ML19224B238

From kanterella
Jump to navigation Jump to search
Health Physics Procedure 1617,Revision 3:receipt of Radioactive Matls
ML19224B238
Person / Time
Site: Crane 
Issue date: 06/28/1977
From:
Metropolitan Edison Co
To: Mullinix W
NRC/IE
References
1617, TM-0083, TM-83, NUDOCS 7906140273
Download: ML19224B238 (6)


Text

'

N TMI DOCUMEffrS

~

DOCUMENT NO:

COPY MADE ON hN OF DOCUMENT PROVIDED BY I

/

METROPOLITAN EDISCN COMPANY.

Wilda R. Mullinix, NRC e

7906140273 194 09g e

~

1617 l' Ib LI 06 28/77 1/1/

TER (C'Oiry THREE MILE ISLAND NUCLEAR STATION STATION HEALTH PHYSICS PROCEDURE 1617

'O NOT REMOVE RECEIPT OF RADI0 ACTIVE MATERIAL Table of Effective Pages Page Date Revision Page Date Revision Pace Date Revision 1.0 06/28/77 3

26.0 51.0 2.0 11/05/75 1

27.0 52.0 3.0 08/04/76 2

28.0 53.0 4.0 08/04/76 2

29.0 54.0 5.0 08/04/76 2

30.0 55.0 6.0 31.0 56.0 7.0 32.0 57.0 8.0 33.0 58.0 9.0 34.0 59.0 10.0 35.0 60.0 11.0 36.0 61.0 12.0 37.0 62.0 13.0 38.0 63.0 14.0 39.0 64.0 15.0 40.0 65.0 16.0 41.0 66.0 17.0 42.0 67.0 18.0 43.0 68.0 19.0 44.0 69.0 20.0 45.0 70.0 21.0 46.0 71.0 22.0 47.0 72.0 23.0 48.0 73.0 24.0 49.0 74.0 25.0 50.0 75.0 Unit 1 Staff Recom nds A proval Unit 2 Staff Recom end A aproval Approval 1

Date Approval Date Cognizaft dgdt[Hepd Cognidnt Dh[. f{ead Unit 1 PORC R ommends Approval Unit 2 PORC Recommends Approval Date /o l/3l7'I 0'U lsulU Date b

W r

gge$hairman of PORC gjC6fChair a'n of PORC

/

PORC comments of -

included PORC comments of

- included (date)

(date)

By '

- Date -

By Date ly4 non W

Approvb e d -/ 7-

/

Station 9::7Im17endend ~

l "5 5-^

Unit Superintendent

1617 Revision 3 06/28/77 STATION HEALTH FHYSICS PROCEDURE 1617 RECEIDT OF RADICACTIVE MATERIAL 1.0 PURPOSE The purpose of this procedure is to describe requirements for receipt and acceptance of radioactive material.

2.0 DISCUSSION Several types of Radioactive Material could be received at Three Mile Island e.g., sources, contaminated liquids, contaminated tools and equipment.

The radiation protection personnel must insure that the shipment received has complied with Department of Transportation (DOT), Nuclear Regulatory Commission (N.R.C.) and Pennsylvania Department of Transportation (Penn. DOT) regulations.

3.0 REFERENCES

3.1 U.S. Department of Transportation Regulations Title 49 CFR, Parts 170-189.

3.2 10 CFR 20 3.3 Pennsylvania Department of Transportation Regulations 3.4 HPP 1602 3.5 HPP 1603 3.6 HPP 1604 3.7 HPP 1609 3.8 HPP 1618 4.0 EQUIPMENT 4.1 Film Badge /TLD and Self-Reading Dosimeter 1.0 fQQ e

1617 Revision 1 11/05/75 42 Portable Survey Instrument (alpha, beta-gamma or neutron) as required.

4.3 Smear papers and envelopes.

4.4 Protective clothine.

4.5 Survey Forms 5.0 OPERAT!NG INSTRUCTIONS 5.1 Receipt of General Shipments (All radioactive shipments except new fuel).

NOTE:

10 CFR 20 requires that packages of radioactive material delivered by a carrier to a licensed facility, or picked up at a carrier's terminal must be surveyed within three (3) hours.

5.1.1 The Radiation Protection Supervisor / Foreman and or Rad / Chem Tech /Jr. shall be notified immediately by the Met-Ed Storekeeper upon arrival of a shipment of radioactive material and its present location on site.

5.1.2 The Rad / Chem Tech /Jr. will proceed to the shipment location, and survey the vehicle, if possible, for radiation levels as follows:

5.1.2.1 Contact with external sur# ace of vehicle.

5.1.2.2 Three (3) feet from vehicle.

5.1.2.3 Six (6) feet from vehicle.

5.1.3 Record information on Vehicle Survey Record, Form HPP 1618-1.

-t 5.1.4 A Rad,ation Survey on the package will be taken~as follows:

5.1.4.1 Contact with external surface of package.

Jg 2.0

/

1617 Revision 2 08/04/76 5.1.4.2 Three (3) feet from external surface of package.

5.1. 5 A contamination Jurvey (swipe) of the package will be performed.

NOTE:

Steps 5.1.4.1 through 5.1.5 should be performed prior to unloading the package from the trans-porting vehicle.

5.1.6 Count the smear samples in accordance with HPP 1609 and record the results on HPP 1609-1.

5.1.7 If removable (loose) surface contamination in excess of 22,000 DPM/100 cm2 on the the package surface is found, the Rad / Chem Tech /Jr. shall immediately notify the Radiation Protection Supervisor / Foreman.

5.1.7.1 The Radiation Protection Supervisor / Foreman shall immediately notify 'the final delivering carrier and instruct the Rad / Chem. Tech /Jr. to survey the vehicle interior.

5.1.7.2 The Radiation Protection Supervisor / Foreman shall imediately inform station management for the purposes of notifying the Region I Office of the Nuclear Regulatory Commission.

5.1.8 If radiation levels are found on the external surface of the package in excess of 200 mrem per hour (mrem /hr) or at three feet from the external surface of the package in excess of 10 mrem /hr., the Rad Ctem Tech /Jr. shall immediately notify the Radiation Protection Supervisor / Foreman.

.]

5.1.8.1 The Radiation Protection Supervisor / Foreman. shall immediately notify the final delivery carrier.

5.1.8.2 The Radiation Protection Supervisor / Foreman shall imediately inform the Supervisor of Radiation Protection an hmi

~

~

3.0

1617 Revision 2 08/04/76 5.1.9 Complete the radioactive Material Receipt Form (See attached form 1617-1).

5.1.10 If applicable, record source number in the Radioactive Sources Inventory Log.

4.0 8

I

'. s 1617 Revision (

1617 r - *

~

n0/04/76 liETROPOLITAti EDIS0tl CC:tPA.'iY

~

~

~~

THREE fille ISLAtiD

~ ~~

~ '-

Radioactive Material Receipt Record Received From:

Carrier:

Date:

Type of Shipping Label O Labels Removed Identification:

Radiation Survey:

Radioactive Source Contact 3 ft.

_/

O Fuel Assemblies Contamination Survey:

O Other O rio significant contanination Technician Date REMARKS: (Pertinent data such as Fuel Assembly flo., etc.)

ACKil0WLEDGEMEtiT OF RECEIPT 2

1 Radiation Protection Dept.

flarr.u:

h.-

Date:

f g 10 orm 1617-1

~

5.0 i-6

)