ANAC.

fHfl INTERNATIONAL July 31, 2019 U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-2738 Attn:

Document Control Desk Atlanta Corporate Headquarters 3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092 Phone 770-447-1144 www.nacintl.com

Subject:

Submission of Final Safety Analysis Report (FSAR), Revision 14 for the NAC-UMS FSAR (Docket No. 72-1015)

Reference:

1. ED20190002, Submission of Final Safety Analysis Report (FSAR),

Revision 13 for the NAC-UMS FSAR (Docket No. 72-1015),

March 11, 2019 In accordance with the requirements of 10 CPR 72.248, NAC International (NAC) herewith provides one copy of the changed pages necessary to complete the update of the NAC-UMS Universal Storage System Final Safety Analysis Report (FSAR) to Revision 14.

Revision 14 of the NAC-UMS FSAR is based on Reference 1 and on the changes that have been reviewed and incorporated by NAC under the 10 CPR 72.48 regulation and Certificate of Compliance Amendment 7. A certification of the accuracy of the Revision 14 changes by a duly authorized officer of NAC is provided as Attachment 1. A detailed description of the changes incorporated in Revision 14 of the NAC-UMS FSAR is provided in the List of Changes for the NAC-UMS FSAR, Revision 14, as Enclosure 1. Consistent with NAC administrative practice, Revision 14, changed pages are uniquely identified by the revision number located in the header of each page provided in Enclosure 2. Revision bars mark the FSAR text changes.

Since the revision to the NAC-UMS FSAR issued in March of 2019, there have been no 72.48 processed. Therefore a 10 CPR 72.48 Determination Summary Report for the NAC-UMS@

is not provided within.

If you have any questions regarding this letter, please feel free to contact me on my direct number at 678-328-1236.

Sincerely,,#'

Wren Fowler Director, Licensing Engineering : Certification of the Accuracy of the Revision 14 Changes :

List of Changes for the NAC-UMS FSAR, Revision 14 :

FSAR Changed Pages and LOEP for the NAC-UMS Universal Storage System, Revision 14 ED201900072

I NAC INTERNATIONAL Certification of the Accuracy of the Revision 14 Changes ED201900072 to ED20190072 Page 1 of2 Certification of Accuracy ofthe UMS FSAR, Revision 14 (Docket No 72-1015)

NAC International July 2019

NACINTERNATIONAL CERTIFICATION OF ACCURACY PURSUANT TO 10 CFR 72. 248(c)(4)(i)

George Carver (Affiant), Vice President, Engineering and Licensing, of NAC International, hereinafter referred to as NAC, at 3930 East Jones Bridge Road, Norcross, Georgia 30092, being duly sworn, deposes and certifies that:

1. Affiant has reviewed the information described in Item 2, is personally familiar with the preparation, checking and verification of that information and is authorized to certify its accuracy.
2. The information being certified as accurate includes all of the changes incorporated into the UMS Final Safety Analysis Report, Revision 14.

STATE OF GEORGIA, COUNTY OF GWINNETT Mr. George Carver, being duly sworn, deposes and says:

That he has read the foregoing affidavit and the matters stated therein are true and correct to the best of his know ledge, information and belief.

Executed at Norcros, Georgia, this.3/ ~ day of ~lWf",

2019.

Georg arver Vice President, Engineering and Licensing.

NAC International Subscribed and sworn before me this ~/ ~ day of _~~c.+4-~~---' 2019. to ED20190072 Page 2 of2

ANAC f<<fl INTERNATIONAL Atlanta Corporate Headquarters: 3930 East Jones Bridge Road, Norcross, Georgia 30092 USA Phone 770-447-1144, Fax 770-447-1797, www.nacintl.com

Enclosure I to ED20190072 Page I of2 List of Changes for the NAC-UMS FSAR Revision 14 (Docket No 72-1015)

NAC International July 2019 to ED2019072 Page 2 of2 List of Changes for the NAC-UMS FSAR, Revision 14 v,

  • "'\\ l'i i ':,

Chapter/Page/

. Source' of Change:

f

.Figure/Table l:r

>i -

Description d'f, Changf -

~oe,:

~~,

,J*'P1.,*

fi,*'(,,'""

t Note:

The List of Effective Pages and the Chapter Table of Contents, List of Figures and List of Tables have been revised accordingly to reflect the list of changes detailed below.

