ML19220C601

From kanterella
Jump to navigation Jump to search
Summary of Natl Lab Support Work for Tmi.Info Partially Withheld:Home Telephone Numbers (Ref FOIA Exemption 6)
ML19220C601
Person / Time
Site: Crane 
Issue date: 04/07/1979
From: Bixby W, Ybarrondo L
EG&G, INC.
To: Ross D
Office of Nuclear Reactor Regulation
Shared Package
ML19220C598 List:
References
NUDOCS 7905110287
Download: ML19220C601 (13)


Text

MM SU?!!!ARY OF AT I ON A L LA 0RATORY SUPPORT 'iO R K FO R T!!R E E '1ILE ISLAND TO:

D.

Ross s'J FROM:

P,. N. S ii'fy / L. J. Ybarrondaf 7 /

/-

L t DATE:

Revision one, April 7,

1979 s

After our meeting with you and Roger ?tattson, on April 7,

Willits'and I updated the National Laboratory Support Work for Three Mile Island summary, incorporating all of your comments.

In particular, we called Berlinger of NRC and Tony Suhl, and have the new core celt calculations that your requested under way.

LY/ tab cc:

Tom Murley, NRC e

97 261 79051109#61

~

i

M s

g s

l

/

/

L C

v t

S i I!l l

s l

V

/

i "4

't b

/

/

L P

A K

/

/

/

/

L E

N I

L R

S i

/

L L

L L

/

S A

L

/

L N

A I

/

N R

O A

/

V V

I D

N A

S

/

L N

B n

i r s

rs e

n e

oe yd t

o s

n s

tl t n c

e ip i u u

i a

o t

e i

l v

nn l

d e

a l

t a

i oa i 4 o

r l

e G a v

y s

ns b

r o

u rt l

e r

o an p

C c

n eu t

l l r y

vo

/

l ee gc s

p ae t

i i n

e e

a d m ar i

x t t i

vt o

K g

z c

i n ki t

m e

na l

ra i

R a

i l i cc n

e eu i

ui sy O

m s

s n

ca o

e h

n m

b sd sr W

a a

w ut l l m

c e

nd u

a i o D

g e

o nn B a u

g on l

.r ft N

Ny F

o l

d oo r

r o

o ra r

r n

O l

d b

t i c wu t

i r

i s

th e ee e

o l

d ot s

d d

vs s gt rv E

u 1

'u e

ao l a n

a y

na 2

nia on P

F 1

B M

Rt F n I

R i

E g 1

I h w Ci l

1 Y

T 0

1 2

3

~

NATIONAL LA3 WORX S UM*t' R Y

. L A 3 0.' '.T O R Y Argonne DATE 6 April 1979 PACE

/

OF

//

':'C CO:iTACT:

':o : k Hone 30E CONTACT:

tio r k Hose 20NTkACTOR CONTACTS. John Honekamp (Cen t ra l Contact for all work)

Vork 312-972-2000 ext.

tio r k Wari Nork Home 312 s52-1453 4483 Ho e Ho=e Home

s IU)DI A R Y O F WORK PERFOUfED:

Thus far they are responding to only a few specific questions.

They had Bob Sevy here for a couple days, Roy McConnell a long ters B-N employee (ex) is working on helping estinate core damage.

He was at L'ync hb u r g 5 April.

TATUS:

They are just standing by!

iCOM:iEN D A T ION S :

Let them stand by until specific additional work ir required.

e sq 1

e e-.

l 97 20J

NATIONAL LAB NORK S U 5t hi A R Y 6 AP#i1 LABORATORY 3atte11e r tuabus DATE PAGE j?

0F

//

';2C CONTACT: Tony Suhl Nork 301-492-3523 Hone DOE CONTACT:

Work

.Home CONTRACTOR CONTACTS. Rich. Den.ning No r k 614 - 4 2 4 - 7 510 lio rk Nork

..o rk H o m e 61/,- 4 51 - 0 3 5 5 Home Home Home 1, SUM'lARYOF iiO R K PERFORMED:

1.

