Responds to IE Bulletin 79-25, Failures of Westinghouse Bfd Relays in Safety-Related Sys. No Westhinghouse Bfd/Nbfd Relays Utilized or Planned for Use at Util
ML19211D199
Person / Time
Site: Midland
Issue date: 12/18/1979
From: Howell S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
IEB-79-25, NUDOCS 8001170032
Download: ML19211D199 (1)


Text

.

TI C

/

p ( C" i.f i COIISum2fS

! Power Sa "*" " " * *

/

CD@W Senior Vice President General of fices: 1945 West Parnall Road, Jackson, Michigan 49201 * (517) 788 4453 December 16, 1979 liove 322-79 Mr J G Keppler, Regional Director iluelear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL (20137 MIDLEID PROJECT DOCK 1;T No 50-329, 50-330 IE BULLETIN 79-25 FILIl: 0505.12 UFI: 99*02'05*10 SERIAL: 8094 We have reviewed IE Bulletin 79-25 on the subject of " Failures of Westinghouse BFD Relays in Safety-Related Systems" and conducted an investigation to determine whether destinghouse type EFD/3BFD relays are being used or planned for use in the safety systems at the Midland Plant. Through our investigation, we have determined that there are no Westinghouse BFD/N3FD relays utilized or planned for use in safety-related systems at the Midland Plant.

~

u ,:.L Chs" A'A Sidi/ja CC: Director, Huclear Reactor Regulation Director, Office of Inspection & Enforcement 1761 300 DEC261979 S 001170 Q {