Revision

/

10/25/78, 3.0 FOLLOW-UP ACTICQ I'PR 2 3.1 Announce-on page system - Reactor Trip 3.2 Initiate emergency boration per 2203-1.1 (Loss of Boran) if reactor power is not below 10% in 1 minute 3.3 Monitor make-up tank level and maintain level greater th an 55" 1

j by using Waste Transfer Pumps (WDL-P5A/B) and feed 1

rom an RCBT with boron concentration greater or equal to RCS 1

concen-tra tion.

3.4 Verify that the pressurizer heaters and spray have ret urned RCS pressure to normal operating pressure of 2155 psi 1

~

3.5 Reduce pressurizer level setpoint to 100" (25%).

l 3.6 Verify normal electrical lineup, i.e.. no substatio" 1

or in-plant distribution breakers are open (excer,t generator b reakers).

3.7 Check that all RMS channels are normal and that nplanned or uncontrolled radioactive release is in progress 3.8 Compute shutdown margin calculations per 4

2103 1 9 (Reactivity Balance Calculations).

If shutdowr. margin is le:s than 1".,

[

boron shuuld be added to the RCS.

3.9 If reactor start-up is not intended within four hour j

s raise OTSG level to 97-99% on the operating range using th 1

e feedwater valve bypass and tube sheet drens for level control 3.10 Fill out a Rector Trip report.

3.11 Notify H.P./ Chemistry to sample R.C. Letdown f or Dose Equivalent Iodine between 2 and 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> after power change of g reater than 15% within one hour period per Surveillance Prccedur i

e #2304-302.