Preliminary Reccr on TCRNADO DAMAGE SURVEY OF THE WICHITA FALLS AND VER'iCN TEXAS TORNADOES Of April 10, 1979 by James R Mcdonald Joseph E. Minor April 20, 1979
;STITUTE FOR DISASTER R SEARC'
'EXAS TECH UNIVERSITY Box 4CS9 Lubbock, Texas 79A09 4
7907'60 17 2
/ '0) n t
v I;
w:
Cn the a'ternoon of April 10, 1979 Northeast Texas a".v Southe,.
J..lancma were struck by an outoreak of several tornadoes.
The two most severe ones hit Vernon and W chita' Falls, Texas.
We first ob-served damage from the Vernon tornado 4 miles southwest of the Lockett ccm unity.
It traveled through the Southeast edge of Vernon and cros-sed US 2d7 2 miles east of the downtown area.
The storm is believed to have crossed the Red River and continued toward Holister and Lawton, Cklahoma.
The Wichita Falls tornado cut a wide swath of dam. age through the southern half of tne city.
Damage u_,
first ob-served when a major power transmission line to the city was cut two miles southwest of the football stadium.
The tornado proceeded througn the southern half of the city in an east-northeasterly direction devastating a heavily populated reaicential area.
The patn thrcugh the city was approximately on? mile wide and 11 miles long.
The last visible evidence of the path that we observed was five miles south of Petrolia, Texas.
The Institute for Disaster Researci sent two, two-man teams to investigate the damage at Wichita Falls and Vernon.
The first ter. departed cubbock at 5:00 a.m. on April 11.
They documented the damage in Vernon and then proceeded to Wichita Falls, arriving about 1:00 p.m.
This team, made up of Dr. Joseph E. Minor and Dr.
Richard Petersen, remained in Wichita Falls through Thursday April 12.
T"e second team consisting of Dr. Jim Mcdonald and Dr. Paul Gi'lett 3rrived in Wichita Falls late Wednesday night.
Thursday surveys of both Wichita Falls and morning was spent making aeri d; 4 c. m s
- r<',-
.. si t
'J e - a n r a Cessna 172.
This second team reamired in W:ct.ita Falls unitl S u r. 2 2, nigrt The too teans took more that 1000 photographs of the damage.
Oreliminary assessnent of the dar. age by the Institute personnel ra*es tre a'icnita Falls tornado as an Ff,, based on " appearance" of da age" Co-carison of the extent of damage with other tornado even.5, lo.ds them to conclude tnat the maximum windspeeds were prctably in the range of 175-225 moh.
Evidence cited for these wincsceed estimates include:
(1)
Residences and Apartment Complexes Only the strongest walls on well-built residences re-mained standing.
Upper floors of apartment builcings were blown away.
(2)
Engineered Structures The football stadium, McNiel Jr. High School, Een Milam Elementary Scnool, Sikes Senter shopping mall, and the Levi Strauss plant all suffered extensive danage.
(3)
Light Connercial Structures Damage to Safeway store, Csborn's Department store, fast food resturants and small individual businesses was devastating.
(c)
Pre-Engineered Metal and Tilt-Up Construction Complete destruction of Sears warehouse, grain storage buildings, snall manufacturing plant and cacer goods warenouse was observed.
(5)
"obile Hcmes Candlenood *>.obile Hore park was totally destroyed.
'E' Wind-Generated Missiles Automotiles were tossed and tumoled as much as 200 ya-as.
Steel roof trusses were trans;orted one-nalf mile Dy the winds.
10 1
_i
?
The terr.c, tornado is also rated F4 by the Inst':tute team based on apperance of damage" Maximum wir.dspeeds are believed to be in
- ne 153-200 moh rar.ge.
Evidence far these preliminary windspeed estimates include:
(1)
Residential Camage Only the strongest walls of residences remained standing,
(2)
Engineered Structures Facilities of the Texas Highway Departrent were extensively danaged.
(3)
Light Ccnmercial Buildings A motel and resturant on US 287 were leveled.
(4)
Jenerated !!issiles Several deaths in the Vernon tornado occurred because persons were caucht in autcmobiles that were tossed and tumbled by the winds.
Large tractors and other farm machineary were rolled and tumbled up to 100 yards.
The Institute ' tentatively plans
^.o conduct a number of studies relating to these two tornado events.
These studies include:
(1)
Near Ground Windfields Plot the exact extent of damage, provide input for final F-scale rating of the tornadoes study debris patterns that can be related to windfield characteristics, esticate windspeeds f rom structural calculations, determine pcrcent damage by F-scale or windspeed witnir. the Wichita Falls path.
(2)
Occupant Protection Identify areas of safety for occupant protection in schools, cnurches, shccoing centers and medical facilities, propose metnods for occupant protection as the two cities recuild.
(31 --Vobile Hores
- centify those nobile bene units that perfcrmed the best in tre storm, study anchor characteristics, identify !"ose
~
,q 3
units that had HUD identification numbers and compare their performance with older models (EUD models have more stringent structural design criteria),
(4)
Missiles Identify the various types of wird-generated missilds ar.d determine their poir.t of origin, correlate with trajectories predicted by ccmp;ter models.
Research and reporting efforts by the Institute will be co-ordinated with Ted Fujita, University of Chicago, Bob Abbey, NRC, Charles Yancey, NB3, Roger Glass, Center for Disease Control, and personnel of the Texas Manufactured Hcme Federation, Copies of phctographs and other documentation are available from the Institute for Disaster Pesearch.
Support for this damage documentation effort is provided in rart by the Nuclear Requiatory Commission (Contract NRC-04-76-345) and by the Institute for Disaster Research.
g S.. J t
4