ChaQters 1 thru 11 - no changes ChaQter 12 Added last sentence to the first paragraph of Surveillance Page 12C3-31 Amendment 7, 18A Requirement SR 3.1.6.1.

ChaQter 13 - no changes

  • '>\\~
  • '-\\: <

to ED20190072 Page I of I List of Effective Pages and FSAR Changed Pages for the UMS FSAR, Revision 14 (Docket No 72-1015)

NAC International July 2019

July 2019 Revision 14 NAC-UMS Universal Storage System FINAL SAFETY ANALYSIS REPORT for the UMS Universal Storage System Docket No. 72-1015 ANAC ffifl INTERNATIONAL Atlanta Corporate Headquarters: 3930 East Jones Bridge Road, Norcross, Georgia 30092 USA Phone 770-447-1144, Fax 770-447-1797, www.nacintl.com

FSAR - UMS Universal Storage System Docket No. 72-1015 July2019 Revision 14 List of Effective Pages Chapter 1 1.5-12 thru 1.5-16..................... Revision 0 1-i.............................................. Revision 3 1.5-17........................................ Revision 3 1-ii.......................................... Revision 10 1.5-18 thru 1.5-20..................... Revision 0 1-1............................................ Revision 0 1.5-21........................................ Revision 6

............................................ Revision 5 1.5-22........................................ Revision 4 1-3 thru 1-9............................... Revision 8 1.5-23 thru 1.5-26..................... Revision 0 I. I-I.......................................... Revision 3 1.5-27........................................ Revision 3 l.1-2.......................................... Revision 4 1.5-28........................................ Revision 8 1.1-3.......................................... Revision 3 1.5-29........................................ Revision 0 1.1-4.......................................... Revision 0 1.5-30........................................ Revision 8 l.2-1 thru 1.2-2......................... Revision 3 1.5-31 thru 1.5-32..................... Revision 0 l.2-3.......................................... Revision 8 1.5-33........................................ Revision 3 1.2-4 thru 1.2-6......................... Revision 3 1.5-34........................................ Revision 5 1.2-7.......................................... Revision 8 1.5-35........................................ Revision 0 1.2-8 thru 1.2-9......................... Revision 3 1.5-36........................................ Revision 3 1.2-10........................................ Revision 8 1.5-37 thru 1.5-38................... Revision 10 1.2-11 thru 1.2-12..................... Revision 6 1.5-39 thru 1.5-43..................... Revision 0 1

13........................................ Revision 8 1.5-44........................................ Revision 8 1.2-14 thru 1.2-27..................... Revision 6 1.5-45 thru 1.5-46..................... Revision 0 1.2-28...................................... Revision 10 1.5-4 7........................................ Revision 3 1.2-29........................................ Revision 6 1.5-48........................................ Revision 8 1.......................................... Revision 4 1.5-49 thru 1.5-54..................... Revision 0 1.3-2.......................................... Revision 5 1.6-1.......................................... Revision 8 1.3-3.......................................... Revision 4 1.7-1.......................................... Revision 3 1.4-1 thru 1.4-2......................... Revision 0 1.7-2 thru 1.7-3......................... Revision 4 l.......................................... Revision 0 1.8-1........................................ Revision 12

........................................ Revision 11 1.8-2.......................................... Revision 7 1.5-3.......................................... Revision 0 1.5-4........................................ Revision 11 31 drawings (see Section 1.8) 1.5-5.......................................... Revision 8-1.5-6 thru 1.5-7......................... Revision 0 Chapter 2 1.5-8.......................................... Revision 6 2-i............................................. Revision 3 I.5-9........................................ Revision 13 2-ii......... :................................... Revision 6 1.5-10........................................ Revision 0 2-iii............................................ Revision 3 1 l........................................ Revision 3 2-iv.......................................... Revision 11

FSAR - UMS Universal Storage System Docket No. 72-1015 July 2019 Revision 14 List of Effective Pages (continued) 2-1............................................. Revision 8 3

