Research Info Ltr 24:transmits Results of Completed Research by Sandia Lab on Fesem Forcible Entry Effectiveness Model
ML19212A549
Person / Time
Issue date: 04/10/1978
From: Levine S
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
To: Casey Smith
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
RIL-024, RIL-24, NUDOCS 7912140521
Download: ML19212A549 (3)


Text

UNITED STATES

,8 NUCLEAR REGULATORY COMMIS$10N 12d2b g

7, E

WASHINGTDN, D. C. 20655

.\\....l../

APR 101978 6

e.

MEMORANDU!! FOR: Clifford V. Smith, Jr., Director

- Ac Office of Nuclear Material Safety pZ

.g and Safeguards h

g g

,q FROM:

Saul Levine, Director OE M h]

Office of Nuclear Regulatory Research o[

7 e

=

s

SUBJECT:

RESEARCH INFORMATION LETTER NO. 24 "FESEM" ADVERSARY a R

SEQUENCE EVALUATION MODEL EO

]

b Introduction This memorandum transmits the results* of completed research on the Forcible Entry Safeguards Effectiveness Model (FESEM), which is part of a continuing NRC research activity entitled " Effectiveness Evaluation Methods for Fixed-Site Physical Protection." The study was performed by Sandia Laboratories, Albuquerque, New Mexico, for the Office of Nuclear Regulatory Research (RES) in response to a research request (NMSS-77-1) from your office, identifying a need for evaluative methods for fixed-site theft and sabotage prevention systems.

The purpose of this study was to develop a methodology for analyzing fixed-site security systems as to their effectiveness against a forcible attack by an adversary intent on creating an act of sabotage or theft.

Analysis may include trade-offs involving on-site and off-site response forces and response times, perimeter system alarms, barrier configurations, and varying level.s of forcible attacks by an adversary. The model provides a framework for performing inexpensive experiments related to fixed-site security systems, for testing alternative decisions, and fcr determining the relative cost effectiveness associated with these decision policies.

Discussion FESEM is a Monte Carlo simulation model which can be applied to problems of forcible entry, for any assumed path, with an adversary having a variety of attributes, and gives an estimate of adversary success probability. The model includes essential elements of the fixed-site safeguards system which are related to the protective barriers for delay, sensors and alarms for detection, viewing and decision devices for

  • Chapman, L. D., G. A. Kinemond, and D. W. Sasser, " Users Guide for Evaluating Alternative Fixed-Site Physical Protection Using "FESEM","

Sandia Laboratories, Albuquerque New Mexico, SAND 77-1367, November 1977.

P 7912140 792190303

Clifford V. Smith, Jr. 7 qd.

assessment, consnunicatio1 methods, and engagement with the adversary.

6 Certain estimat$s of the functional capability of each of these elements are necessary inputs to FESEM.

In general, most of these data can be obtained directly from the facility to be analyzed. Once potential adversary targets and likely physical paths to these targets have been identified, fixed-site characteristics and barrier specifications can be generated for each physical path. Adversary attributes which affect the engagement model are randomly selected, based on attribute limits specified by the user.

Given the required input data, FESEM simulates an adversary action sequence using an analytical security force / adversary force engagement model.

One of four possible types of attack may be specified (or selected at random) for each simulation:

(1) external attack-sabotage; (2) external attack-theft; (3) internal assisted attack sabotage; and (4) internal assisted attack-theft.

Internal attack implies that a worker at the fixed site may be an ally of.the attackers and may, either by intent or under duress, degrade the alann and/or communication systems.

External attack implies that the attackers do not have internal assistance.

After the site characteristics have been selected, adversary attributes are generated, and an attack is simulated against the fixed site.

Internally aided attacks may serve to degrade the alarm and comunication systems.

Upon the arrival of a guard force meeting the minimum force requirements, a battle or engagement is initiated with the adversary.

During the engagement simulation, the adversary advancement is assumed to be interrupted.

If the adversary wins the battle, then his advancement continues until interrupted by the arrival of either on-site or off-site guard forces or completion of the theft or sabotage. This ends one simulation. Generally, between 500 - 1000 such simulated attacks are randomly generated against the site for each scenario. The model collects statistics on various aspects of each scenario that may be utilized by the decision maker as an aid in evaluating or upgrading a physical protection system.

Results The results of the FESEM analysis include estimates of the probability of sabotage or theft wins (and losses) based on attack force size, attack mobility, and type of attack; collected statistics associated with each variable (e.g., means, standard deviations, extreme values, etc.); and 15 optional histograms (e.g., number of wins by defenders and by attackers for successful sabotage or theft, alarm types for all runs, time required for successful sabotage or completion of theft, etc.).

I 1568 291

, G11fford V. Smith, Jr -

. The'FESEM is written in the GAdo IV s uulation language (FORTRAN-based) and processes both discrete and continuous events. The code uses the SCOPE system for the CDC-6600 r,omputer and is operational on the 9

mode on Sandia's NOS operating system.

BATCH mode on Sandia's SCOPE operating system and the time-sharing The computer memory requirement is approximately 100K octal and a single replication takes about 0.2 CPU second.

The program is currently available for NRC use via an access code number to Sandia's computer. A training program was given in February 1978 to interested NP.C personnel and potential users.

In the latter stages of Sandia's development and testing, numerous applications of FESEM were carried out. Assessments were made at 21 ERDA facilities, including Argonne, Battelle, Hanford, Livermore, Los Alamos, Oak Ridge, and Savannah River. Detailed studies were done at six ERDA facilities.

Recommendations It is recommended that the FESEM model be used by NMSS and other offices as an ancillary aid in formulating regulatory requirements, licensing, inspection and other monitoring operations. One output from FESEM provides the user with information that illustrates where the weaknesses are in the security system. Sensitivity analyses can be made to determine the worth of upgrading individual physical protection system components.

One can then determine appropriate upgrade actions and provide a cost / benefit analysis of the system improvements. There are numerous time-sharing terminals available throughout the NRC and technical questions regarding FESEM may be referred to R. C. Robinson of the Technical Support Branch.

Saul Levine, Director Office of Nuclear Regulatory Research 1568 292

i..

e C

7 0

CG O

h 1568 293

@5 P

....