50-320 On Site Ground Level Surveys without GE Gride Cata 3/30 - 4/3 79061302co Iq~

179 198

f

'^g e,

4-3-79 R212 LICENSEE ON-SITE DATA Reading (mr/hr)

Time location Betagamma Gamma 0305 north of MDCT 0.6 0.2 0311 east of MDCT 0.7 0.3 0315 south of MDCT 0.5 0.15 0318 west of MDCT 0.2

<0.1 0312 SSE-11 0.04 0.02 0326 top MDCT, north end 0.6 0.1 0333 top MDCT, south end 3

1.4 0334 SSE-11 0.1 0.02 0338 SSE-21 0.06 0.02 0400 SSE-41 0.15

!;l;!,

~

W

I

i jj j 2.1 4-3-79 R-211 LICENSEE ON-SITE DATA Reading (mr/hr)

Time Location Beta Gamma Gamma 0116 west of unit 2 "A" NDC1' 3

0.8 0122 north of unit 2 "A" NDCT 1.4 0.4 0121 SE-01 0.04

<0.02 0127 south of unit 2 "A" NDCT 0.3 0.15 0128 WSW-31 0.08 0.02 0129 E-01 0.06

<0.02 0130 cast of unit 2 "B" NDCf 0.3 0.15

/135 south of unit 2 "B" NDCT 0.5 0.2 0139 west of unit 2 "B" NDCT 1.4 0.5 0145 WSW-11 0.08 0.02 0146 north of unit 2 "B" NDCT 2

0.7 0152 WSW-21 0.08 0.02 0153 ESE-01 0.06

<0.01 0208 SE-6 6

2 0200 SEE-01 2

0.2 0202 SW-1?

0.03 0.01 0215 SE-5 11.5 4

0213 GE-7 10 s

0229 SE-01 0.03

<0.01 0233 SSE-01 0.02 0.01 0235 GE-6 0.5 0.1 0237 GE-5 0.25 0.1 0238 SSE-11 0.09 0.01 i;9243 south of unit 2 "A" NDCT 7

2 kL)244 500 KV substation 0.03 0.01 N

CD CD

v

(;=-

fr -

a-h a6 ncaanas T07" R216 CONTROL NO.

DATE: 4/3/79 LICENSE ON-SITE DATA READING (mR/hr)

LOCATION TIME (ESTl

<0.1 Control Room 70 0900 RC Evap Control Panel _ _

Out of Service North Fuel Handling E: idge Out of Service '-

' ~ ~ ' ~

0900 Equi? ment Hatch 16

~

Fuel Handling Bridge 60 Aux Bldo Access Corridor Col 60 0900 Rx 31cg Purge Unit Area

<0.1 0900 Cable Room 4000 Makeup Tank Area Out of Service Fuel Handlina Bridge South Cut of Service 0900 In Core Instrument Panel Area 70 0900 Waste Discosal Storage Area Out of Service Atax Blag Access Corridor Col Out of Service 0900 Aux Bldg Unit Exhaust Area 40 Rx Bldg Cooling Pump Area 70 Interwell Coolina Puma Storage Area 4

0900 Personnel Access Haten 45,000 R/hr Cut of Service

'0900 Rx Bldg Dome Aux Bldg Sump Tank Filter Rcom 0.4 0900 Control & Ser Bldg Corridor 120 Fuel Handle Bldg Exhaust 179 201

I

!i;;?I!

i iiiilJ c

4-2-79, 4-3-79 R-211 LICENSEE ON-SITE DATA Reading (mr/hr)

Time Location Deta Gamma Gamma 2110 S-01

<0.02

<0.01 2136 SSE-01

<0.03

<0.01 2144 SSE-11

<0.03

<0.01 2145 S-31 0.02 0.01 2145 S-32

<0.01

<0.01 2200 S-21 0.02

<0.01

,.2200 SSE-21

<0.03 0.01

'(3 ?209 SSE-11

<0.04 0.01

2218 SE-01

<0.03 0.02 2328 SW-11 0.55 0.07 2343 WSW-11 0.03 0.01 2356 SW-11 0.04 0.01 2330 North of MDCT 0.8 0.2 2330 top MDCT south end 8

