Text
%
./-
,VZ o ? r, s.y i
/
'~
- r e i.....
/
fr u,,
n...
/
l METROPOLITAN EDISON CwMPANY vi.m or a:.cnu cucuc unuurs cc::m. ai -
ET OFFICL box 542 RE ADING. PE NNSYLVA?.! A 13CO3 TELEPHONE 215 - 921 2001 GQL 0522 l'r. Robert T. Carlson, Chief Facility Censtructicn and Engineering Support Branch Directcrate of Regulatery Operations - Region 1 631 Park Avenue King of Prussia, Pennsylvania 1ch06
Dear !&. Carlsen:
Doc:et No. 50-320 Ccnstruction Permit CPPR-66 Inspection No. 50-320/7h-06 This letter end the enclesure with this letter are in respense to your ispection report of October 25, 197h, ccncerning 16. Folsc='s September 2h-c6,197h, inspection of cur Three Mile Island nuclear Statica, Unit 2, and the findings thereof.
Sincerely, R. C. /puold l
Vice President RCA:JFV:tas
Enclosure:
Respcase to Description of Apparent Violations File: 20.1.1/7.7.3 2.2 cc:
R. L. Wayne, QA Manager, Design & Construction T. M. Cri== ins, Jr., Safety & Licensing 1'.anager R. W. Hevard, Jr., Project Manager W. A.'Verrochi, Vice President, Design & Construction Gerald Charnoff, Esquire 89 l90 3
- 7 90t30 ul66
)
E!iC1,0rWI I
M;tropolitan Edison Cenpeny Three I'lle Island nuclear Station, Unit 2 (TMI-2)
Docket no. 50-320 Constructicn Fer=it CFFR-66 Inspecticn No. 50-320/74-06 Recnence to Descrintion of Apnarent Violations Apne_ rent Violaticn "Criterica V of Appendix 3 cf 10CFR50 requires that activities affecting quality be acecrplished in accordance with docu=ented instructions, procedures,
or drawings.
Contrary to the above, it was observed that unused lov hydrogen velding electrodes were left in an cpen container exposed to the atmosphere for an extended pericd. This was in violation of site directive MCP-2-2 which requires that unused lov hydrogen filler =aterial in opened containers be returned to
~
the issuing crib within four hours."
Corrr'tive Actiens An investigation was begun upon discovery cf the above referenced situation, and the investigation disclosed that a.
the situation occurred 62. spite adequate procedural controls, b.
the velder who was responsible for the electrodes si= ply failed to report when they became missing, and c.
the use of these electrodes did 'not affect quality, in that the electrodes vere used only to mount a te=porary holding bracket, the function of which was to hold another co=ponent in position while the co=penent was being erected.
For this situation, i==ediate corrective acticns censisted -of destroying the subject electrodes, thus ensurin6 that they would a.
not be used in future applications, and b.
=aking a deter =ination, that there vere no previous applications.
of these electrodes which could have effected quality.
Preventative Actions
'Q
' G, 1
/
i
[
To avoid violations of this type in the future, the following preventative actions have been taken:
a.
B & W's velding supervisors have instructed, in detail, the crib attendants in velding electrode control procedure, b.
for those cases in which velders a_e working and electrodes nay be
=- -
zg4oa.=38-en/m
"nclosure
, Puce 2 drcpped cr.d beccre unretreviable by the velder hircelf, the labor forcec have been increased end inctructed to scrap all electrodes cc found, and c.
procedures hete been up-graded such that all velding electredes are ncv incued in a numbered container that must be retrcned and accounted for at the end of each shift by the crib attendant and velding cupervicer er his accistant.
Corpliance Adequr.te corrective and preventative actions have been cc pleted, and ccepliance has been achieved.
e I
pg
- C 'T J/
}/'
e
~
_I
.M