1.......................................... Revision 0 2-2............................................. Revision 5 3.2-2 thru 3.2-4......................... Revision 3 2-3............................................. Revision 3 3.3-1 thru3.3-15....................... Revision3 2.1-1.......................................... Revision 5 3.3-16........................................ Revision 8 2.1.1-1 thru 2.1.1-4................... Revision 8 3.4.1-1.................................. Amendment 2 2.1.2-1 thru 2.1.2-3................... Revision 8 3.4.1-2....................................... Revision 4 2.1.3-1 thru 2.1.3-4................... Revision 8 3.4.1-3 thru 3.4.1-4.............. Amendment 2 2.1.3-5....................................... Revision 3 3.4.1-5....................................... Revision 3 2.1.3-6....................................... Revision 8 3.4.1-6 thru 3.4.1-8................... Revision 4 2.1.3-7 thru 2.1.3-8................... Revision 3 3.4.1-9..................................... Revision 11 2.1.3-9....................................... Revision 5 3.4.1-10 thru 3.4.1-12............... Revision 3 2.1.3-10 thru 2.1.3-14............... Revision 3 3.4.2-1....................................... Revision 8 2.2-1..................................... Amendment 1 3.4.2-2....................................... Revision 4 2.2-2 thru 2.2-3......................... Revision 0 3.4.3-1....................................... Revision 4 2.2-4.......................................... Revision 5 3.4.3-2 thru 3.4.3-3................... Revision 3

.......................................... Revision 3 3.4.3-4....................................... Revision 0 2.2-6 thru 10....................... Revision 0 3.4.3-5 thru 3.4.3-22................. Revision 3 2.2-11........................................ Revision 3 3.4.3-23 thru 3.4.3-26............... Revision 6 2.3-1 thru 2.3-2....................... Revision 11 3.4.3-27..................................... Revision 3 2.3-3 thru 2.3-4......................... Revision 3 3.4.3-28..................................... Revision 4 2.3-5 thru 2.3-6......................... Revision 6 3.4.3-29 thru 3.4.3-98............... Revision 3 2.3-7.......................................... Revision 0 3.4.4-1....................................... Revision 0 2.3-8 thru 2.3-9......................... Revision 3 3.4.4-2 thru 3.4.4-7................... Revision 3 2.3-10........................................ Revision 0 3.4.4-8 thru 3.4.4-9................. Revision 12 2.3-11........................................ Revision 5 3.4.4-10..................................... Revision 0 2.3-12 thru 2.3-19................... Revision 11 3.4.4-11 thru 3.4.4-18............... Revision 3 2.3-20........................................ Revision 3 3.4.4-19..................................... Revision 8 2.4-1.......................................... Revision 3 3.4.4-20..................................... Revision 3 2.4-2 thru 2.4-4......................... Revision 0 3.4.4-21 thru 3.4.4-38............... Revision 0 2.5-1 thru 2.5-2......................... Revision 3 3.4.4-39 thru 3.4.4-48............... Revision 3 3.4.4-49 thru 3.4.4-51............... Revision 0 Chapter 3 3.4.4-52 thru 3.4.4-64............... Revision 3 3-i............................................. Revision 3 3.4.4-65..................................... Revision 0 3-ii........................................... Revision 11 3.4.4-66 thru 3.4.4-69............... Revision 3 3-iii thru 3-viii........................... Revision 3 3.4.4-70 thru 3.4.4-74............... Revision 0 3.1-1 thru 3.1-7......................... Revision 3 3.4.4-75 thru 3.4.4-77............... Revision 3 2