3.5 2330 west of MDCT 1.3 0.3 2330 east of MDCT 4

2 2330 south of MDCT 3

2 2330 north end of MDCT 1.6 0.5 0019 SSW-21 0.3 0.05 0021 SE-9 0.8 0.2 0026 SE-8 1.5 0.2 0042 SSE-01 0.02

<0.01 0046 S-31 0.01

<0.01 ajS051 SSE-11 0.02

<0.01

' dido 56 SE-11 0.3

<0.01 0057 SSW-21 0.04 0.02 0103 - -

ESE-11 0.03

<0.01 0113 sa SW-21 0.06 0.01 w

N C-')

PO

!!1 f

si:

'E

,- u Jf ;

v 4-/-79, 322c:8-R-248 LICENSEE ON-SITE DATA R-208 R-208A location Time MR/HR Time NR/IIR Control Room 2045

<1 2215

<.1 RC Evap Controe Panel 2045 60 2215 60 North Fuel Handling Bridge 2045 out service 2215 out service Equipment Hatch 20'.5 out service 2215 out service Fuel Handling Bridge 2045 6-8 2215 6 JP Aux Bldg Access Corridor Col 2045 40 2215 40 2045 60 2215 60 l'..Rx Bldg Purge Unit Area Jable Room 2045

<.1 2215

<.1

' Makeup Tank Area 2045 3,500 2215 3,500 Fuel Handling Bridge South 2045 out service 2215 out service In Core Instrumnt Panel Area 2045 out service 2215 out service Waste Disposal Storage Area 2045 10 2215 7

Auz Bldg Access Corridor Col 2045 out service 2215 out service Aux Bldg Unit Exhaust Area 2045 out service 2215 out service Rx Bldge Cooling Pucp Area 2045 40 2215 35 Interwell Cooling Pump Storage Area 2045 60 2215 60 Personnel Access Hatch 2045 4

2215 4

40,000R[4jg 2215 40,000 R//ec

~

Rx Bldg Dome 2045 Aux Bldgs Sump Tank Filtr Room 2045 out service 2215 out service Control & Ser Bldg Corridor 2045 4

2215

.35 Fuel Handle Bldge Exhaust 2045 100 2215 ggi/Ao

.~

Q:'

N 4

N Ou

I r

h

/

r e

e r

e e

e e

h e

f cf c mf cf c f cf c

/f c r

1 oioi5 1

oioi oioi R oi3 v

v

.0 v

v v

v v

h

/

00t rt r1 0000t rt r0t rt r0 050t r00 F

R 7 ueue 45 5 ueue1 ueue4 7

0 ue 2

m m

OSOS

< 3OSOS OSOS 0,O S 1

b 4

imo 0

0

,J 2

4 9

R 7E

/ L e

555 5

555555 5

55 5

5 5555 55 3I m

555 5

555555 5

55 5

5 5555 55

/ H 444 4

444444 4

44 4

4 4444 44 46 T

11 1 1

1 1 1 1 1 1 1

1 1 1

1 11 1 1 1 1 r

h r

e e

e e

e e/

h e

f cf c f cf c f cf cr

/f c r

oioi3 1 0oioi oi oi m R oi2 h

1 v

v 0

v v

v v

v.

