ML19220C652
Jump to navigation
Jump to search
| ML19220C652 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 04/04/1979 |
| From: | Kelber C NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES) |
| To: | Murley T NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES) |
| References | |
| NUDOCS 7905110387 | |
| Download: ML19220C652 (1) | |
Text
i -ip & D -s y.
f 1
April 4,1979 NOTE T0:
Tom Murley FROM:
Charles Kelber
SUBJECT:
HYOROGEN SOLUBILITY Tom Walker and I have derived an engineering fit to the old H2 solubility data of Pray, Schweickert, and Minnich (Industrial and Engineering Cnemis try, 44, p.1116).
S(scc /cch 0) = P f(T) = solubility 2
where P = pressure, psia T = Tempe ra t ure,
F f(T) =.0082
.4710 T +.77710-7f This appears to be on the low side; an upper limit is about a
<(!
factor of two greater.
-w 4
CP;arles N. Kelber, Assistant Director for Advanced Reactor Safety Research cc:
L. Rib ARSR BCs T. J. Walker
(
'soazi osp
(
9 98 236
_