FSAR - UMS Universal Storage System Docket No. 72-1015 July 2019 Revision 14 List of Effective Pages (continued) 3.4.5-1....................................... Revision 3 4.4.1-9....................................... Revision 5 3.5-1.......................................... Revision 4 4.4.1-10 thru 4.4.1-26............... Revision 3 3.6-1.......................................... Revision 8 4.4.1-27..................................... Revision 4 3.6-2.......................................... Revision 4 4.4.1-28..................................... Revision 5 3.6-3.......................................... Revision 8 4.4.1-29..................................... Revision 3 3.6-4 thru 3.6-5......................... Revision 3 4.4.1-30..................................... Revision 4 3.6-6..................................... Amendment 1 4.4.1-31 thru 4.4.1-34............... Revision 3 3.6-7 thru 3.6-8......................... Revision 3 4.4.1-35..................................... Revision 4 3.7-1 thru 3.7-2......................... Revision 3 4.4.1-36 thru 4.4.1-37............... Revision 3 3.7-3 thru 3.7-4......................... Revision 8 4.4.1-3 8..................................... Revision 7 3.8-1........................................ Revision 11 4.4.1-3 9 thru 4.4.1-40............... Revision 3 3.8-2 thru 3.8-20....................... Revision 9 4.4.1-41 thru 4.4.1-43............... Revision 4 3.8-21 thru 3.8-26................... Revision 11 4.4.1-44 thru 4.4.1-49............... Revision 3 4.4.2-1....................................... Revision 0 Chapter 4 4.4.3-1....................................... Revision 8 4-i thru 4-iv............................... Revision 3 4.4.3-2 thru 4.4.3-4................... Revision 4 4-v............................................ Revision 7 4.4.3-5 thru 4.4.3-13................. Revision 3 4-vi............................................ Revision 8 4.4.3-14 thru 4.4.3-15............... Revision 5 4.1-1.......................................... Revision 3 4.4.3-16..................................... Revision 3 4.1-2 thru 4.1-3......................... Revision 8 4.4.3-17..................................... Revision 4 4.1-4.......................................... Revision 0 4.4.3-18 thru 4.4.3-22............... Revision 3 4.1-5.......................................... Revision 4 4.4.4-1....................................... Revision 0 4.1-6.......................................... Revision 7 4.4.5-1....................................... Revision 8 4.1-7 thru 4.1-8......................... Revision 5 4.4.5-2 thru 4.4.5-3................... Revision 5 4.2-1 thru 4.2-3......................... Revision 3 4.4.5-4....................................... Revision 8 4.2-4.......................................... Revision 0 4.4.5-5....................................... Revision 3 4.2-5.......................................... Revision 4 4.4.6-1....................................... Revision 0 4.2-6.......................................... Revision 0 4.4. 7-1....................................... Revision 3 4.2-7.......................................... Revision 7 4.5-1.......................................... Revision 5 4.3-1 thru 4.3-3......................... Revision 3 4.5-2 thru 4.5-3......................... Revision 4 4.4-1.......................................... Revision 3 4.5-4..................................... Amendment 2 4.4.1-1....................................... Revision 3 4.5-5.......................................... Revision 3 4.4.1-2....................................... Revision 4 4.5-6.......................................... Revision 4 4.4.1-3....................................... Revision 7 4.5-7.......................................... Revision 3 4.4.1-4 thru 4.4.1-7................... Revision 0 4.5-8.......................................... Revision 8 4.4.1-8.................................. Amendment 2 4.5-9 thru 4.5-10....................... Revision 3 3