t rt r00000,t rt r8t rt r0 050t r00

/

45 ueue ueue4 6

0 ue 1

R P0ueue m

sOSOS 4OSOS OSOS 0,O S 1

3 0

0 2

4 R

e 555 5

555555 5

55 5

5 5555 55 m

000 0

000000 0

00 0

0 0000 00 i

999 9

999999 9

99 9

9 9999 99 l

000 0

000000 0

00 0

0 0000 00 r

e e

e e

e e

h e

f cf c f cf c f cf c

/f c r

1 oioi3 1 0oioi oioi R oi3 0

v v

v v

v h

v v

/

00t rt r00000,t rtr8t rt r0 050t r00 R

5ueue 57 ueue ueue5 7

0 ue 5

A m

OSOS

<4OSOS OSOS 0,O S 1

T 2

A 0

0 D

2 4

E R

T I

e 000 0

000000 0

00 0

0 0000 00 S

m 555 5

555555 5

55 5

5 5555 55 i

666 6

666666 6

66 6

6 6666 66 l

000 0

000000 0

00 0

0 0000 00 N

O E

r E

e e

e e

e e

h e

f cf c f cf c f cf c

/f c N

r 1

oioi3 1 0 oioi oioi R oi2 E

E v

v 0

v v

v v

v rt r8t rt r0 050t r00 C

/

00t rt r00002,t 58 ueue ueue5 8

0 ue 8

I R

0 ueue L

m

<1 OSOS

<4OSOS OSOS 0, O S 1

1 0

0 2

4 R

e 555 5

555555 5

55 5

5 5555 55 m

222 2

222222 2

22 2

2 2222 22 i

444 4

444444 4

44 4

4 4444 44 T

000 0

000000 0

00 0

0 0000 00 l

l o

ao r

e C

h eC a

o g

t r

e a

d d

r u

a Ar r

e it oa o

e o

A r

rs ir d e S

r ed Ap h

ru l B i r A

gi t

m c

oa e

era e

ar s

pu t

Ch ng gr g

l rr u

mP a

x an dot o

e oo a

u k

gE l

f i!

Pi i Ci i

n tC h

P g n

d n-l r

n ar a

S x

n s

a l g I;M i

l d h

BsU eB P

s E

gi s

T Bd on c

s r

l s nl ae l

oec pmrB

.I i

ra t

gea Ag r

ae t

i l

mt K a

ncg n

t sc i

orce moe on i cr ki s

oc n

CAAmuoS e l

f Aumnl n

pA U

o oSR l

l I

ool l

i' RCe t

d Poad I

s Cl eld

&d n

u n

ng oTn i g g

l ge gr n

i: i 9

i oa m

lad gR a

e Dd d

g e a n gd el a o

l pF e

l d pl r

l l

d wrndl t oH l

l 7

t rvh p

Bl eu o

eB B

l rool Bl r

/

a tEt i

l Bl el C

t B et sB itl 2

c n

r u

ex bk e sx x

tSr xF ne

/

o oC o q

uuxaau n

au u

xn exu ou 4

L CRN E

FARCMF I

WA A

RI PRA Cf I

i

!i I-i

}3 l

J

.Ih

- d )4

[} 4 I4

I 7'

C P

R a

121 1 22 11 n

1 61 25881 5200000025 00 i

)

m r a 1

61 121 h

G

/

Rm

(

s a g

m n m i

a 541 3 2

1 2 358 5385000010 100 d

G 21 1 1 a

e a 1 31 63 452 R

t e

A B

'r.

D E

T I

S N

T O

C D

E M

E S

e N

v E

o e

C b

s I

a n

u L

o o

H e

i

'0 t

su 5

a 4

t WTo s

Ch i:

r b

.D e eT u CMr i

n tCS a

o pD IIW oHV 11 II 1 1 i

t 0c K1 01 h01 i -

0 - - 11 ttt - -

234567891 i

a 1

c l

0 - EE10iiuEE o

EEEEEEEEEE eW8ESS - - nnoSS L

SSSSSSSSSSHS5SSSSSUUSSS 9

7

/

e 00000000000008990000090 2

m 1 1 11 1 1 1 1 113355002333352 77777777776777888888890

/

i 4

T 111111111111 11111 1 11 11 2 i.

i il l

i 1

ae NCL

._ s DT

,,j j

,s

v

~

Licensee On-Site Data R-200

,p Readings (mr/hr)

Time Location Beta Gamma Gama 1300 SE-7

.2

<.1

=

1302 SE-8 3

.3 1312 SE-9 2

.4 1315 SE-8 1

.2 1331 SE-8 1

.1 1336 SE-8 1

1 1340 SE-8 2

.35 1345 SE-7 1

.2 1356 SE-7

<.01

<.01 1404 SE-9 2

.4 1406 SE-8 1

.1 1410 SE-10 1

.1 1415 SE-9 2

.3 1420 SE-8 1

1 190 SE7 7

.bl 1445 SE SE-10 2

.4 1455 SE-8 to SE-9 2

.3 1455 SE SE-8 1

.1 1455 SE-8 2

.3 1504 SE-8 3

.4 1506 SE-8

.5

.25 1524 SE-8 3

.4 E

1149 W-ll

,3

,05 1229 W-ll

.2

<.0) 179 206

2 9

R-200 Licensee On-Site Data Readinas (mr/hr)

~ ~

Beta Gamma Gamma

~~

Time Location

<.1

<.1 1230 Observation Center b..