Doing meltdown calculations using the " March" thermal-hydraulics code and " Corral" to determine radionuclide release in containment 2.

Also working on a hydraulic simulation to estinate flow blockage and natural ci culation (being done by private Co.:

T.E.

Corp.,

Ted Mott 615-J66-5856)

STATUS:

1.

Done 2.

Not sure R ECO.' MEND AT IONS :

1.

Update by 4/11 for 4/11 and 4/13 conditions 2.

Coordinate thru Berlinger in Bethesda e

s 97 264

NATIONAL LAB WORK

SUMMARY

LA:0RATORY 3atte11e Pacific Northkest.

DATE 6 April PAGE 3

0F

//

IP.C CC" TACT:

Stan Fabic 20 ? k 301-427-4275 Hone 301-3 69-54 99 DOE CONTACT:

Work Hoce CONTRACTOR CONTACTS: Don Trent No rk 509-94 6-2105 Work Work Work Home Home Home Home

SUMMARY

OF WORK PERFORMED:

1.

Diagnostic work on the possible core c on figuration is just starting using COBRA 2.

Usiag Cobra to determine if it was really a bubble of steam vapor trapped in pockets in the core that gave such a large I

estimate of H2 bubble si:e.

I

! " ~e STATUS:

1.

Calculations j,ust getting started 2.

Ditto IECOMMENDATIONS:

1.

Coordinate thru Berlinger.

2.

Coordinate thru Berlinger and put on hold i

i e

4 3

0 6

0 e

9 7 n / 7, cos

NATIONAL LAB h0RK

SUMMARY

LA30RATORY 3ettis Atomic Power Lab CATE 4/6/79 Knolls Atomic Power Lab PAGE 4

0F

//.

NRC CONTACT: T.E.

Muricy

'lo t k 301-427-4281 Houe 301-469-7573 00E CONTACT:

Murray Miles; Bob Brodsky; Ted Schoenburg Work 202-577-2611 or 202-577-5531 (Murray)

Home 30L-654-2669 (Murray)

CONTRACTOR CONTACTS:

Bettis: Ralph Fredrickson KAPL: Dar Kronehock ext. 7393 Work 412-462-5000 Nork 518-393-6611 Nerk Work Hone Home 513 -3 74 -8 5 7 6 803e HU

SUMMARY

OF WORK PERFORMED:

1.

Radiolysis 2.

Environmental monitoring 3.

Coolant sample evaluations f

3TATUS:

1.

No more work ongoing-scientific advice on radiolysis..some calculations.

2.

Environacntal monitoring teams here; others on standby 3.

Awaiting coolant sample 4.

12 people on radiological work and decon

.ECOMMEND AT IONS :

1.

' Strengths:

Radiolysis; environmental monitoring; fission product transport; practical radiological work 2.

Murry Miles feels that the emergency situation ir over, people are not geareil up for 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> work.

Feel the capability they have can be duplicated 3 other labs.

3.

Bettis on hold pending further questions e

t i

i 97 266 e

NATIONAL LAB h0RK

SUMMARY

f. A E 0 ?. A T O R Y 3rookhaven ls'a t i o n a l Laboratory 6/79 DATE,

PAGE 3-0F

//

JRC C0 i TACT:

T.E.

Murley

'lo ? k 301-427-4251

!!o n e 301-469-7573 DOE CONTACT:

None Nork Hoce CONTRACTOR CONTACTS:

W.

Kato Telecopy 516-345-3000 Work 516-345-2444 Wo r k' Work Nork Home 516-473-3295 Hone Home Home

SUMMARY

OF WORK PERFORMED:

1.

Oconee Plant on RELAP/"SS asked to run the RELAP and IRT (trying to simulate accident) 2.

Trying to estimate solubilities /H2 radiolysis work 3.

Radictron monitoring / radiological assessments.

I S[ATUS:

i 1.

Ongoing 2.

On standby 3.

Uncertain RECOMMENDATIONS:

1.

Coordinate with Berlinger 2.

Stop 3.