FSAR - UMS Universal Storage System Docket No. 72-1015 July 2019 Revision 14 List of Effective Pages (continued) 4.5-11 thru 4.5-16................ Amendment 2 5.6.1-4.................................. Amendment 1 4.5-17........................................ Revision 7 5.6.1-5....................................... Revision 4 4.5-18 thru 4.5-19..................... Revision 3 5.6.l-6thru 5.6.1-8................... Revision 3 4.6-1 thru 4.6-2......................... Revision 3 5.6.1-9 thru 5.6.1-10............ Amendment 1 4.6-3.......................................... Revision 0 5.6.1-11 thru 5.6.1-12............... Revision 8 4.6-4.......................................... Revision 8 5.6.1-13 thru 5.6.1-22.......... Amendment 2 5.6.1-23 thru 5.6.1-24............... Revision 3 Chapter 5 5.6.1-25................................ Amendment 2 5-i............................................. Revision 8 5.6.1-26 thru 5.6.1-27............... Revision 3 5-ii............................................. Revision 3 5.6.1-28 thru 5.6.1-34.......... Amendment 2 5-iii............................................ Revision 8 5.7-1 thru 5.7-2......................... Revision 0 5-iv thru 5-v.............................. Revision 3 5.7-3.......................................... Revision 8 5-vi thru 5-viii........................... Revision 8 5-ix........................................... Revision 3 Chapter 6 5.1-1........................................ Revision 12 6-i............................................ Revision 3 5.1-2 thru 5.1-12....................... Revision 7 6-ii............................................. Revision 8 5.2-1 thru 5.2-36....................... Revision 8 6-iii thru 6-vii............................ Revision 3 5.3-1 thru 5.3-10....................... Revision 3 6.1-1 thru 6.1-2......................... Revision 8 5.3-11 thru 5.3-12..................... Revision 4 6.1-3 thru 6.1-6......................... Revision 3 5.3-13 thru 5.3-21..................... Revision 3 6.2-1.......................................... Revision 5 5.3-22 thru 5.3-23..................... Revision 4 6.2-2 thru 6.2-3......................... Revision 3 5.3-24........................................ Revision 3 6.3-1 thru 6.3-2......................... Revision 3 5.3-25 thru 5.3-26..................... Revision 4 6.3-3........................................ Revision 10 5.3-27 thru 5.3-32..................... Revision 3 6.3-4 thru 6.3-6......................... Revision 3 5.4-1 thru 5.4-4......................... Revision 3 6.3-7.......................................... Revision 7 5.4-5.......................................... Revision 7 6.3-8.......................................... Revision 4 5.4-6 thru 5.4-27....................... Revision 3 6.3-9 thru 6.3-18....................... Revision 3 5.5-1.......................................... Revision 8 6.4-1.......................................... Revision 4 5.5-2.......................................... Revision 3 6.4-2 thru 6.4-16....................... Revision 3 5.5-3 thru 5.5-4......................... Revision 7 6.4-17........................................ Revision 0 5.5-5 thru 5.5-7......................... Revision 3 6.4-18 thru 6.4-40..................... Revision 3 5.5-8 thru 5.5-10....................... Revision 8 6.5-1 thru 6.5-49....................... Revision 3 5.6-1..................................... Amendment 1 6.6-1..................................... Amendment 2 5.6.1-1....................................... Revision 4 6.6.1-1 thru 6.6.1-2................... Revision 8 5.6.1-2.................................. Amendment 1 6.6.1-3.................................. Amendment 2 5.6.1-3....................................... Revision 4 6.6.1-4....................................... Revision 4 4

FSAR - UMS Universal Storage System Docket No. 72-1015 July2019 Revision 14 List of Effective Pages (continued) 6.6.1-5 thru 6.6.1-7................... Revision 8

8. I.1-3....................................... Revision 4 6.6.1-8....................................... Revision 3 8.1.1-4 thru 8.1.1-7................... Revision 8 6.6.1-9 thru 6.6.1-10............ Amendment 2 8.1.1-8 thru 8.1.1-10................. Revision 5 6.6.1-11..................................... Revision 8 8.1.1-11..................................... Revision 6 6.6.1-12 thru 6.6.1-14.......... Amendment 2 8.1.2-1 thru 8.1.2-2................... Revision 8 6.6.1-15..................................... Revision 4
8. 1.3-1 thru 8.1.3-2................... Revision 8 6.6.1-16 thru 6.6.1-21.......... Amendment2 8.2-i.......................................... Revision 6 6.6.1-22..................................... Revision 3 8.2-2.......................................... Revision 5 6.6.1-23 thru 6.6.1-24.......... Amendment 2 8.3-1.......................................... Revision 4 6.7-1.......................................... Revision 0 8.3-2 thru 8.3-4......................... Revision 3 6.7-2.......................................... Revision 5 8.4-1.......................................... Revision 0 6.8-1.......................................... Revision 7 6.8-2 thru 6.8-51....................... Revision 0 Chapter 9 6.8-52 thru 6.8-66..................... Revision 3 9-i............................................. Revision 7 9.l-l.......................................... Revision4 Chapter 7 9.1-2.......................................... Revision 8 7-i thru 7-ii................................ Revision 4 9.1-3.......................................... Revision 4 7.1-1 thru 7.1-2......................... Revision 8 9.1-4.......................................... Revision 5 7.1-3.......................................... Revision 4 9.1-5.......................................... Revision 4 7.1-4.......................................... Revision 8 9.1-6 thru 9.1-7....................... Revision 10 7.1