20 1329 South Tower Screen House

.3

.01 1332 W-il 14 1335 500' Above Screen House 1.5

.1 1344 W-11

.1

.01 1353 W-11 0

1358 W-il

.01

<.01 1413 W-il

<.1

<.1 1416 North End of Bridge on Island

.03

.01 1425 W-ll to NW-21 14 5

1432 58' N of Screen House

<.1 0840 North Gate

.2 0840 Unit 1 River Water Screen House 1.2 0840 Mechanical Draft Cooling Tower

.1 0840 South Parking Lot

<.5 ud40 In between Unit 2 Cooling Towers

<.1 0850 In between Unit 1 Cooling Towers

.05 1020 North Gate

.1 1020 North Bridge

.05 1020 Weather Tower

.2 1020 Warehouse

.3 1020 River Water Screen House 1

1020 Mechanical draft Cooling Tower 179 207

3 Licensee On-Site Data R-200 Readings (m-/hr)

=.._..

Time Location Beta Gamma Gamma

.._ x-1020 Soutn Parking Lot

.1 UI

__7

_.7_.,_

1020 Unit 2 Cooling Towers

.05

-=

1020 Unit 1 Cooling Towers

.05 1455 NW Corner Warehouse 1.7

.8 1455 200' N of Screen House 3

1.8 1455 50' N of Screen House 3.5 1.5 1458 W-il

.02

<.01 1525 W-ll

.05

.01 1600 WSW-ll

<.01

<.01 179 208

lI..

(

Licensee On-Site Data 7,

Date:

4/2/79 R194 Time Location Reading (MR/HR)

Beta Gamma Gamma 0353 Observation Center 0.1 0.1 0357 between WNW-ll and W-ll 0.2 0.07 0354 E-ll

<0.1

<0.1 0405 NE-Il

<0.1

<0.1 0409 W-ll 0.7 0.13 0410 aoe'NNE-11

<0.1 0418 0.2 Miles N at Goldsboro 1.1 0.1 C421 N-21

<0.1 cG2S (A. ' O W ' 'l Y. 2 4 o,9 cg o w

/I o'&

y 179 209

(.

(

a.

Licensee On-Site Data '-

Date:

4/2/79 R193 Time Location Retdina (MR/HR)

Beta Gamma Gamma 0119 W NW-ll

.14

.03 0135 S SE-01

<.01 0144 S SE-ll

<.01 0205 W NW-ll 0.02 0.01 0235 W NW-ll 0.06 0.02 0300 W-ll

<0.5

<0.1 0303 SE-ll

<0.1 0311 55'11

<0.1 0315 between W-11 and W NW-11 0.5 0.05 0323 between W-il and W NW-ll 0.3 0.03 0323 Observation Center

0. 5 0.5 0331 E SE-ll

<0.1 D334 Observation Center 0.1 0.1 0349 between W-il and W NW-ll 0.6

0. 1.

i79 2lg

-r

[

License On-Site Data (Continued)

 ; E Date:

4/1/79 R194 Time Location Reading (MR/Hl'l Beta Gamma Gamma 2100 W-21

.05

.03 2110 W-ll

.02

.01 2110 Entrance to South Bridge

<.1 2125 N NW-11 1.0

.2 2119 South of Unit 2

<.1 2138 N NE-01

<.1 2140 N-ll

.1 2141 W NW-21

.02

.01 2156 NW-21

.02

.01 2230 NW-21

.02

.01 2226 NW-31

<.1 2226 NW-21

<.02

.01 179 211

L..-

Licensee On-Site Data Date:

4/1/79 R194 Time Location Reading (MR/HR)

