ML19238A342
| ML19238A342 | |
| Person / Time | |
|---|---|
| Site: | Clinton |
| Issue date: | 08/23/2019 |
| From: | Joseph Demarshall AmerGen Energy Co |
| To: | NRC/RGN-III/DRS/OLB |
| Demarshall J | |
| Shared Package | |
| ML17164A361 | List: |
| References | |
| Download: ML19238A342 (2) | |
Text
ES-401 Record of Rejected K/As - ILT 17-1 NRC Written Exam Form ES-401-4 Tier /
Group Randomly Selected K/A Reason for Rejection RO T2 G2 (Q38) 204000 A1.09 went to 286000 A1.01 Facility was unable to write a question that has 3 plausible distracters. Per facility, operating RWCU system controls will have two impacts on RWCU conductivity, either causing conductivity to raise or lower. Without asking additional information outside the K/A, the question cannot be written with 3 plausible distracters.
This is also true for the remaining A1 statements. Facility requested reselection either a different system that is not currently being sampled (preferred to maintain outline balance), or a different category within 204000.
2/16/18 - BASED ON DISCUSSION WITH CHIEF EXAMINER:
Randomly re-selected 286000 A1.01 to maintain outline balance.
RO T1G2 (Q59) 295033 2.2.12 went to 295029 2.4.6 Facility determined that 2.2.12 (Knowledge of surveillance procedures) is incompatible with 295033. In addition, the secondary containment EPEs are oversampled between the audit and NRC exams.
Audit RO Q65 - 295035 A2.01 Audit RO Q59 - 295036 K1.02 NRC SRO Q85 - 295036 2.1.32 2/16/18 - BASED ON DISCUSSION WITH CHIEF EXAMINER:
Randomly re-selected 295029 from the available T1G2 APE/EPEs, and 2.4.6 from the available K/As appropriate for Tiers 1 and 2 listed in ES-401 D.1.b.
SRO T2G2 (Q17/92) 215001 2.1.7 went to 233000 2.1.7 Facility was unable to write an operationally valid question to 215001 since SROs at facility dont make operational judgments about the plant based on TIP traces.
3/15/18 - BASED ON DISCUSSION WITH CHIEF EXAMINER:
Randomly re-selected 233000 from the list of available T2G2 systems not sampled on the RO exam, and retained 2.1.7 to maintain outline balance.
SRO T2G2 (Q18/93) 201001 A2.13 went to 201001 A2.04 Facility was unable to develop a psychometrically sound question for K/A A2.13 at the SRO license level. Loss of CRD cooling water flow does not require entry into ITS or any Off-Normal procedure.
4/11/18 - BASED ON DISCUSSION WITH CHIEF EXAMINER:
Randomly re-selected 201001 A2.04 to maintain outline balance.
SRO T2G1 (Q14/89) 262001 A2.11 went to 262002 A2.01 Facility was unable to develop an acceptable SRO level question to meet this K/A without overlapping concepts tested in ILT 17-1 NRC Scenario 1 Event 6 (Trip of the ERAT SVC), including evaluation of ITS 3.8.1.
4/12/18 - BASED ON DISCUSSION WITH CHIEF EXAMINER:
Randomly re-selected 262002 A2.01 from the available T2G1 systems that have only been sampled once on the RO and SRO exams (215004, 215005, 218000, 239002, 259002, 261000, 262002, 263000, 264000, 300000, and 400000).
ES-401 Record of Rejected K/As - ILT 17-1 NRC Written Exam Form ES-401-4 Tier /
Group Randomly Selected K/A Reason for Rejection RO T2G1 (Q23) 223002 K1.13 went to 223002 K1.10 Facility was unable to write an operationally valid question to 223002 K1.13 on the basis of low operational validity. TIPs are operated by the Reactor Engineers and not licensed operators. In addition, the only interrelationship that TIPs has with PCIS is that purge air to the TIPs is supplied from the Plant Service Air (SA) system, and while TIP operation with SA is desirable, it is not required.
4/24/18 - BASED ON DISCUSSION WITH CHIEF EXAMINER:
Randomly re-selected 223002 K1.10 from the remaining statements in 223002 K1 to maintain outline balance.
RO T1G1 (Q46) 295024 K2.16 went to 295024 K2.19 Post 75 Day Submittal Change to Outline 295024 K2.16 rejected due to inability to write a question to the K/A that was not LOD=1.
7/18/18 - BASED ON DISCUSSION WITH CHIEF EXAMINER:
Randomly re-selected 295024 K2.19 to maintain outline balance.
SRO T1G1 (Q1/76) 295019 A2.02 went to 295030 A2.01 Post 75 Day Submittal Change to Outline 295019 A2.02 rejected due to inability to write a psychometrically sound question at the SRO license level.
7/18/18 - BASED ON DISCUSSION WITH CHIEF EXAMINER:
Randomly re-selected 295030 A2.01.
SRO T2G1 (A15/90) 217000 2.2.46 went to 217000 2.2.40 Post 75 Day Submittal Change to Outline 217000 2.2.46 rejected due to inability to write a psychometrically sound question at the SRO license level.
7/18/18 - BASED ON DISCUSSION WITH CHIEF EXAMINER:
Randomly re-selected 217000 2.2.40 from the list of available Generic K/As listed in ES-401 D.1.b that are not sampled on the ILT 17-1 NRC exam.