ML19227A289

From kanterella
Jump to navigation Jump to search
6-6-19 Email from C. Thompson (NNSA) to N. Garcia Santos (NRC) RAI Thoughts, Model No. 435-B, 71-9355, Ml_________________; 2) 435-B, Rev. 3, Rais, ML19126A141, and 3) RAI Thoughts from NNSA, ML19161A155
ML19227A289
Person / Time
Site: 07109355
Issue date: 06/06/2019
From: Catherine Thompson
US Dept of Energy, National Nuclear Security Admin
To: Garcia-Santos N
Office of Nuclear Material Safety and Safeguards
NGarcia-Santos NMSS/DSFM/SFLB 415.6999
References
Download: ML19227A289 (2)


Text

From:

Thompson, Chad E To:

Garcia Santos, Norma Cc:

Thompson, Chad E; Taplin, Temeka; Wald-Hopkins, Mark David; Chavez, David Michael; Gordon, William; Durham, Stacey M.; Thorp, Donald Thomas; Love, Diana L

Subject:

[External_Sender] FW: NRC RAI 20190516 l 435-B Rev. 5 Date:

Thursday, June 06, 2019 5:08:53 PM Attachments:

NRC RAI 20190516.pdf 435-B SAR Rev. 5 RAIs Draft Thoughts.docx Good afternoon Norma,

Thank you very much for your support, insight, and updates. As a follow-up to our earlier phone call, Im sending over Oranos initial thoughts document which captures the areas where they are seeking clarification.

I would like to respectfully request your take on the attached initial thoughts document to see if you think a conference call would be appropriate to address their questions or if this rises to the technical level requiring a public meeting request.

Thanks again to giving this a look and I look forward to your response.

Semper Fi, Chad E. Thompson National Nuclear Security Administration Office of Packaging and Transportation, NA-531 Chad.Thompson@nnsa.doe.gov (505) 845-4114 "The price of freedom is eternal vigilance."

Thomas Jefferson

From: Chavez, David Michael [1]

Sent: Thursday, June 06, 2019 1:25 PM To: Thompson, Chad E <chad.thompson@nnsa.doe.gov>

Subject:

[EXTERNAL] FW: NRC RAI 20190516 l 435-B Rev. 5 FYI

From: CRIDDLE Tom (ORANO) <tom.criddle@orano.group>

Sent: Friday, May 24, 2019 11:37 AM To: Wald-Hopkins, Mark David <mwaldhop@lanl.gov>; Chavez, David Michael <d_chavez@lanl.gov>;

Coel-Roback, Becky <becky_cr@lanl.gov>

Cc: NOSS Philip (ORANO) <phil.noss@orano.group>

Subject:

RE: NRC RAI 20190516 l 435-B Rev. 5 Hi Mark,

Please see the attached draft thoughts on the NRC RAIs to 435-B SAR Rev. 5.

Once NA-531 sends the questions formally, we should probably have a discussion with them, at least about the first RAI. Then we need a discussion with NWP/Sellmer, and finally a discussion with NRC on a couple of points. Then we can proceed and revise the SAR. We are planning for this to be Revision 5.1. We will save Revision 6 for the next version with substantial new material.

Please let us know if you have suggestions or questions on the RAIs, and when the discussions can be planned.

Thank you,

Tom Criddle Project Manager Orano Federal Services LLC 505 S. 336th Street, Suite 400 Federal Way, WA 98003 253-552-1337 office tom.criddle@orano.group

From: Wald-Hopkins, Mark David [2]

Sent: Wednesday, May 22, 2019 9:54 AM To: CRIDDLE Tom (ORN-RE); NOSS Philip (ORN-RE)

Cc: Chavez, David Michael; Coel-Roback, Becky

Subject:

FW: NRC RAI 20190516.pdf Security Notice: Please be aware that this email was sent by an external sender.

Tom and Phil,

See attached as discussed earlier.

Mark