for Class II As prescribed by 10 CFR 571.ll(b).

(3) Maxinum number of For the contents described in 5.(b)(1)(i) packages per ship.

and 5.(b)(1)(iv) and limitea in ment for Class III 5.(b)(2)(iv) and 5.(b)(2)(v):

Cne (1) 6.

The maximum weight of the contents including secondary packaging, dunnage, shoring and bracing must not exceed 30,CC0 pounds.

I 7.

The maximum decay heat generation per package must not cxceed:

(i) 30 watts and the heat sources are distributed throughout the cavity such that the temcerature at any coint within the cavity does not exceed 2CC'F, or (ii) 235 watts provided combustible solids or liquids are not present and the heat sources are distributed throughcut the cavity such that the internal surface temperature of the cavity walls will nowhere exceed 350 F,

{

U J's

/] d u

Page " - Certifit

,u, iOO - Revision No. 7 - Docket No. 71-6400 8.

The c' its described ir 5.(b)(1)(i), 5.(b)(1)(ii) and 5.(b)(1)(iii) and in 5.(b)(2)(i). 5.(b)(2)(ii) and 5.(b)(2)(iii) may be intermixed.

limie :

Further, these contents may be intermixed with specification containers and packages authorized pursuant to 10 CFR 5571.12(a) and 71.12(b) provided the total transport index within the package based on fissile considerations dues not exceed 50, the package is shippen as Fissile Class III with one (1) package per shipment and all other terms ant conditions of this certificate are met.

9.

For less than full loads, sufficient dunnage, shoring and/or bracing shall be utilized to minimize secondary impact of the secondary packaging witnin the cavity under normal and accident conditions.

10.

Protrusions from secondary packaging such as lif ting eyes, etc., shall be positioned such that they will not contact the cavity walls, or shoring shall be provided to prevent pur;cture of the cavity walls by the protrusions under the normal and accident conditions.

11.

Radiation shielding as required shall be an integral part of the secondary packaging.

12. Contents shall be positioned in the cavity such that the center of gravity of the loaded package is substantially the same as the center of gravity of an empty package.
13. A leak test shall be conducted of each package prior to delivery to a carrier for transport to ensure that it is properly sealed. The leak test may be omitted if the contents meet the requirements of special form as defined in 10 CFR i71.4(o).

14.

Shipment of liquids where freezing may be encountered must receive approval with regard to arrangements made to prevent freezing of the contents.

15.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

16.

Expiration date:

February 23, 1980.

REFERENCES Westinghouse Electric Corporation application dated July 13, 1,073.

Supplements dated: April 3 and June 7, 1979.

Me'hanics Resa rch, Inc., Reoort C2378, " Engineering Evaluation of the Super Tiger Overpack Designed for the Shipment of Large Quantities of Hazardous Materials."

a o' i

Page 6 - Certificate No. 6400 - Revision flo. 7 - Docket No. 71-6400

References:

(Cont'd) fluclear Materials and Equipment Corporation's application dated September 17, 1971.

Supplement dated: January 6,1972.

Nuclear P.el Services Inc. application dated July 6,1979.

FOR THE U.S. NUCLEAR REGULATORY CCMMISSION W

f

.44 Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

)'

t

._.