ML19212A493

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 4949,Revision 2,for Radioactive Matl Shipping Package Model UNC-1484
ML19212A493
Person / Time
Site: 07104949
Issue date: 10/31/1979
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19210C063 List:
References
NUDOCS 7911130216
Download: ML19212A493 (2)


Text

n Form NRC418 U.S. NUCLE AR REGULATORY COMMISSION U

CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.

1.(c) Package Identification No.

1.(d) Pages No. 1.(e) Total No. Pages 49/2 2

USA /4949/AF 1

2

2. PRE AMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395. and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dar.gerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in itam 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71," Par. Sing of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certacn Conditions.'

2.(c)

This certificate does not relieve the consignor from compliance w.ch any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is imued on the basis of a safety analysis report of the package design or application-1(a) Preparer by (Name and address):

3.(b)

Title,nd identFication of report or application:

United Nuclear Corporation United Nuclear Corporation application dated Recovery Operations October 5, 1979.

I Wood River Junction, RI 02894 3

3.(c)

Docket No. 71-4949 4.

CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart O of 10 CFR 71, as applicable, and the conditions specified in item 5 below.

5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and

References:

(a) Packaging (1) Model No.: UNC-1484 (2) Description Containment vessel consists of a 51/4" ID x 361/2" long and 3/8" thick steel pipe with welded bottom plate and bolted top flange closure. Containment vessel is centered and supported within a 65 gallon minimum 16-gage steel drum with DOT Spec. 17H closure by plywood spacers, banelex, tubular steel spokes and insulation s

material.

(3) Drawings Container is constructed in accordance with United Nuclear Corporation Drawing No. D-5005-8017, Rev.1.

(b) Contents (1) Type and form of material Uranium oxide and compounds which will withstand a temperature of 750 without pressure generating decomposition.

Density may not exceed 5.3 g U/cc.

The theoretical-density-moderator relationship for "U compounds" shown in Figure 309 XXIV, dated j 3jg 33Q 7911130 $ [ 4

Page 2 - Certificate No. 4949 - Revision 2 - Docket No. 71-4949 5.

(b) Contents (1) Type and form of material (Continued)

February 6,1970, Docket 70-36, or in Figure 1.D.17 of the UK Handbook may not be exceeded.

Uranium may be enriched to any degree in the U-235 isotope. The maximum H/X atomic ratio considering all sources of hydrogenous material interspersed with the fissile material shall not exceed 0.5.

(2) Maximum quantity of material per package Total contents not to exceed 65 pounds with the U-235 content not to exceed 26.4 kg.

(c) Fissile Class II and III (1) Minimum transport index to 2.0 be shown on label for Class II (7.) Maximum number of packages per 50 shipment for Class III 6.

The package authorized by this certificate is hereby approved for use under the general license provision 5 of 10 CFR 571.12(b).

7.

Expiration date: December 31, 1984.

REFERENCE United Nuclear Corporation application dated October 5,1979.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date: OCT 91 1979

)3}9

-