30"' 03575 Docket No. 50-320 H. Silver, Project Manager for Three Mile Island Unit 2, IWR Croup 2, RL THRU: Faust Roa,a, Section Laader, Electiieal. Instrumancation &

Control Syste=s 3 ranch. TR TOPICAL REFORT EVALUATION BAW 10003, REVISION 4, " QUALIFICATION TESTING OF PROTECTION SYSTEM INSTRUMENTATION" The staff has recently completed their review of the subject Topical Raport and identified several items that are required to be addressed by individual applicants that reference this Topical Raport.

(Ps.f ar:

Topical Reporr Evaluation, TAR 1044, transmitted by memorandum trcs V. Stello to V. A. Moore dated September 30, 1975).

Since this report has been referenced by the applicant for RPS equipment qualification we raquant that the applicant be raquested to address thess items (i.e., part 6 of the enclosed Topical Report Evaluation) and docu-mnt their results in the FSAR.

/s/

~

F. S. Asha Elactrical, Instru=antation and Control Systems Branch Division of Teewe=1 Raview Office of Nuclear Raactor Regulathn

Enclosure:

BAW-10003 Topical Esport gym 1 um clou cc:

V. Stallo T. Ippolito A. Schwencar F. Rosa DISTRI3UTION

[_D OCUT FILES NRR READING EIC READING F. ASHE U

o,.,e r.-

EIC:TR

_. EIC:T,R._

FAske:ng FRosa # "_d',

, w m. m..-

11/ 3 /75 11/,.7 / 75. _...

m.

Form AIC-318 ( Rev. 9 53) AIOf 0240

  1. u. s. eovsnmeern? rotsenne orricas te74.eae.s ee

(

-i

'T f~

} hQ \\

r -'

e-*W9.0 7 9 0 4 3 0 G C)Z /

'