09/13/76 THREE MILE ISLAND NUCLE AR STATION STATION HEALTH PHYSICS PROCEDURE 1602 I
0 NOT REMOVE RADIATION DOSE RATE SURVEYS Table of Effective Pages Pace Date Revision Pace Date Revision Pace Date R evision 1.0 01/19/76 2
26.0 51.0 2.0 09/13/76 3
27.0 52.0 3.0 09/13/76 3
28.0 53.0 4.0 09/13/76 3
29.0 54.0 5.0 09/13/76 3
30.0 55.0 6.0 31.0 56.0 7.0 32.0 57.0 8.0 33.0 58.0 9.0 34.0 59.0 10.0 35.0 60.0 11.0 36.0 61.0 12.0 37.0 62.0 13.0 38.0 G3.0 14.0 30.0 64.0 15.0 40.0 65.0 16.0 41.0 66.0 17.0 42.0 67.0 18.0 43.0 68.0 19.0 44.0 69.0 20.0 45.0 70.0 21.0 46.0 71.0 22.0 47.0 72.0 23.0 48.0 73.0 24.0 49.0 74.0 25.0 50.0 75.0 1 oval Unit 2 Staff Recom nds p Unit 1 Staff Recomm nds A proval Date Approval I
Date Approval f
t d
Cogniz$t dadfiegh Cognizan[02/t. i Unit 1 PORC Recommends Approval Unit 2 PORC Recommends Approval 0
n,, bal Date 9- ?- ?b M ate G
Chairman of PORC Chairman of PORC 7
included PORC comments of included PORC comments of (date)
(date)
By Date By
/Y/
Date
//& / 0 0 N f hf Z 0 U IS App 90 s
Statio/ Sup/rirdendent[/
/ I N 5 5'^
"4'
~.
Unit Superintendent 5
RPP 1602 Revision 2 01/19/76 THREE MILE ISLAND NUCLEAR STATION STATION HEALTH PHYSICS PROCEDURES 1602 - Radiation Dose Rate Surveys 1.0 PURPOSE The purpose of this procedure is to explain in detail how to conduct a Radiation Dose Rate Survey.
2.0 DISCUSSION 2.1 Dose rate is the radiation dose delivered per unit time.
2.2 The results of radiation dose rate surveys are used in the pre-paration of Radiation Work Permits so that adequate precautions may be taken to insure that personnel exposures are kept to a minimum.
2.3 Radiation dose rate surveys are conducted on a routine basis and whenever a specific need arises for both controlled and clean areas.
3.0 REFERENCES
3.1 Radiation Protection Manual Administrative Procedure 1003.
3.2 10 CFR 20 3.3 H.P.P. 1613 3.4 H.P.P. 1610 4.0 EQUIPMENT 4.1 Survey sheets filed in Health Physics Lab.
4.2 Portable G.M. Survey instrument.
4.3 Portable Ion Chamber j
4.4 Portable Neutron Detector 5.0 OPERATING INSTRUCTIONS 1.0
1602 Revision 3 5.1 Gamma or Neutron Survev 09/13/76
~
5.1.1 Select appropriate Gamma or Neutron detector and insure the instrument is calibrated and operating in accordance with applicable procedure.
5.1.2 Hold the appropriate detector at waist level when entering an area to be surveyed observing the meter indication, with the instrument on its highest range.
If no meter response occurs, turn the range selector switch to the next lower detection range until a meter response is noticeable.
NOTE:
When performing gamma surveys, the detector shield will be in the closed position.
5.1.3 Perform area su.vey at designated locations.
Note hot spots and record results on an area survey map as to where the readings were taken.
Record the reactor power level, in percent, on the survey map.
Survey maps for all areas of the plant are available as per Item 4.1.
5.1.4 If the survey is being conducted for a RWP, take a general area survey and readings on all equipment to be worked on in the immediate area.
