ML19224B702
| ML19224B702 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 05/16/1979 |
| From: | Snaider R Office of Nuclear Reactor Regulation |
| To: | Eisenhut D Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 7906200280 | |
| Download: ML19224B702 (2) | |
Text
-
% :,7 PfC,
,f UNITED STATES g
3
- 4. ' t NUCLEAR REGULATORY COMMISSION
') 1N h
WASHINGTON, D. C. 20555
- ' D ; 'i
'.'f j
i
% kt
/g
~?*
.".. 4 May 16, 1979 MEMORANDUM FOR:
D. G. Eisenhut, Deputy Director, Division of Operating Reactors D. K. Davis, Chief, Systematic Evaluation Program
.l{p/
THRU:
]
Branch, DDR
\\
FROM:
R. P. Snaider, Systematic Evaluation Program Brar.ch, DDR
SUBJECT:
FORTHCOMING t'EETING TO DISCUSS FURTHER WDRK RELATED TO SHIELD TANK NEUTRON DAMAGE Date & Time:
Friday, May 18, 1979; 9:00 a.m.
Location:
Room 6110, Maryland National Bank Building, Bethesda, Maryland
Purpose:
To discuss future work related to the determination of neutron damage (NDTT shif t) to PUR shield tanks, based on staff conclusion that aarlier flux assumptions are correct.
Participants:
NRC R. Klecker, W. Hazelton, R. Johnson, K. Hoge, B. Morris, S. Weiss, C. Serpan, F. Litton, R. Snaider NRL R. Hawthorne, et al BNL J. Carew, et al y,fS-Richard P. Snaider Systematic Evaluation Progrcm Branch Division of Operating Reactors cc:
See next page 295 13S 790620 0 A TO C
-e a
_,m-
=
DISTRIBUTION FOR MEETIliG fiOTICES fiRC PDR Central Files SEPB Reading fiRR Reading H. Denton E. G. Case V. Stello B. Grimes T. J. Carter T. Ippolito R. Reid G. Knighton V. Noonan D. Eisenhut A. Schwencer D. Ziemann D. K. Davis G. Lainas P. Check J. Scinto, OELD OI&E (3)
H. Smith R. Fraley, ACRS (16)
D. Bunch R. K?ecker W. Hazelton R. E. Johnson K. Hoge B. Morris S. Weiss C. Serpan F. Litton R. Snaider C. Hofmayer R. Hawthorne, NRL J. Carew, BNL R. Vollmer M5 i'36
.