.......................................... Revision 4 9.1-8.......................................... Revision 7 7.1-6.......................................... Revision 8 9.1-9......................,................... Revision 4 7.1-7 thru 7. 1-9......................... Revision 4 9.1-10........................................ Revision 6 7.2-1.......................................... Revision 3 9.2-1.......................................... Revision 7 7.2-2.......................................... Revision 8 9.2-2.......................................... Revision 9 7.3-1.......................................... Revision 8 9.2-3.......................................... Revision 7 7.4-1.......................................... Revision 8 9.3-1.......................................... Revision 8 7.5-1.......................................... Revision 4 9.3-2.......................................... Revision 5 Chapter 8 Chapter 10 8-i....................................... Amendment l 10-i...................................... Amendment I 8-ii............................................ Revision 5 I 0-ii........................................... Revision 3 8-1 thru 8-2............................... Revision 5 I 0.1-1........................................ Revision 3 8.1-1.......................................... Revision 8 l 0.1-2........................................ Revision 6 8.1.1-1....................................... Revision 8 10.2-1 thru I 0.2-2..................... Revision 3 8.1.1-2....................................... Revision 5 10.3-1........................................ Revision 3 5

FSAR - UMS Universal Storage System Docket No. 72-1015 July 2019 Revision 14 List of Effective Pages (continued)

I 0.3-2 thru I 0.3-3..................... Revision 6 11.2.4-12................................. Revision 13 10.3-4........................................ Revision 0 11.2.4-13 thru 11.2.4-21........... Revision 0 10.3-5 thru 10.3-6..................... Revision 3 1.2.4-22 thru 11.2.4-24............. Revision 3 I 0.3-7........................................ Revision 0 11.2.4-25................................... Revision 7 10.3-8 thru 10.3-9..................... Revision 3 11.2.4-26 thru 11.2.4-27........... Revision 3 10.4-1 thru 10.4-5..................... Revision 3 11.2.5-1..................................... Revision 0 10.5-1................................... Amendment 1 11.2.6-1 thru 11.2.6-2............... Revision 3 10.6-1........................................ Revision 0 11.2.6-3................................... Revision 13 11.2.6-4..................................... Revision 0 Chapter 11 11.2.6-5..................................... Revision 3 11-i....................................... Amendment 1 11.2.7-1..................................... Revision 6 I I-ii........................................... Revision 3 11.2.7-2..................................... Revision 3 11-iii.......................................... Revision 5 11.2.8-1..................................... Revision 5 11-iv.......................................... Revision 8 11.2.8-2..................................... Revision 0 11-v........................................... Revision 3 11.2.8-3 thru 11.2.8-5............... Revision 3 I I-vi.......................................... Revision 8 11.2.8-6..................................... Revision 5 I I-vii thru 11-x......................... Revision 3 11.2.8-7..................................... Revision 3 11-1........................................... Revision 0 11.2.8-8 thru 11.2.8-10............. Revision 5 11.1.1-1..................................... Revision 6 11.2.8-11 thru 11.2.8-12......... Revision 13 11.1.1-2..................................... Revision 3 11.2.9-1..................................... Revision 0 11.1.1-3 thru 11.1.1-6............... Revision 0 11.2.9-2 thrul 1.2.9-4................ Revision 3 11.1.2-1..................................... Revision 6 11.2.9-5................................... Revision 13 11.1.2-2..................................... Revision 0 11.2.9-6 thru 11.2.9-7............... Revision 3 11.1.2-3..................................... Revision 3 11.2. l 0-1 thru 11.2.10-3........... Revision 0 11.1.3-1..................................... Revision 3 11.2.10-4................................. Revision 13 11.1.3-2 thru -11.1.3-3............ Revision 12 11.2.11-1................................... Revision 0 11.1.3-4 thru -11.1.3-16............ Revision 3 11.2.11-2thru11.2.11-4........... Revision 3 11.1.4-1 thru 1I.1.4-2............... Revision6 11.2.11-5 thru 1 1.2.11-7........... Revision 0 11.1.5-1 thru 11.1.5-2............... Revision 0 11.2.11-8 thru 11.2.11-11......... Revision 3 11.1.6-1................................ Amendment 1 11.2.11-12................................. Revision 0 11.2-1................................... Amendment 1 11.2.11-13............................... Revision 13 11.2.1-1 thru 11.2.1-7............... Revision 3 11.2.11-14................................. Revision 3 11.2.2-1..................................... Revision 8 11.2.12-1................................... Revision 0 11.2.3-1..................................... Revision 3 11.2.12-2................................... Revision 7 11.2.3-2..................................... Revision 0 11.2.12-3 thru 11.2.12-10......... Revision 3 11.2.4-1 thru 11.2.4-11............. Revision 3 11.2.12-11 thru 11.2.12-12....... Revision 0 6

