ML19224D009

From kanterella
Jump to navigation Jump to search
Forwards LER 79-066/03L-0
Date released: 08/26/2019 Download: ML19224D009


LER 79-066/03L-0 on 790609:fire Alarm Point Alarmed, Although Investigation Revealed No Fire.Cause Suspected to Be Dust or Dirt on Detector.Detector Removed,Tested & Reinstalled
ML19224D012
Person / Time
Site: Davis Besse 
Issue date: 07/05/1979
From: Chesko R
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19224D012 (2)
Forwards LER 79-066/03L-0
ML19224D008
Person / Time
Site: Davis Besse 
Issue date: 07/05/1979
From: Murray T
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19224D008 (1)