Reg Guide 1.39,Revision 2, Housekeeping Requirements for Water Cooled Nuclear Power Plants
ML19221A867
Person / Time
Issue date: 09/30/1977
From:
NRC OFFICE OF STANDARDS DEVELOPMENT
To:
References
REGGD-01.039, REGGD-1.039, NUDOCS 7907100163
Download: ML19221A867 (2)


Text

Revlalon 2

/g are,,\\

U.S. NUCLEAR REGULATORY COMMISSION September 1977 ge.

W@4 REGC_ATORY G EE

\\ ***,*

OFFICE OF STANDARDS DEVELOPMENT REGULATORY GUIDE 1.39 HOUSEKEEPING REQUIREMENTS FOR WATER-COOLED NUCLEAR POWER PLANTS A. INTRODUCTION proved and designated N45.2.3-1973 by the American National Standards Institute on March 15, Appendix B, " Quality Assurance Criteria for 1973.

Nuclear Pow er Plants and Fuel Reprocessing The original issuance of this regulatory guide en-Plants,' to 10 CFR Part 50, " Licensing of Produc-dorsed as acceptable the guidelines (indicated by the tion and Utilization Facilities," establishes oserall verb "should") as well as the requirements included quality assurance requirements for the design, con-in this standard. Some uncertainty arose with regard struction, and operation of safety-related structures, to the NRC staffs intent with this endorsement. As a systems, and components of nuc! car power plants.

result of this uncertainty, the NRC staff reevaluated This guide describes an acceptable method of com-the guidelines contained in ANSI N45.2.3-1973 with plying with the Commission's regulations with regard respect to importance to safety. This guide has been to housekeeping requirements for the control of resised to clarify N RC's position on the requirements work actisities, conditions, and environments at and guidelines included in ANSI N45.2.3-1973.

water-cooled nuclear power plant sites. The Advisory Where conformance to this regulatory guide is in-Committee on Reactor Safeguards has been con-dicated in an application without further qualifica-sulted concerning this guide and has concurred in the tion, this me. ins conformance with the requirements regulatory position.

of ANSI N45.2.3-1973, as supplemented or modified by the regulatory position of this guide.

Working Group N45-2.3 of the American National Standards Institute (ANSI) Standards Committee The requirements for the control of w ork activities, N45, Reactor Plants and Their Maintenance, has conditions, and ensironments at w ater-cooled prepared a standard that defines the housekeeping re-nuclear power plant sites that are included in ANSI quirements for the control of work activities, condi-Standard N45.2.3-1973, "flousekeeping During the tions, and ensironments that could affect the quality Construction Phase of Nuclear Pow er Plants,"2 of a nuclear power plant during the construction proside a method acceptable to the NRC staff for phase. This standard was approsed by Subcommittee comphing with the pertinent quality assurance re-N45-2, Nuclear Quality Assurance Standards, of the quiren$ents of Appendix B to 10 CFR Part 50, subject ANSI Standards Committee N45 and the full com-to the following:

mittee and its Secretariat. It was subsequently ap-

1. Subdivision 1.5 of ANSI N45.2.3-1973 states e t mes indwate substantne shanges from preuous mue.

that other documents that are required to be included

' llausti cepmg encom pse3 all actiutres relsed to control of deanhnen of falt:es, Jeanhness of materul and eppment. fire Copies may be obtained from the American Society of 2

f resenten and f re protectmn madmg dnposal of combustibic Meshanhal E.ngmeers. L.'nited I.ngineermg Center. 345 I ast 47th rrateruh and debru, control of attess, and protection of materuh Street. New Yo rk. N Y.10G17.

USNRC REGULATORY GUIDES c

menn e ou i.,e 5,nt io ine seur c. of ise c-won u s Nucie.r Reg #

"'U N ""*""*"

U"*""'*"d"*"

[7"*"" ** *"S*

Rey,% cu. des,, e ei va oes e u,,i o e.e, eo,we pac m, enod.