Coordinate with lead agency at sit e [J'/ff) 9

+

,3 g]

20 P

e

NATIONAL LAB h0RK

SUMMARY

' A 3 0 ?. A T O R Y Lawerence Liverimere L a '. o r a t o r y DATE 4/6/79 P.', G E b

0F

//

NRC CONTACT:

T.E.

Murley

.o?k 301-427-4231 "One 301-464-7573 DOE CONTACT:

None Nork Hoce CONTRACTOR CCNTACTS:

Fred Jessen Wo rk 415-4 2 2-4 7 3 4 Work Nork Nork Mcme 415-528-7475 Home Home lio m e 41.5-422-7222

SUMMARY

OF WORK PERFORMED:

1.

Supplied atmosphere release predictions / identifying where containment were and are going /24 hr./ day / periodic reports on 2 hr. cycle 2.

Hot stop vans /2 mobile truck and trailer units /" sed for running people through 3.

Health safety 4.

Remote control robot - NORM 5.

Radiological equipment 6.

!!at er samples for analysis STATUS:

1.

Still operatiqnal 2.

On Standby 3.

On Standby 6.

Completed 4.

On Standby 5.

On Standby

.1 E C O MM EN D AT I ON S :

1.

Maintain. status quo - determine source of inquiry and ascertain whether question was answered 2.

Other capabilities Health safety Criticality calculations j

' Heat transfer j

Portable radiography equipment 1

P

. ~ - - _ _ _.. _. _ _ _.

NATIONAL LAB NORK

SUMMARY

LA50RATORY los Alanos Scientific L.ab DATE 4/6/79 PACE 7

cF

//

NRC CONTACT:

S.

Fabic ilo t k 361-427-4275

!{o-e 301-369-6499 DOE CONTACT:

None Nork lione CONTRACTOR CONTACTS: a.

Rich Pryor b.

J. Jackson

( a ) 'f o r k 505-672-2020 (b) fo rk 505-672-2125 Work Work Home 505-672-9019 Home 505-672-1547 li o = e Ilo n e SUM >lARY OF WORK PERFORMED:

1.

Gas bubble analysis; tried to model the B 5 N plant to determine how long it would take to depressuri:e system from 1000 psia to 300 psia; sensitivit'y to nodali:ation (50 mesh cell.

800 ft3 bubble.

2.

Develop finer mesh calculation for 2-3 minute transient.

I

' STATUS:

1.

Answer provided/1400 sec/ core temps nornal/ runs in r e a l' 't i m e 2.

Naiting in standby

!RECCMMENDATIONS:

1.

Coordinate with Berlinger i

i e

i 97.269 1

NATIONAL LA3 WORK

SUMMARY

LA20RATORY' Idaho National Engineering DATE 6 April 1979 PAGE

/3 OF

//

':RC CONTACT:

T.E.

Stu r l e y flo r k 301-427-4231 l!cne 203-522-5059 00E CO N T. A C T :

R.E.

Tiller Work 208-526 1439 Home 203.523-2769 CONTRACTOR CONTACTS: Hank Zeile (all work requests are to be cleared thru Hank)

Work 203-526-9708 Wo rk Work Work Home 203-522-5059 Home Hone Home SU$ DIARY OF NORK P E R F O R.*tE D :

1.

4, degassing during depressuri:ation - tests being conducted 2.

Use of a RTD to determine liquid / gas level in pressurizer tests being conducted 3.

Semiscale tests to examine bubble behavior.

4.

Natural circulation calculations to benchaark B 5 W calculations.

j 5.

Fuc1 damage calculations I

'5TATUS:

1.

Underway 2.

Should be done.6 April 3.

Two completed, one under consideration 4.

Underway 5.

Complete

  • iECOMMENDATIONS:

1.

Standby after concluding OP evaluation tests deternine if there is-need for a calibration of proposed degassing procedure.

2.

Drop after test is done.

Pass results to Bert Ackerman and

~

NRC site.

3.

Long term' diagnostic only 4.

Coordinate with Berlinger 5.