(

FSAR - UMS Universal Storage System Docket No. 72-1015 July 2019 Revision 14 List of Effective Pages (continued) 11.2.12-13 thru 11.2.12-14....... Revision 3 11.2.12-15 thru 11.2.12-17..... Revision 12 11.2.12-18................................. Revision 0 11.2.12-19 thru 11.2.12-20....... Revision 3 11.2.12-21................................. Revision 0 11.2.12-22................................. Revision 3 11.2.12-23................................. Revision 0 11.2.12-24 thru 11.2.12-70....... Revision 3 11.2.12-71............................... Revision 13 11.2.13-1................................... Revision 6 11.2.13-2................................. Revision 13 11.2.13-3................................... Revision 0 11.2.14-1................................... Revision 8 11.2.14-2................................... Revision 3 11.2.15-1 thru 11.2.15-2........... Revision 3 11.2.15-3.............................. Amendment 1 11.2.15-4.............................. Amendment 2 11.2.15-5 thru 11.2.15-6........... Revision 8 11.2.15-7 thru 11.2.15-13.... Amendment 1 11.2.15-14 thru 11.2.15-17....... Revision 3 11.2.15-18 thru 11.2.15-22.. Amendment I 11.2.15-23 thru 11.2.15-24.. Amendment 2 11.2.15-25................................. Revision 4 11.2.15-26............................ Amendment 2 11.2.15-27............................ Amendment 1 11.2.15-28............................ Amendment 2 1 I.2.15-29................................. Revision 4 11.2.15-30 thru I 1.2.15-31....... Revision 3 11.2.15-32................................. Revision 4 11.2.15-33 thru 11.2.15-35.. Amendment 2 11.2. I 6-1 thru 11.2.16-10......... Revision 8 11.3-1........................................ Revision 3 11.3-2 thru 11.3-3..................... Revision 0 11.3-4........................................ Revision 3 11.3-5........................................ Revision 8 7

Chapter 12 12-i thru 12-ii....................... Amendment I 12-1........................................... Revision 5 12-2 thru 12-3........................... Revision 8 12-4........................................... Revision 3 l 2A-l thru I 2A-2...................... Revision 3 12B-l thrul2B-2....................... Revision 3 12C-l......................................... Revision 0 l 2C-2......................................... Revision 8 l 2C 1-1....................................... Revision 3 I 2C2-l....................................... Revision 8 l 2C2-2....................................... Revision 3 12C3-I thru I 2C3-8.................. Revision 0 12C3-9 thru I 2C3-28................ Revision 8 l 2C3-29 thru l 2C3-30............ Revision 13 l 2C3-3 l................................... Revision 14 12C3-32 thru I 2C3-34.............. Revision 8 l 2C3-35 thru I 2C3-37............ Revision 13 l 2C3-38 thru I 2C3-40.............. Revision 8 Chapter 13 13-i thru 13-ii............................ Revision 0 13.1-1 thru 13.2-7..................... Revision 0 13.2-8........................................ Revision 3 13.3-1...................................... Revision 10

Chapter 12-Operating

\\.