,~.m,e,~

wc.. a _ m

..,,,, m,, e e c _,s,,

r-rpar s e s. t o a-hw, e i e, n%es uv d dv ts, m n ew.N,ong s,c, A, p,othms The puntes are issue 1 n the f <>drwg ter tw o*1 d'vmons-m wta w e t.) es.v c ams Reg %lst er, G u wies DOst u J f ed A' ( 'E je r, s ee ' 'i pe u,41e qu r

I b)WW8' N'dCIo8 0 f

s Di Ar e not gotwt ?

eg q Jat.or.g enr1 r omp!'dof t eth IPe

  1. 1 nAt
  • 4.r gd 8'

'O 9

Memarts eruf va mi d e e t tr a'*.

T hw.e se' o ;t me g... des

  • li t.e e, rept

~ s,

.., e m,

t.m,,..,,

.m.,,~. ~., m,7 e,,,. _,,,,

,,,,,,,,,,,,,,s.,,,,

I 4 pe' m't Of Ise e try the (OremiSOQn,

O g,,, o# ago,d qu,,g, we g m,, t,,,,pe ades) or f oe plac e Comments ed sop +ons ' w eu %emems a 'be'.e p des ar e e" me eged et all p,,g,gg,,

f f brTes. 4%f gu del Wil tse f evt M ds AOtW Opr id e '

4 Om %Af 4'e P f)'WfbeMs 4Gd rnent ')tiArteuf Ome! t d Ef r 'buf'On t rst f ar Smgle a. opeen el f y' ure goedet en Sper.i aC Wfiling 10 the U S Nw( ?ar Reg Aatr<v Commission.

f d r ef.et t ne*n

,r f F J1 iO

d e 4 De' % e IPsQ.ade A 4% r % WJ 3% e f e%ut? Of d w gg)ng fouh! I'ie ?taile A sutzt.$M,ve t.ommer ts se emed ' rom tt.e wr a e odd 1 o64:

s' aN r ew. eve W a A ng' on, OC ? )'M A t r e. No 5 Over tot. Dawace of Dot ament Control 1907100/d

  • as a part of this standard are either identified at the housekeeping actisities occurring during the opera-point of reference or identified in P_.ograph 5 of the tions phase that are comparable to those occurring standard. The speciGe acceptability of these listed during the construction pha;e.

documents has been or will be cosered separately in other regulatory guides or in Commission regul:'-

tions, w nere appropriate.

D. IMPLEMENTATION

2. Subdisision 3.2.3 of ANSI N45.2.3-1973 in-cludes general guideline 3 and requirements for fire The purpose of this section is to provide informa-protection and pres entio.: The requirements and tion to applicants regarding the NRC staffs plans for guidelines of Subdisision 3.2.3 are not coasidered a using this regulatory guide.

part of this regulatory guide, since this subject is ad-dressed separately in more detail in other NRC docu-This guide reflects current NRC staff practice.

m:nts. Thus, a commitment to follow this regulatory Therefore, except in those cases in w hich the appli-gride does not imply a commitment to follow the cant proposes an acceptable alternatise method for guidelmes and requirements of Subdisision 3.2.3.

complymg with specified portions of the Com n%-

sion's regulations, the method described herein is be-

3. Although ANSI N45.2.3-lC3 is entitled ing and will continut to be used in the evaluation of

Housekeeping Durmg the Const;uction Phase of submittais for operating license or construction per-N uclear Pow er Plants." the requirements included in mit applications until this guide is resised as a result the standard, subject to the provision of Regulatory of suggestions from the public or additional staff Position C 2. are considered to be applicable for resiew.

O cA y

,3g L

J

?$::

s,

=o0 a:3

n
s 8'

3 Z

O 5

3*

53$ e3 82 aa in !!

\\26 \\ 0

!!! pd igr

"* a u "I

i 5

8 z

1.39-2