Beta Gamma Gamma 1821 SE-6

.3

.03 1826 between W SW-ll and SW-il 1.5

.3 1821 SC-2

.04

.02 1821 SE-3

<.01

<.01 1821 SE-4

.04

.08 1821 SE-5

.02

.03 1821 SE-6

.03

.03 1823 S SE-01 and SE-01

<. C[1

<.01 1830 between SW-il and W SW-ll 1.7 0.2 1840 SE-01

<.1

<.1 1830 400 ft. over Shelly's Island 5

1924 E-01

<.1

<.1 1930 E NE-01

<.1

<.1 1934 W NW-ll

.02

.01 1940 NE-01

<.1

<.1 1937 N NE-01

<.1

<.1 1949 E NE-01

<.1

<.1 2010 E-11

<.1 y

2017 W NW-21

.01

<.01 2015 ESE-11

<.1

<.1 2025 SE-ll

<.1

<.1 2033 S SE-11

<.1

<.1 2030 Yocum Town an Rt. 392

<.1

<.1 2044 W-31

.1

.04 2012 Unit 2 North of MDCTC 500 ft.

4.0 2023 600 ft. over Shelly Island -

West of Unit / 2-Semon House 5.0 h$$h?

tL i

i

()

Un t;fv /?'l L#

ll LICENSEE ON-SITE DATA R176 -Bidinger Date:

4/1/79 Page 1 of 2 Reading (mr/hr)

Time Location Beta-Gamma Gamma 1420 SSE-01

1. 5

.1 1436 SSE-11 1.0

.2 1433 SE Corner CT by GE-6 7

3 1452 SSE-11 2

.2 1456 W of GE-G 6

2 1300 Brunner Island

.7 1503 Gate 2

.8

.3 1503 West of GE-6

2. 5

.5 1517 Gate 2 1.2

.5 1531 South Unit 2 NDCT's

.4

.2 1540 SSE - 01

<.1

<.01 1554 S-01

.3

.1 1554 S-11

.3

<.1 1618 SSE-01

<.01

<.01 1518 S-01

<.1

<.1 1626 SSE-11

.02

<.01 1629 Construction Gate 2

.8 1628 SE 8 1.4

.4 1628 SE 9

.4

.3 1628 SE 10

.2

.1 1628 SE-1

.1

.1 1628 SE-7 1

.4 1628 SE-6

.7

.3 1628 SE-5

.5

.3

-- 1628

't-3

.2

.1 1628 SE-3

.2

.2 1628 SE-4

1. 2

.5 1615 Const. Fence SW Corner

<.1

_l548 Const. Fence

.5

.2

~Jf51 S-11

<.1

<.1 sd556 GE 8, 10 yd South 5

2 1657 SSE-11

<.1

<.1 r4E58 W-11

.02

.02

-1553 S-11

<.1

<.1

'1902 SE-11

<.1

<.]

I ii g.

.............J!

5i Date:

4/1/79 Page 2 of 2 Reading (mr/hr)

Time Location Deta-Gamma Gamma 1710 WSW-11

.02

.01 1712 ESE-11

<.1

<.1

,1715 W-11

.02

.01 1722 ENE

<.1

<.1 172F E-01

<.1

<.1 1746 Rt 441 of South Bridge

<.1

<.1 1748 S-11

<.1

<.1 1750 S-01 AL 1.. I c-D1 /-.. I 1752 South Parking Lot

.2

<.1 J 1755 SW corner south parking 1

.3 fence 1759 SW-11 1

.2 1810 SE-1

.1

.04 1811 SE-9

.6

,1 1812 South Parking Lot

.2

<.1 1813 SE-8 3

.4 1814 SE-7

.9

.1 1818 SSE-11

<.1

<.1 19.ro G) - Ii 0O' L**

I L'l A'I I4 3o co-It 19 9 tl w.- o,

L.n L. I li 'l o stE -o /

L.l L.\\

l9 39 Je' -o f L. I L.I

~<

TN)

t-ip i.,

V R 197 Licensee On-Site Data 192 b Time Location Reading (MR/IIR)

Deta Gamma Gamma 2100 W-21 0.05 0.03 2100 W-11 0.2 0.1 2110 Entrance to South Bridge

