August 11, 1978 CQL 1330
. - r --
~-..j *.
Mr. B. H. Grier, Director Orrice of Int:pactictus & Enforecreent
~
U. S. Nucicar Mn;ulatory Cerminnion Region I 631 Park Avs.nue- -.-
1
~
4.~ing of P.r.ssia, Penn5ylvania _1.9L96 fu
..e..
pear Sir: - - -
Three Mile' Inland Nuc. lear Station Units 1 & 2 (TMI-I & TMI-2)
Operating Licensen Non. DPR-50 & DPR-73
(~-
Docket Nos. 50-289 & 50-320 IE Bul.letin 78-07 This letter in In response to IB Bulletin 76-oT concerning the protection afforded by air-line re*:pirutoru und nupplied-air hoods.
The Three MiJe_Tcland Ecspiratory ProtecC'lo7: Progra= does include the use
. [
- .1.-: ~ - r of air-line ;:uppl f eri respirators which can be operated in cither the demand mode or the cunLinuouc--flev modo, c HovcVer, all rdr-line supplied respirators
~
.at,TMI are by prucedure. uped-in the ccntinuous-flow c: ode.
x 2
-...,a.
The air-Jine supplied c gulators vill be modified to prevenL operation in
- the demand mode.
Tt is anticipated that the modification vill te com-pleted ty Cept, ember 30,.1978.
SIncetely,
~
165 327 J
c_.-
e J. G. Herbein Vice Pr-sident-Generation
~"'
JGH:RJS:dkf SI~ ~
~~
y_.
_m-._
cc: Directer ~~
-N.
em..
-- Divi' Ten of Puc1'Ya'c'ilities and Material a Safety Inspecticn Urrice of Inspecticn and Enforcement v.-
5: - --
U. S. Nuclear Regulatory Ccr=ission 7 905 23 03D.5 ff Vashington, D. C.
20555 0s T.
t
.wwwee..qy-w-wg-m-w--w.
- .www*
-r N
-N pee
--me
.w..i
ICW 1
...s UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D. C.
20555 J
'. ~ - -
-W~
June 12.1978
. % %. _ _:-w, m e -
s ww:--r-IE Bulletin No. 78-07 Date:
June 12, 1978 Page 1 of 3
.._ 2
- .. -r PROTECTION AFFORDED.BY AIR-LINE RESPIRATORS AND SUPPLIE0-AIR HOODS
_. -. -.. +.
Description cf 'CircWtance's- -
~
~
When the NucTear ReTulatory Cormission (NRC) established its current regulations and guidance on acceptable programs for respiratory pro-i,, J.
tection (10 CFR Part 20, 20.103(c) and Regulatory Guide 8.15), it announced its intention to revise the guidance as better infomation could be obtained and made available.
The Los Alamos Scientifi:
Laboratory (LASL) has been developing pertinent infomation under NRC contract and has submitted a Progress Report on' protection factors for air-line supplied-air respirators LA-7098-PR, and an Informal Report on supplied-air-hoods, LA-NUREG-6612-MS.
,, g ; _
.c-.
.A.
. Air-1 ire. supplied-air re::pirators
._.2 The report on air-line respirators indicates that the protection provided (protection factor) by certain full facepiece and half-mask facepiece, demand-mode-operated, air-if ne. Supplied air respirators is significantly less than was previously estimated from the limited information that was available wFen the protection factors in the current NRC guidance were published (Mgulatory Guide 8.15, Table I).
Specifically, the current guidance lists protection factors of 10 for half-mask facepieces and 50 for full f;cepieces that are used with air-line equipment that is operated in the. demand _ mode.
The information in the LASL report i
indicates thatjuch' of the equipment-of this type, even though NIOSH-s..
HESA* tested ~ nd certified;. does not achieve a protection factor grea ter a
than 5.'Jihe report.recomends.that such equipment no longer be certified
~[y, by ~NIOSif or )pproved_by.,NRC for use.
~-
.,. m..
-_ Supplied-air, hoods B.
'The repod on supplied-air hoods emphasizes the importance of maintaining a minimum air' flow of 6 cubic feet per minute (approximately 1701pm).
and recomends a. protection factor of 1,000 at this air flow if calibrated
- National Institute for Occupational Safety and Health-Mining Enforcement
~
and Safety Administration, Ye'sponsible for respirator certification.
MESA is now designated MSHA, Mining Safety and Health Administration.
=%
p
'-~'t - : = 2--
- =. -
165
.,28 3
n.-
_~
79052303 [
@J
1
- ...s.
-r.-
~~
Date:
June 12, 1978 Page 2 of 3
}'
_x_n e.:_. -
. n..._ -,.. _ _ -- w. W - -
air-line pressure gauges or flow measuring equipment are used.
A protection factor of 2,000, as given in the current NRC guidance, is recomended.for supplied-air hoods only when air flows are maintained at the manufacturer..'s. recocmended maximum rate.
s.-;. :
The NRC wild..further evaluate the infonnation in these reports and other pertinent infor nation and will revise its guidance a_s appropriate, e.g.,
by reducinch.tt e.p.co_tection factors permitted, or by eliminating the l
sprovals for or specifying particular conditions for the use of such equipment.
-.- ;f.
