August 28, 2019 PARTIALLY CLOSED - MEETING NOTICE Organization:
Gesellschaft für Nuklear-Service mbH (GNS)
Date:
September 11, 2019 8:00 a.m. - 4:00 p.m. (Eastern Daylight Time)
Location:
U.S. Nuclear Regulatory Commission (NRC)
One White Flint North, Room O-4B6 11555 Rockville Pike Rockville, MD 20852
Purpose:
Pre-application for Model No. CASTOR geo69 transportation package
Participants:
NRC/NMSS/DSFM GNS John McKirgan, et al.
Jens Schrder, et al.
Meeting Category: This is a Category 1 Meeting. The public is invited to observe this meeting and will have one or more opportunities to communicate with the NRC after the business portion, but before the meeting is adjourned. The NRCs Policy Statement, Enhancing Public Participation on NRC Meetings, effective May 28, 2002, applies to this meeting. The policy statement may be found on the NRC website, www.nrc.gov, and contains information regarding visitors and security.
The NRC provides reasonable accommodation to individuals with disabilities where appropriate. If you need a reasonable accommodation to participate in this meeting, or need the meeting notice or the transcript or other information from the meeting in another format (e.g., Braille, large print), please notify the NRC's meeting contact. Determinations on requests for reasonable accommodation will be made on a case-by-case basis.
Contacts:
Bernard White (301) 415-6577, Bernard.White@nrc.gov Attendance on the phone at for this meeting by other than those listed above should be made known by September 9, 2019, by phone or e-mail to the above contact.
Docket Nos.
Enclosure:
Agenda
ML19240B366 OFC DSFM DSFM NAME BWhite SFigueroa DATE 8/28/19 8/28/19
Agenda for the Pre-Application Meeting Between NRC/Gesellschaft für Nuklear-Service mbH Meeting September 11, 2019, 8:00 a.m. - 4:00 p.m.
Discussion PUBLIC MEETING
- 1. General Package Design (15 min)
- 2. Current Status of the Project (15 min)
CLOSED MEETING
- 1. Specific Information on Package Design (30 min)
- a. Design Features of the Package and CLU
- b. Radioactive Content
- c. Engineering Drawings / Parts List
- 2. Structural Evaluation (3h)
- a. Design Evaluation of each main component
- i. Material Characterization and Validation of Impact Limiter ii. Evaluation of cask body (incl. Fracture Toughness) iii. Evaluation of basket iv. Evaluation of canister (incl. mock-up test for leakage rate determination)
- b. Validation of Methods for Calculations
- 3. Thermal Evaluation (15 min)
- a. Calculation Models
- b. Preliminary Results and Conclusions
- 4. Containment (15 min)
- a. Calculation Approach
- 5. Shielding Evaluation (30 min)
- a. Calculation Models
- i. Detailed Content Information and Loading Pattern ii. Methods for Source Term Determination
- b. Preliminary Results and Conclusions
- 6. Criticality Evaluation (30 min)
- a. Criticality Safety Concept
- b. Calculation Code and Model
- i. Deformation of FA ii. Fuel release after fuel rod failure iii. Uncertainty of ku
- 7. Quality Assurance (30 min)
- 8. Concluding Discussion (30 min)