<0.1 2125 WNW-11 1.0 0.2 2119 South Unit 2 cooling tower

<0.1

~

2138 NNE-01

<0.1 H

2140 jM'11 0.1 2141 WNW-21 0.02 0.01 2156 NW-21 0.02 0.01

'f200 GE-1n

-5

u. / -

2210 CE-3 it-0.1-2311 WNW-11 1

0.5 2317 NW-21 0.01 0.02 2340 WNW 11 0.7 0.2 4-2-79 0020 SE-01

< 0.1 i

t 9024 SSE-11

<0.1 0026 SE 11

<0.1 0033 ESE 11

<0.1

[]j 0036 W-11 0.02 0.01

~

r

i':

.I a'

._..a, M

6 i

DATE:

4-1-79 CN-SITE DATA R-158 TIME (EST)

LOCATION READING (mR/hr)

Beta-Gamma Gamma 0905 Unit II Cooling Tower A East 10 3

North 30 5

South 8

2 West 0.1 0.06 Unit II Cooling Tower B South 0.4 0.1 East 4

0.9 North 4

0.3 West 4

0.9 0944 800' From Unit II Reactor aldg 8

4 0956 South Bridge

<0.1

<0.1 M

NO N

% *J

~_.-

.m; I

4 i

s M

O N

M Q

Q bi 7 C

C C

a C

O O

\\C M.1

.I

%eA m

g g

7 T

N 9

C C

.A O

N N

N i

s

_1 O

O N

o e*

c a

4 C3 C

Z C

6 6

2 u

V U

C C

=,

-O o

C 1

1 p

6

~

6 6

_C m

e e

I N.

a==.

S-s x

.a

-o 0

0 m

=

O O

O O

C C

O C

Q 179 217 f

f

t e

g

,,,%~.

,b.,w-

= em

~

es h?m W

m b

m g

O C

C Tl O%

6 o

o e

o cs v

$a D

a

=

c: -

'O k, h N

N c

a o

o o

e d

, b O

b b

~

v

=a 4

C e

a=e

[

e 2

C C

E, m

M N

m M

t M,

w W

  • y e

e 4

8 5l 3

W 3

W W

I N

6 m

6 yl O

d6 O

ag m

.- }

N m

W D

l o

o C

C

~

y f

N O

l A

il 8

I t

ut

,- A W

4 OAlt: J/31/19 R144C ON-SilE DATA (1-?31/133)

IIME 10 Call 0N CONCINTRAll0N pCi/ml 9

-10 12:30 GE-3 1 - 131 - 1,55 x 10

-10 14:24 NE-01 I - 131 - 1. 3 3 x 10 13:13 Observation Center 1 - 133 s(1.3 x 10'II C

N 3-

._s i

i

, '/

j jpykt RI444-K L

DAIE; 3/31/79 a

ON-Slif DATA U

e I

Rf AO NG a,R/hr TlHE LOCATION t!E T A-G AMitA GAttHA 1515 SE-3 40 12 1515 SE-4 3

<0.1 1520 Northgate 0.2 0.2 1520 Observation Center 2

0.5 1538 NE-01 0.15 0.03 1536 NE-Il 0.04 0.01 153u NE-Il

0. 0 %

0.01 1538 NNE-11 0.05 0.01 1538 LNE-Il

0. 3 0.05 1538 NE-21 0.04 0.01 1550 Entrance to 500 Ku substation 8

11. 7 1658 E5E-21 0.08 0.02 1/00 E5E-Il 0.01 0.01 1700 SE-01 3.5 0.5 1700 SE-II 3

0. 4 1700 SE-21 0.05 0.01 1749 East U-2 NDCT #8 18 0.03 1749 East U-2 NDCT #A 30 ti 1810 North Cate 0.05 0.01 1810 NNE 0.01 0.01 1810 NNt-01 0.01

<0.01 1810 Cooling Tower East 2

P.2 1810 Observation Center G

0.6 1810 NE-Il 0.05 0.01

.,,)

1655 NNE-01 0.5 0.3

'"C) 1915 Observation Center 0.5 0.2 1925

[NE-Il 0.4

<0.1 N

N CD S

i,

'e

,t n

,y 4

t i!