5.1.4.1 When performing a survey in a noble gas environment (Xe-133, Kr-85, etc.) for purposes of determining stay time calculations for a Radiation Work Permit (RWP), a reading will be taken with the detector shield open.
5.1.4.2 The value determined in 5.1.4.1 will be used to calculate a stay time as shown in Example 6.2.
3 5.1.5 Record all readings on area survey maps, indicating " hot spots," where applicable, and circle contact readings.
See Figure 1602-1 for an example.
188 202 2.0 O
i HP 1602 Revision 3 09/13/76 NOTE:
Ensure that the area is properly posted per HPP 1610.
Record the reactor power level, in percent, on the survey map.
5.1.6 Forsard the completed area survey map to Radiation Protection Supervisor / Foreman for approval.
5.2 Beta Survey 5.2.1 To conduct a Beta survey, use the Rad Owl-2 in the following manner.
5.2.2 Enter the area to be surveyed with the instrument on the highest range.
5.2.3 If no meter response is observed, switch to a lower range until a meter response is noticeable.
5.2.4 Close the beta shield on the base of the instrument and take a reading.
5.2.5 Open the beta shield on the base of the instrument and take a reading.
5.2.6 Take the shield closed reading obtained in step 5.2.4 and subtract it from the shield open reading obtained in step
- 5. 2. 5.
5.2.7 Take the remainder obtained in step 5.2.6 and multiply it by the Beta correction factor found posted on the side of the instrument. The resulting number is the beta exposure.
5.2.8 Record all readings on area survey maps, indicating " hot spots" where applicable and circle contact readings.
Beta readings are to be identified by the letter "B" placed after the appropriate reading.
3.0 188 203
1602 Revision 3 09/13/76 5.2.9 Ensure that all areas are properly posted per H.P.P.1610.
6.0 EXAMPLE
~
6.1 Beta Dose Calculation i
100 mrem /hrOpEnWinQwReading
- 20 mrem /hr Closed Window Reading 80 mrem /hr 80 mrem /hr x 3.2 (Beta Cor. action Factor) = 256 mrem /hr Beta 6.2 Stay Time Calculation In A Noble Gas Environment Beta Dose Calculation = 256 mrem /hr Beta Stay Time = 300/256 = 1.17 hours1.967593e-4 days <br />0.00472 hours <br />2.810847e-5 weeks <br />6.4685e-6 months <br /> Based on 300 mrem / week whole body administrative limit for a 40 hour4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> work week.
e
~
188 204 4.0 l
g n
$1u$= M.
O i
s d
g a
O3wDm n
e i
R da a
e e
R r
s A
t NS c
WR l
a OE a
t D L r
n TO e
o EO n
C LC e
P G
M U
S
/
/
-4
/
I T
N N
A E
M C
U I
N E
R 4
E H
T T
A M
S C
E i
I N
D T
I T
5 3
N S
R R
P O
C 3
O M T R
T M A A
\\
g A
A n
R R
E E
E E
T 5
T I
SN J
St E
I1 2
E T'-
L 9
G 7
2 E
0
/
(5 V.
E L
7(
b E
T K R
N N
]
A
.N O
A A A N I
B O
f L
]
T
,E E A
L O
9 R
5 F
T O N C AI p
G S
D 2
/
3 XR N
P RD XIAM T
n R
N RU
[LI R
i A N D P
,E P
l G
OAM e
Y N
. =RCDP XOR U v
TA e
NH L
LX r
3 e
OE w
OT o
CA P
X E R H ro N
I t
A ca R
e D
R R
H S
/
G p
R g
N a
M I
n M
D i
N A
y d
I E
u.
e a
S e
G R
v R
r N
T s
u I
C a
t D
A S
A T
e a
E B
N e
R O
r a
A C
A e
M L
r L
i l
h A
a A
c
,oO E
l i
cC A
C p
a L
r y
T e
T R
n E
I e
B C
G
- .O ol, g8-
.