Standby for long ters diagnostics l

I i

i 8

91 D

.ee

- - - - = * ' +

_N.A..T I O N A L LAB h0RK S tH"t \\ R Y_

LA; ORATORY Oak Ridg2 National Lab.

DATE 4/6/79 PAGE f

0F

//

NRC CONTACT' T.E.

Muricy/ Tony Buhl for item (4) lo t *t 301-427-4231

!!cce 301-469-7573 00E CONTACT:

B. Adams Wo rk 615-516-0 7 2 3 Home CONTRACTOR CONTACTS:

(a)

J. Anderson (b) Les Oakes (c) Mario Fontana, (a)

(a) Work 615-574-5536 (b) Nork 615-514-5527 Nork 615-574-0557 Nork Hone Same Home 615-687-1809 Home Home

SUMMARY

OF NORK PERFORMED:

1.

Diagnostics of Noise Evaluation - evaluating response of TMI

/\\P's in plant and pressurizer 2.

Evaluating use of resistance thermocouple as an alternate means i

of pressurizer level in plant.

3.

Consultation on loose parts nonitoring/Gil Ziegler of SAI 4.

Work on possible core configuration using SABER code.

I

l. STATUS:

1.

Sy Sayth and J.

Robinson are at site.

j 2.

Awa iting re sul.t s o f t e s t s at INEL 3.

Ongoing 4.

Just starting i R E C O.':?!EN O AT I ON S :

1.

Continue.

2.

Continue 3.

Continue 4.

Coordinate with Tony Buhl 9

b e

NATIONAL LAB NORK

SUMMARY

LA30RATORY Sandia DATE 6 April 1979 PAGE /8 0F g/_

"RC CONTACT: Joe Murphy; Rod Satterfield on item (4)

Io ? k 301-492-8377

!!o m e DGE CONTACT:

Work Home CONTRACTOR CONTACTS:

Dave McClosky Nork 505-264-8870 Nork Nork Nork Home 50S-298-2923 Home Home Home

SUMMARY

OF WORK PERFORMED:

1.

They did ORIGEN calculations to predict core inventory - they are redoing them to correct a 10'5 error.

2.

Looked at calculating the possibility of H 2 explosions and or burning 3.

Did calculations on the solubility of H2 in water j

4.

Provided data on survivability of pressure transreceivers in high radiation fields and submergence in water.

l

' STATUS:

1.

Done except for correcting small error g

Done 3.

Done 4.

Done i

-RECOMMENDATIONS:

Document iteas 1 thru 4 to NRC 0 TMI site t

=

e e

f

NATIONAL LAS liO R K S U5tMA R Y

!.,* 2 0 AT O R Y Savannah River DATE 7 April 1979 PAGE

//

OF

//

NRC CONTACT:

Dick Vollmer for item 2 la r k Ilome DOE CONTACT:

Bob 5torgan Work 239-?405 Ho:e 303-648-7230 CONTRACTOR CONTACTS: Al H.

Peters Work S03-450-31S3 Wo r k Nork Work Mcme 303-513-8090 Home Home Home SU5!5fARY OF NORK PERFOR5tED:

1.

St el Pendergast of Savannah is on his way here to relieve U of California meteorology personnel at T5fI at request of U.C.

2.

Deliver charcoal to plant /9000 lbs. from Nuclear Consulting Services.

3.

Supporting ARAC 4.

Obtain components for backup RHR System /Need multiples of 2 (Westinghouse contact is Ffike Sieno)

S'TATUS:

5.

J. Lieberman/was asked for filters in, Aux. Building (Frank Palmer is GPU contact)

I

~

1.

N/A j

2.

Delivered 4/6 5.

Uncertain, GPU found filters 3.

On going thru WPPS 4

Possibly deliver 3000 gpm pumps

, R ECOSIN END AT IONS :

I 1.

Coordination of 2,4, and 5 is GPU 2.

Coordination of 1 and 3 by lead agency for radiological monitorir l

[TO BC SE2ECTEb]

i e

k IU e4 0

P

- * * * - - -