ML19225A800

From kanterella
Jump to navigation Jump to search
Forwards Rise-to-Power Test Program RT-508,Revision 3. Purpose of Test Was to Define Instrumentation & Instrumentation Utilization Methods for Fluctuation Testing Under Test RT 500E
ML19225A800
Person / Time
Site: Fort Saint Vrain 
Issue date: 07/12/1979
From: Warembourg D
PUBLIC SERVICE CO. OF COLORADO
To: Kuzmycz B
Office of Nuclear Reactor Regulation
Shared Package
ML19225A801 List:
References
P-79153, NUDOCS 7907200264
Download: ML19225A800 (1)


Text

.I I

! public service company =51e c:::n rz:

P. O. Box 361, Platteville, C0 306 July 12, 1979 Fort St. Vrain Unit No. 1 P-79153 Mr. George Kuzmycz, Project Manager U. S. Nuclear Regulatory Commission Division Project Management Special Projects

'Jashington, D.C.

20555 Subj ec t :

Fort St. Vrain, Rise to Power Test Program, RT-503

Dear Mr. Kuzmyc :

Per your request, I am forwarding for vour information one (1) copy of RT-503, Revision 3.

The purpose of this test is to define the instrumentation and the metheds of utilizing this instrumentation for fluctuation testing under RT 300E.

Very truly yours, U$ ThuJM Don Warembourg

</

Manager, Nuclear Production DW:dkm cc: w/ attachment Duane Frye Instrument Control Div.

P. O. Box X Gak Ridge, TN 37330 g"/

0

\\

366 229 Y %

7 907eo o A6c/