ML19211C788

From kanterella
Jump to navigation Jump to search
Forwards Supplemental Response to 790615 & 0831 Deficiency Repts Re Cable Terminations in Junction Boxes Inside Containment
ML19211C788
Person / Time
Site: Sequoyah  
Issue date: 12/18/1979
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19211C789 List:
References
NCR-EEB-79-7, NCR-EEB-79-9P, NUDOCS 8001140496
Download: ML19211C788 (1)


Text

TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 374ot 400 Chestnut Street Tower II December 18, 1979 1

~

av Mr. Ja=es P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Co==ission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 - CABLE TERMINATIONS IN JUNCTION BOXES INSIDE CONTAINMENT - NCR'S EEB 79-7 AND 9P - SUPPLEMENTAL RESPONSE The subject nonconformances were initially reported to NRC-01E Inspector W. T. Cottle on June 15,1979 (NCR EEE 79-7), and August 31, 1979 (NCR 9P).

Enclosed is supplemental information on these nonconformances.

An identical nonconformance is addressed for Watts Bar Nuclear Plant by NCR EES 79-8.

If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 854-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITY IN/s x

j,

\\.

& O.,

h L. M. Mills, Mhnager Nuclear Regulation and Safety Enclosure cc:

Mr. Victor Stello, Jr., Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission

}} Washington, DC 20555 D wi 8001140 t % An Equal Opportunity Employer 1}}