Q G r.

5,~

~

I t

April 2,1979 l

I'ENRNiDUM FOR:

Edward S. Christenbury, Chief licaring Counsel, OELD FRCM:

D. B. Vassallo, Assistant Director for Light Uater Reactors, Division of Project !'anagement

SUBJECT:

ADDITIONAL INFOPJ'ATION - BOARD IiOTIFICATIO!! BN-79.

REACTOR IllSPECTOR CONCERNS REGARDING B&W PLANTS Our recorr.endation (BN-79-10) for Board tiotification on this subject was provided in our rtecorandu:a of March.6,1979. At that time we advised that additional Board information would be provided follcwing receipt of the laE evaluations. The evaluations were provided to this office by the enclosed D. Thompson to D. B.. Vassallo memorandtaa of !! arch 29, 1979. We concur that they be provided to the.appropr.f ate Boards.

By separate memorandtn we will request a review by DSS which could lead to additional infonr.ation f7r the Boards. We recocuend, however, that the enclosed ISE evaluation be provided at this titr.e and not held up on the basis of any further review..

  • Origid!Fd b?

l D. B.1r.%

I D. B. Vassallo, Assistant Director l

for Light Water Reactors Division of Pro. ject "anagement i

I

Enclosure:

As stated cc:

H. Denton L. Nichols Distribut h E. Case B. Grines Central File D. Eisenhut J. Stolz

/ND caading J. Davis R. Saer F. Williams R. Boyd O. Parr F. Williams Reading R. Mattson S. Varga J. Lee V. Stello IE (7)

R. DeYoung D. Thocoson V. ttoare 4

l l

l l

10 @

TC:DPM AD: LWR:DPM FWilliams/b2 DBVassallo 9() 20e!

4/h/79 4/c/79 6/

[g> A Rf Gg%

UNITEO ! T ATES

*
f y't NUCLEAR REGULATCRY COMMISSION

, I.([y )

WASHINGTON D.C.20555 s "".abj l

%,.....f MAR 2 ') 99 w

MEMORA?IDUM FOR:

Domenic B. Vassallo, Assisant Director for Light Water Reactors, fiRR FRCM:

Dudley Thompson, XCOS

SUBJECT:

IllFORMATI0tt FOR BOARD ?40TIFICATIO:1 - DAVIS-BESSE U11TS 2 & 3 Af;D MIOLAtl0 U:1ITS i & 2 REFEREtlCES:

1.

!'emo : Thompson to Vassallo d Vi/79 2.

1'emo : Thompson to Vassallo e 3/12/79 2

As noted in the above referenced submittals additicnal information in the form of staff discussion and evaluation would be fcrthcoming on the capticned board notification.

Enclosed is the additional informa-tion for submittal to the appropriate Boards.

_ t j y,

. ?.' ~

Dudley Thompson, Exe,cutive Officer for C'perations Support Office of Inspection and Enforcement Cnclosures:

1.

Memo: Moseley to Thompson dtd 3/28/79 w/encls 2.

Memo: Moseley to Thompson dtd 3/29/79 cc:

l1. C. fioseley,'IE, w/o encl S. E. Bryan, IE, w/o enci J. F. Streeter, RIII, w/enci J. S. Creswell, RIII, w/enci G. C. Gower, IE, w/ encl IE Files w/enci

- - - - - - - m 1 DUPLICATE DOCUMENT gf} C0:4 TACT: G. C. Gower, IE 49-27246 Entire document previously entered I into system under: j ANO 796 N/ d h/[4 i No. of pages: / i

e g F

  • t cy,S o

.c UNI TE D Si s. ~r s

' *
p g*

f.UCLEAR R EGULAToltY CL*.?'USSION f,,! ~ ) W ASHING TCN, O. C. 205, 5 e March 29, 1979 ~ MEMORAliDUM FOR: Cudley Thompson, Executive Officer for Operations Support, IE FRCM: tiorman C. Moseley, Director, Division of Reactor Operations Inspection, IE

SUBJECT:

liOTIFICATI0ti 0F LICEllSING BOARDS In light of the transient experienced at Three Mile Island on March 28,19/9, we will review our preliminary evaluation of Item 3 contained in my March 28, 1979 memorandum to you. It is possible that the additional information will cause our assess-ment to change. ~ fsk A an & f .lorman C. Moseley Director Division of Reactor Operations Inspection, IE cc: S. E. B rya n E. L. Jordan R. F. Heishman, RIII J. C. Stone D. C. Kirkpatrick G. C. Gewer / p- -~#"~ V. D. Thcmas j DUPLICATE DOCUMENT l Entire document prev 1 ered [ into system under: n h ANO 74of// o b.2 O 1 No of pages: / h 3

e ,. [O " " 4,% t ,f. UNI T E 0 3T A Til; F* NUCLEAR REGULATOF Y CCM'.11SSION ., j %;d,i ? l. d. ;? ' {.$ / wa:mscTon. o. c. :sss

e. 't M g ' O 4 j' f,iAR 2 81979 MEMOPJfiDUM FOR:

Cudley Thompson, Executive Officer for Operations Support, IE FRCM: fiorman C. Moseley, Director, Division of Reactor Operations Inspection, IE

SUBJECT:

NOTIFICATIOri 0F LICENSING BOARDS On February 28, 1979, six items concerning Babcock and Wilcox designed nuclear plants were sent to you for forwarding to the appropriate licensing boards. At that time only a preliminary evaluation had been done. We have completed our evaluation of each.of the items and that information is enclosed. This additional infomation should be forwarded to the licensing boards. [s?, C;f

C y c.

fiorman C. Moseley Director Division of Reactor Operations Inspection, IE

Enclosure:

Evaluations of Concerns cc: S. E. B ryan E. L. Jordan R. F. Heishman, RIII J. C. Stone D. Kirkpatrick LG N Gewer V. D. Thomas ~ CONTACT: J. C. Stone -n (x28019) l DUPLICATE DOCUMENT 96 207 ,into system under: Entire document previously e l 6 ANO ] f 6 5lln 4L) No. of pages: / a}}