ML19220B921

From kanterella
Jump to navigation Jump to search
Review of FSAR as Amended Through Amend 43 Is Complete.Amend Has Resolved Technical Deficiencies Noted in from RR Maccary to VA Moore
ML19220B921
Person / Time
Site: Crane Constellation icon.png
Issue date: 07/23/1975
From: Knight J
Office of Nuclear Reactor Regulation
To: Deyoung R
Office of Nuclear Reactor Regulation
References
NUDOCS 7904270661
Download: ML19220B921 (1)


Text

O R. C. DcYoung, Assistant Director for Light 'Jater Reactors Division of Project Manage =ent SA.FETY E7ALUAIION REPORT OF FSAR Plant Na::e: Three Mile Island Unit 2 Licensing Sta"*

OL Docket No.:

Responsible PM 3 ranch and Project "anager:

L'?.-4, E. Silver Respondin:; SS 3 ranch and Technical Reviewer:

MZ3, R. J. Kiessel Review Status: Co=plete The Mechanical Engineering 3rsach nas cc::pleted a review of sections 3.6, 3.9, 3.10, 4.2, 5.2 and 5.5 of the FSAR as amended throu~5 Am6ndment 43.

This n-endent has resolved the technical deficiencien noted in the R. R. Maccary letter to V. A. ho ire dated October 6,1975, which transmitted the MEB input to the SER.

OrisiL3131 E "

Ja. e s ?. EOi$**

J. P. Knight, Acting Assistant Director for Engineering Division of Systens Safety cc:

R. Eeine=an, SS S. Varga, FM D. Vassallo, ?M J. Knight, SS R. Bosnak, SS H. Silver, P'1 R. 3cyd, FM W. Mcdonald,-MIPC R. Kiessel, SS Docket File 50-320 7 904 27 0 6G (

NRR Reading File DSS:MEB File or,,e s,

DSS:MEB

_ a MEB O S:AAD/E

' ' ght _

8d. Oly RJKie ssel:jr _ R.T snak _

_7/M/76

,u.... s.

7@76_ _

_7M/76__.__

om, Forum AEC-518 (Rev. 9 5 5) AZO 4 0240 W w. s. novs==u ssrf Panamme orr'es i sta-one-i se