1662 Revision 2 12/05/77 THREE MILE ISLAND NUCLEAR STATION M ASTER CO DO NOT REVOV~

STATION HEALTH PHYSICS PROCEDURE 1662 COLLECTIOil 0F EflVIRON!'EllTAL RAlt; WATER SAMPLES CONTRUi_uo copy Table of Effective Pages g

Date Revision Pace Date R evision Pace Date Revision 1.0 05/31/77 1

26.0 51.0 2.0 09/09/76 0

27.0 52.0 3.0 12/05/77 2

28.0 53.0 4.0 12/05/77 2

29.0 54.0 5.0 30.0 55.0 6.0 31.0 56.0 7.0 32.0 57.0 8.0 33.0 58.0 9.0 34.0 59.0 10.0 35.0 60.0 11.0 36.0 61.0 12.0 37.0 62.0 13.0 38.0 63.0 14.0 39.0 64.0 15.0 40.0 65.0 16.0 41.0 66.0 17.0 42.0 67.0 18.0 43.0 68.0 19.0 44.0 69.0 20.0 45.0 70.0 21.0 46.0 71.0 22.0 47.0 72.0 23.0 48.0 73.0 24.0 49.0

/4.0 25.0 50.0 70.0 Unit 1 Staff Rece enc,

> proval Uni 2 Staff Reco endsgAp' royal

!/b Date Approval Date

".p;i. 'al I

i Cognil anb94p/ Hehd Cogni[n ej pt Unit 1 PORC Recommends Approval Unit 2 PORC Recommends Approval b

ZYA> t >

Date // *bl'D 0*

Date l

~

~ y, Chairman of PORC V/ C%irmadof PORC PORC comments of included PORC comments of included (date)

(date By Date By ae ApprovaC k/

n, //4,)

Date/7/> Y Approval Date Approval

)/ dbW Date /M/-7/77 Mgr. 0perational 9

(/

//

Quality As:urance Unit Superintendent

1662 Revision 1 05/31/77 THREE MILE ISLAND NUCLEAR STATION STATION HEALTH PHYSICS PROCEDURE 1662 Collection of Environmental Rainwater Samples 1.0 PURPOSE The purpose of this procedure is to describe the method of collecting the routine rainwater samples in the environs of TMINS.

2.0 DISCUSSION In accordance with the TMINS Environmental Technical Specifications, Table 3, rainwater samples are collected monthly from the environs of TMIt'c and sent to an outside vendor for the required analyses.

Stations and Collection Frequency TM-RW-15G1 Monthly West Fairview TM-RW-7F1 Monthly Marietta (Dragers Farm)

TM-RW-5Al Monthly Observatien Center TM-RW-8Cl Monthly Falmouth Collins Substation Each collection system consists of a collecting funnel 12h" in diameter which is connected to a five gallon plastic jerry can by tygon tubing.

At each station the accumulated rainfall is collected.

Normally only the one gallon prelabelled jugs arc taken into the field.

Standby five gallon jugs are taken for each station if freeze-up of the field jugs is a possibility.

C:; TION: At no time during the sample collecting procedures shall the sample collector or anyone accompanying him wear a tritium dial wrist watch.

l

3.0 REFERENCES

3.1 TMINS Technical Specifications, Appendix B.

185 310 3.2 HPP 1660.

1.0

~

W

1662 Revision 0 09/09/76 4.0 ECUIPMENT 4.1 Four (4) new one gallon sampling jugs.

4.2 One (1) Sample Receipt Sheet (Form 1662-1).

4.3 One (1) Sample Collection Sheet (Form 1660-1).

4.4 Sufficient cartons to ship the collected samples to Contractor Laboratory.

4.5 Indelible marker or equivalent, pens, pencils, tape for sealing cartons.

4.6 Four (4) spare prelabelled five gallon jerry cans; one for each station (during persistent freezing weather).

4.7 Preaddressed labels.

5.0 OPERATING PROCEDURE At each sample location:

5.1 Disconnect the tygon tubing from the jerry can, shake the can, completely empty the contents into the toilection jug (or fill the jug and dispose of the excess), and then cap the jug.

5.2 Reconnect the tygon tubing to the jerry can.

5.3 Label the jug, con.plete the appropriate section of the Sample Receipt Sheet and Sample Collection Sheet inclum.ng:

5.3.1 Dates of sample period, time of collection, and sample code.

NOTE:

Enter the time under " Comments" column.

Sample start date may be found on data sheet inside air particulate scmpler.

5.3.2 Approximate quantity of sample.

5.3.3 Any unusual conditions; e.g., algal growth in jerry can, etc.

5.3.4 Enter date of rain collection on the data sheet inside the Air Sampler.

185 3! !--

2.0 O

e

1662 Revision 2 -

12/05/77 5.4 If can contents are frozen, exchange the can with cre of the standby L

cans and pour the collected rainfall into the collection jug after it thaws.

5.5 Packaging and Shipment.

5.5.1 Package and ship the samples to appropriate off site vendor by United Parcel Service.

Ship the completed and signed Sample Receipt Sheet in the envelope with the samples and mark the envelope accordingly. The requiremer.ts for shipping by United Parcel Service are available in the Unic One Warehouse.

5.5.2 Sample shipping labels si. auld contain the following information:

To.

(Address of Vendor)

Attention:

Sample Coordinator From:

Three Mile Island fluclear Station P. O. Box 480 Middletown, Pennsylvania 17057 5.6 Administrative Procedures 5.6.1 When the sample collection is complete, the Sample Collection Sheet (1660-1) is distributed at follows.

Original to Radiation Protection Specialist, Reading One copy to Radiation Protection Supervisor One copy retained by Sample Collector 5.6.2 Tha Radiation Protection Supervisor shall rcview the sample collection sheet for completeness, note any problems requiring corrective maintenance, and file the copy in the Radiation J

Protection Department file.

185 312_

l 3.0

1662 Revision 2 12/05/77 To Be Mailed With Samples FORM 1662-1 TMI - RADIOLOGICAL Ef4VIRONMENTAL MONITORING PROGRAM Samole Receipt Sheet Precioitation MCNTHLY vet; DOR STATION DATE DATE SAMPLE COMMEitTS LAB NO.

CODE START STOP QUANTITY VOL TM-RW-7F1 Ma rietta TM-RW-5Al Obs. Center TM-RW-8Cl Falmouth Collins Sub.

TM-RW-15G1 W. Fairview Approved Metropolitan Edison Company Collected By Delivered By Received By Date Received 3oc 717 iUJ JlJ e

4.0

-