ML19240B957

From kanterella
Jump to navigation Jump to search
Forwards Nonproprietary & Proprietary Versions of 1981 Calvert Cliffs Unit 2 Refueling Outage:End of Cycle 3 Eddy Current Insp Results on Control Element Assemblies. Proprietary Version Withheld (Ref 10CFR2.790)
ML19240B957
Person / Time
Site: Calvert Cliffs  
Issue date: 04/10/1981
From: Lundvall A
BALTIMORE GAS & ELECTRIC CO.
To: Clark R
Office of Nuclear Reactor Regulation
Shared Package
ML19240B958 List:
References
NUDOCS 8104170379
Download: ML19240B957 (1)


Text

W B ALT I M O R E GAS

.4*'O ELECTRIC.

/

CH ARLES CENTER. P.O BOX 475 Ba.LTLMORE, MARYLAND 21203 Aamsa c. Lu~ovm. J" A ri! 10 1981 VECL 67tCBlDONT P

DUPPL Y Office of Nuclear Reactor Regulation U.. S. Nuclear Regulatory Commission Washington, D. C. 20555 ATTENTION: M r. P.. A. Clark.. ' Ji f Ocecating Reece urauch (/3 Divition of Liceruing SG3LCT: Calvert Cliffs Nuclear Power Piara

._ ain No. I and 2, rockc Nm. 50-W and 50-31G CEL Guide Tube In. ectier Prrgram REFER ENCE (A): NRC Letter fram R. A, Clark to A. E. Lundvall, Jr.

Amendment No. 31 to Clavert Cliffs Unit No. 2 Operating License No. DPR G Gentlemen:

Reference (A) requesteo

  • hat we provide a final report concerning the subject p:rgram.

Enclosed are i'mprietary and non-proprietary copies of CEN-154(BL praviding the requested information. Alte enclosed is a signed affidavit exec.:ted by Con &ustion Enginee:Ing, Inc. in support of 15eir request that the material contair.ed in CEN-154(B)-P be withheld from pubhc di. closure in acccreance with the p:ovi: Lons of 10 CFR fiart 2.790.

The two references for CEN-154(B)-P were submitted to the Com.nissica earlier.

Reference 1, CEN-II8(B)-P, s.as submitted with the R. C. L. Olson to R. W. Reid letter of Nevernber 12,1979. Reference 2, CEN-116(B)-P, was submitted with the R. C. L. Olson to R. W. Reid letter o' October 10,1979.

Very truly yours, BALTIMORE GAS AND ELECTRIC COMPANY'

/

/

,/

/

f 4 ?_ r i f gg o. /i %

/

A. E. Lancvall, Jr.

/

Vice President - Suoply

/

AEL/ JAM /djw Encio.sures:

(1) CEN-154(B)-P (Copies 1-40)

(2) CEN-154(B)-NP (20 copies)

(3) Signed Affidavit (40 copies) cc:

3. A. Biddison, Esquire (w/o enci)

G. F. Trowbridge, Esquire (w/o encl)

Mr. E. L. Coriner, Jr., - NRC (w/o encl) p Mr. P. W. Kruse - CE (w/o enc 1) 810 41 '7 0 $73 i