Controls and Limits

FSAR-UMS Universal Storage System Docket No. 72-1015 July 2019 Revision 14 SURVEILLANCE REQUIREMENTS REFERENCES SR 3.1.6.1 CONCRETE CASK Heat Removal System C3.l.6 The long-term integrity of the stored fuel is dependent on the ability of the CONCRETE CASK to reject heat from the CANISTER to the environment. Visual observation that all four air inlet and outlet screens are unobstructed and intact ensures that air flow past the CANISTER is occurring and heat transfer is taking place. However, partial blockage of less than two air inlet or outlet screens or the equivalent effective screen area does not result in the heat removal system being unable to provide adequate heat removal. Corrective actions should be taken promptly to remove the obstruction and restore full flow through the affected air inlet and outlet screens. Alternatively, based on the analyses, if the air temperature rise is less than the limits stated in the SR, adequate air flow and, therefore, adequate heat transfer is occurring to provide assurance of long-term fuel cladding integrity. The reference ambient temperature used to perform this Surveillance shall be measured at the ISFSJ facility. A minimum of two outlet air temperatures must be measured to provide an average outlet temperature to comply with Technical Specification SURVEILLANCE REQUIREMENT 3.1.6.1.

The Frequency of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is reasonable based on the time necessary for CONCRETE CASK and CANISTER components to heat up to unacceptable temperatures assuming design basis heat loads, and allowing for corrective actions to take place upon discovery of the blockage of the air inlet and outlet screens.

SR 3.1.6.2 The initial confirmation of the OPERABILITY of the CONCRETE CASK is established based on air temperature measurements at the CONCRETE CASK outlets and the ISFSI ambient, and verification that the air temperature rise is less than the limits stated in the SR. Following the initial confirmation, the continued OPERABILITY of the CONCRETE CASK shall be confirmed by one of the verification methods specified in SR 3.1.6.1.

The specified Frequency of once between 5 and 30 days after beginning STORAGE OPERATIONS is reasonable and ensures that the CONCRETE CASK has reached thermal equilibrium and, therefore, the outlet air temperature measurements will reflect expected temperatures under normal operations. Completion of the measurements within 30 days of placement of the CONCRETE CASK into STORAGE OPERA TJONS ensures that corrective actions can be taken to establish the OPERABLE status of the CONCRETE CASK within a reasonable period of time.

1.

FSAR Chapter 4 and Chapter 11, Section 11.1.2 and Section 1 l.2.13.

l 2C3-31

FSAR-UMS Universal Storage System Docket No. 72-1015 January 2009 Revision 8 CANISTER Surface Contamination C 3.2.1 C 3.2 C 3.2.1 NAC-UMS SYSTEM Radiation Protection CANISTER Surface Contamination BASES BACKGROUND APPLICABLE SAFETY ANALYSIS LCO A TRANSFER CASK containing an empty CANISTER is immersed in the spent fuel pool in order to load the spent fuel assemblies. The external surfaces of the CANISTER are maintained clean by the application of clean water to the annulus of the TRANSFER CASK.

However, there is potential for the surface of the CANISTER to become contaminated with the radioactive material in the spent fuel pool water. Contamination exceeding LCO limits is removed prior to moving the CONCRETE CASK containing the CANISTER to the ISFSI in order to minimize the radioactive contamination to personnel or the environment.

This allows the ISFSI to be entered without additional radiological controls to prevent the spread of contamination and reduces personnel dose due to the spread of loose contamination or airborne contamination. This is consistent with ALARA practices.

The radiation protection measures implemented at the ISFSI are based on the assumption that the exterior surfaces of the CANISTER are not significantly contaminated. Failure to decontaminate the surfaces of the CANISTER to below the LCO limits could lead to higher-than-projected occupational dose and potential site contamination.

Removable surface contamination on the exterior surfaces of the CANISTER is limited to 10,000 dpm/100 cm2 from beta and gamma sources and I 00 dpm/100 cm2 from alpha sources.

Only loose contamination is controlled, as fixed contamination will not result from the CANISTER loading process.

Experience has shown that these limits are low enough to prevent the spread of contamination to clean areas and are significantly less than the levels that could cause significant personnel skin dose.

( continued) 12C3-32

(

)