'Rt'm m
~~""vrtxwpl'NDIANA II MICHIGAN POWER COMPANY P. 0. BOX 18 BOWLING GREEN STATION NEW YORK, N. Y. 10004 May 3Q, 1978 AEP:NRC:
00007 Donald 'C. Cook Nuclear Plant Units 1 and 2
Docket Nos.
50-315 and 50-316 Operating License Nos.
58 and 74 Mr. Edson G.. Case, Acting Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D. C.
20555 4
Dear Mr. Case:
This letter is transmitted in fulfillment of license condition 4.B of Amendment No.
4 to Operating License No.
DPR-74 which requires that the Indiana 6 Michigan Power Company provide for NRC staff review the results of qualification testing per-formed in conformance with IEEE 323-1971 requirements for all electrical terminations in all safety-related circuits inside containment for postulated steamline break and/or 1'oss of coolant accident conditions.
Attachment No.
1 to this letter further amplifies information presented in our April 21, 1978 letter to you and was discussed with members of your staff on April 28, 1978.
This attachment includes the following reports:
(2)
Instrumentation Cable/Penetration Wire Interface in Cook Nuclear Plant Unit 2 Safety-Related Circuits Inside the Containment.
Control Terminal Blocks Inside Containment.
(3)
Continental Wire Company Instrumentation Cable.
These reports include a specific description of Samuel Moore Cable.
Information concerning justi~"'cation of a 60 x 106 rad integrated dose in the pipe tunnel was also requested by your staff.
A final report on this item is currently under preparation and will be transmitted to you shortly.
Edson G.
Case May 30, 1978 Attachment No.
2 to this letter is a summary of all environmental qualification for safety-related equipment and terminations that has been 'done to date.
Attachment No.
3 to this letter includes all test reports concerning environmental qualification of equipment.
Attachment No.
4 to this letter is a photograph of floodup tubing at. an electrical instrumentation penetration.
Very truly yours, Jo z gh st V'
President Sworn and subscribed to before me this 3o~day of May, 1978 in New York County, New York Notary Public
'i&ILEIN D~g NOTARY VUBLlC, State of New York i%0. 4l I6ff679Z Quefified in C>ueenr County Certifieete filed in New York County Conunta5loll erulreS re%en dtf> ly7'y CC R.
C..
C allen G. Charnoff
-R. Walsh R. J. Vollen D. V. Shaller-Bridgman R.
W. Jurgensen P.
W. Steketee
'ds'on G. Case i ay 36, 1.978 bc:
S. J. Nilioti/J. G. Feinstein K. J. Vehstedt/Environmental File R. F. Hering/S.
H. Steinhart, G. P. Field H. N. Scherer, Jr.
R. F. Kroeger DC-N-6015.1 T. Baker E.
Reeves NRC N. Nlynczak NRC J.
C. Jeffrey OC-N-6079