4 Distribution Central Files-NRR Reading
[&, c
.JAN 2 5 E73 RSB Reading 4#[
Rubin Chron MEMDRMCUM FOR: Robert J. Bosnak, Chief. Mechanical Enginee'.7g Br.
DSS FROM:
Thomas M. Novak, Cnief, Reactor Systects Branch, DSS SU3 JECT:
THREE MILE ISLAND UNIT 2, REQUEST FOR RELIEF FROM CERTAIN ASME CODE SECTION XI PUMPS AND VALVES IN-SERVICE TESTING REQUIREMENTS The Reactor Systems Branch has reviewed the Three Mile Island submittal requesting relief from ASME Section XI reouirements on certain corronents.
Several check valves in the safety injection system have not been classified properly. The following check valves should be reclassified to ASME category AC, with the reouired leak testing for this category of valve being perfonned to code specifications.
CFU4A, CFU48 Core Flood Discharge CFUSA, CFUSB RHR Discharge to Cold Leg DHV107A, DHV107B PJiR Discharge to Cold Leg MUV152A,B C,C or MUV402A,B.C.D Makeup Discharge o.-:m 3:: ed ny
.. - g Tnomas M. Novak, Chief Reactor Systems Branch Division of Systems Safety cc:
T. Novak S. Israel M. Rubin e
Contact:
M. Rubin, NRR x27591 7904300 % o e