Text

.

8(pa nea og'o UNITED STATES g

NUCLEAR REGULATORY COMMISSION o

E WASWNGTON. D. C 20666

/

NORTHERN ST* 15 POWER COMPANY, DOCKET NO. 50-263 MONTICELLO NUCLEAR GENERATING PLANT, UNIT NO. 1 AMENDMENT TO PROVISIONAL OPERATING LICENSE Amendment No. 42 License No. DPR-22 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Northern States Power Company (the licensee) dated December 21, 1979, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment, and paragraph 3.8. of Provisional Operating License No. DPR-22 is hereby amended to read as follows:

B.

Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 42, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

1739 093 son" "

0%

. 3.

This license amendment is effective as of the date of it: issuance.

FOR THE NU L REGULATORY COMISSION

/

/n Thomas A. Ippolito, Chi f Operating Reactors Branch #3 Division of Operating Reactors

Attachment:

Changes to the Technical Specifications Date of Issuance:

December 28, 1979 1739 094

ATTACHMENT TO LICENSE AMENDMENT NO. 42 PROVISIONAL OPERATING LICENSE NO. DPR-22 DOCKET NO. 50-263 Replace the following page of the Appendix "A" Technical Specifications with the enclosed page.

The revised page is identified by Amendment number and contains vertical lines indicating the area of change.

Remove Insert 189E 189E 1739 095

TABLE 3.11.1 MAXIMUM AVERAGE PLANAR LINEAR IIEAT GENERATION RATE vs. EXPOSURE Exposure MAPLilGR FDR EACil FUEL TYPE (kw/f t)

MWD /STU 8DB262 8DB250 8DB219L 8DRB265 8DRB282 200 10.6 10.6 10.7 10.4 10.3 1,000 10.7 10.7 10.7 10.4 10.4 5,000 10.7 10.7 10.8 10.4 10.4 10,000 10.8 10.8 10.7 10.5 10.5 15,000 10.7 10.7 10.7 10.5 10.5 20,000 10.7 10.6 10.6 10.4 10.4 25,000 10.6 10.6 10.6 10.3 10.3 N

L/4 30,000 10.6 10.6 10.2 10.3 10.3 4

35,000 9.8

}(

40,000 8.9 189E 3.11/4.11 REV Amendment No. 42