FJ I

e i, I

,e 9

7 t0 u, 3 t

3 e

u,

l5

^

a1

^

v6 e

0 v

le o

,t) t aw t

a a

o ndi e

s oe t

k i t '

o ms tf r

n sf e ere e

u es e

Ri Qv(

t s

1 r

n h

a

/

l R. t s naI 0)f 10ao m

r e

oad t gi r

r s

r h

h r

ra h

/

r

/

h htt g

/

r r

R h

R,

/

/ es n

R h

h i

R n

/

p R

Rt;e

/ /

i 0

R.

R 0

m I

0 2

m(W d

0 a

0 n

m 0

0 e

0 0

0 0

R 5

8 0

5 5

0 s

esae le R

A __

T.

ro k.

A _.

r D

t a

IE_

i l

m T

t u

y n

n a

S w

c C_

s e

N a

s D

'r r

e t

s s

e a

n G

I f

e t

s n

a e

o d

i W

i t

s a

t h

r u

c o

o t

p a

a t

h va n

ee e

s a

r m

s e

t a 2

s n

e r

n a

c e

m ie i

c a

lon o

a al r

t a

k n

r oa o

d i

o l

a cp R

n n

c e

t u

o n

rl l

o i

f n

p oo o

B t

o o

u t r r

a e.

s e

ct t

e e

c p

r k

an n

n o

m r

t o

e a

e o.

o o

I D

t p

n r4 C

D i

S

)

9 7

)

9 d

7 2

/

0 1

3

}

/

(

M m 3

Q p

0 5

0 d

9 0

e e

1 4

0 0

5 0

1 t

m 1

6 2

8 1

4 a

0 0

0 1

1 o i s

T C

J

'A I

I

}

_Oti-S I T E D A_T A_

q Date: 3/30/79 I

i lhe..Il5 I_}

l(>'] tion instrament Readig R.maras r

Otal b Station Vent itPR-215 30,000 q e f

a Control ha /* Intake llPR-220 200 cpm a

fuel Handling Bldg Exhaust HPR-221A 30,000 cse f

(urstre.un of filters) y fuel ll.t:nt' h.9 Bldg Exhaust HPR-221B 1/,000 rpn (downst r ea n of fil ters)

Reai. tor Bldg 11 Purge Duct HPR-224 400,000 cie Reactor Bidg Purge Duct A HPR-225 50,000 cpu Reactor Bldg Purge Duct B HPR-226 200,000 cpn Auxilla y Bldg Exhaust Duct A liPR-222 300 rpn Auxiliary Bldg Exhaus Doct B HPR-223 40,000 cre l

Peactor Blda tir Sample Line itPR-22/

10cfn l

1/00 Ot>servation Tower I

0.5 f.,R/hr o r t -s,74' d

s N

N i

N N

i

, g b

ON-SITE DATA

,l

'b 6

Date: 3/30/79 Reading (n R/hr.)

j Tine M Q tocation i ns t rimm.n t

, Ce t a -Carra Cansna Pem.srks i

1203 Cooling Tower Unit 1 NRC Onsite 9

3

'e 1204 North Gate hRC Onsite 2

0.5 1210 North Gate NRC Onsite 2

1

(

1345 Unit 1 Warehouse NRC Onsite 13 4.5 8

i I.

l$18

'1..th Corner of Unit 2 hRC Onsite 40 9

een llouse 1540

.it 2 Screen llouse tiRC Onsite 50 10 1650 Unit 1 Screen llouse NRC Onsite 20 5

1659 IJa rehouse NRC Onsite 60 10 1745 Gate 10 by air Intake NRC Onsite 30 5

1828 Unit 1 Warehouse NRC Onsite 5

1928 Unit 1 Warehouse / Screen flouse NRC Onsite 10 s

1828 Unit 1 Screen liouse NRC Om i te 15 1

1828 Between Screen llouses NRC Onsite 50 I

&g 1828 Unit 2 Screen llouse tiRC Onsite 90 1828 Unit 1 MDCI NRC Onsite 20 I

e i