IT IS REC MMENDED THAT THE FOLLOWING ACTIONS BE CONSIDERED BY ALL LICENSEES WHO HAVE RESPIRATORY PPOTECTION PP,0 GRAMS:
1.
A ' protection factor of no more than 5 should be utilized for half-mask,,a_nd ful.l facepieces that are used with approved air-line e
. e'quipment ope _, rated in the demand mode.
.,. 3 : _
m.
e..- 2'#7A drotecti3Ifactor'~o'f n~o more than 1 000 should be utilized for
~
approved supplied-air hoods when the air flow is maintained at 6 cubic feet per minute and calibrated air-line pressure gauges or flow measuring equipment is used.
3.
A protectiEn factor of 2,000 shou'd be utilized for approved supplied-air hoods only when the air flow is maintained at the manufacturers recommended maximum ratt, this rate is greater than 6 cfm. and calibrated air-line pressure gauges or flow measuring equipment is used.
s.
=
Actions To B6'Taken -By Ljcensec_s:
C
.t.e,.
~= -.r-For all'liower' FeWtoffagiT1'tds~ wi th an eperating license, all research
~
react'drs with an ' operating license, all fuel cycle fccilities with an W
operating license'and all material licensees receiving this Bulletin:
1.
If your ree.piratory protection program includes the use of line supplied-air respirators operated in the demand made (not respirators operated in continuous-flow or pressure-demand modes) or supplied-air hoods, describn the actions you plan to take to assure proper protection of personnel in consideration of the information provided by this Bulletin.
.. - ~
w.
.N*
.:-- A
_y
, ~ '.'[
___. # ml
---...c w.-
F. ~
g __ _...
1'
- - ~ ~
~
IE Bulletin No. 78-07 Date:
June 12, 1978 e;,y.
a -
Page 3 of 3
'~~3 '
- mm..: _-,
--_:-y_w.
-- - + -
~
2.
If your respiratory prciection program includes the use of air-line supplied-air respirators operated in the demand r cde (not respirators operated in continuous-flow or pressure-demand-modes), determine the manufacturer, model and number of half-mask and ful-1 facepiece equipment used in this mode.
- . w-r.
.L_.
3.
Report in writing within 60 days thu.nformation required in items-4. and;27 -if applicable.
Reports are to be si 'xnitted to i
the Director of the appropriate NRC Regional Office listed in -
-er i
Appendix D of 10 CFR Pa. t 20 and a copy forwarded to the Director, W%
Division of Fuel Facilities and Materials Safety Inspection, U.S.
NRC, Office of Inspection and Enforcement, Washington, D.C.
20555.
I t
I Approval.by GAO, B180225(R0072); clearance expires 7/31/80.
Approval i
was given under a blanket clearar.cc specifically for identified generic problems. _
..i.-
n p.
,,...m. :, !. s.
~ ;
p.
~ - -
..=.,..:..-
..t"
- - ~ a t-F p
..~ m ~ +
~a. -
- w-
- s.. 5_-~~---
A e
'%.. w d.-
. emm.
.:_ =. - -
--J. ~ ".
~
~
~
165 330 W
~$- - - -
_v
- J
=
m.-.
s O
,,,,,y
.s 6,,,., nw,,
--),
N,5.METttOPOb TAN EDISON COMPANY
/f~ '^'.[
-h';;_
__ j POST OFFICE box 542 RE A DING, PE NN3Y LVANI A 19603 TELEPilONE 215 92'} 3001 September 19, 1978 i,
... M '.7 t
Gqi, 1522 r_
-a.
r.
... t..
n.2, -
Mr. D. H. Crier, Director,.w--
L --
Office of Inspect.f cn & thforcement -
~
Region I
-s a s._ E-U. S. Nuclear Regulatory Co=ntienton e.
6.11 Park Avenuo
^-'-
19fO6 Kins of Prussie., Pennsylvania i
Desr Sir:
'ihree $11e Taland Nuclear Station, Units 1 & 2 (T:C-1 5 TMI-2)
, Operpting T.icence Nos. DPR-50 and DPR-73 1,, ~ '
Dvket Nos. 50-289 nnd 50-320
i [,
IE Bull,etin 78,07, Additional Information
...w-r e -.
Met-Ed's leti,er_ of August 11, 1973.(GQL 1330), in response to IE Bulletin 78-07, stated tnat the air-lino supplied regulators vould be modified to
. prevent operation in the deraand mode, and that the modification would be ecrspleted by September 30, 1978. Hovever, the equipment vendor advised Met-Ed that installatio,n of the proposed modification would null and void the manufacturer'c'varranty.
Met-Li carrently uses SCO'IT P/N 802230 full facepiece assemblics, which as nta,ed in our responco, can be oper?.ted in either the demand mode or the continuouu-flow mode.
Therefore, in addition _ to the procedural centrol for
[
the use of the air-line supplied respirators, by September 30, 1976, CAUTION
~'
labels vill be affixed to'each :di-line.upplied regulator tc assure opera-
~
tion in the continuoun~ flev m6 der"-Purthermore, as the air-line suppli-d respJrutors require repl:tce ent;1. hey v311 be repleced with full facepiece, prossuro--demand = ode assemblien,
r Gincerely, d
nes
/
7 J. G. Herbein
- Vice President-Generat$on
' ~.. _.