y p
Washington Public Power Supply System A JOINT OPERATING AGENCY P. O Don 96E 3000 G a o, W A S HIN G T ON War HrcHL AND. WasHtNGrc 993'52 PHONE (509) 375-5000 Docket fiumbers 50-460 and 50-513 May 29, 1979 G01-79-309
'Li '
Mr. R. H. Engelken, Director U.S.,,oclear Regulatory Conmission
/@ kk,p Region V dgy OJ j
,Q Suite 202, Walnut Creek Plaza 1990 fl. California Boulevard g3 Walnut Creek, CA 94596 s' e
Subject:
WPPSS fiUCLEAR PROJECTS fl05. 1 & 4 IE BULLETIf!S f;0S. 78-12,78-12A AtiD 78-12B
References:
1)
Letters, R. H. Engelken to fl. O. Strand, Same Subject, September 29, 1978, flovember 24, 1978 and March 19, 1979.
2)
Letter, J. H. Taylor (B&W) to W. G. Reinmuth (f!RC),
" Response to IE Bulletins 78-12 and 78-12A', fiarch 13, 1979.
Dear Mr. Engelken:
In response to the subject bulletins transmitted by the Reference 1 letters, WPPSS offers the following.
With Reference 2, the Babcock & Wilcox Company (B&W) submitted to the fiRC a report entitled " Records Investigation Report Related of Off-Chemistry Welds in Material Surveillance Specimens and Response to IE Bulletins 78-12 and 78-12A Supplement".
It is our understanding that reference to reactor vendor reports is acceptable in fulfilling our obligation as described in IE Bulletin 78-12 and 78-12A Supplement.
WPPSS has reviewed the information included in the report and concludes that there is no reason to suspect that atypical weld wire was used in the fabrication of the WilP-1/4 reactor vessels.
B&W has also assured WPPSS that the weld material information provided in the report covers the WilP-1 and Wf1P-4 reactor vessels.
Should you have any questions with regard td our response, please contact me.
Very truly yours, c5 A^V D. L. REflBERGER Assistant Director-Technology DLR:ADCK:ct Attachment Mr. C. R. Bryant, BPA 2
fiRC, Office of Inspection and Enforcement (Washington D.C.y 0 9 042 cc:
\\
290209027 6
.. w a,