Forwards LER 79-014/01T-0
Date released: 09/12/2019 Download: ML19241A667


LER 79-014/01T-0 on 790618:special Radiographic Insp of Three Steam Generator nozzle-to-feedwater Piping Welds Showed Cracking in Three Inlet Elbows.Caused by Fatigue Failure Assisted by Corrosion.Elbows Replaced
ML19241A668
Person / Time
Site: Beaver Valley
Issue date: 07/02/1979
From: Werling J
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19241A668 (2)
Forwards LER 79-014/01T-0
ML19241A666
Person / Time
Site: Beaver Valley
Issue date: 07/02/1979
From: Werling J
DUQUESNE LIGHT CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19241A666 (2)