ML19211C029

From kanterella
Jump to navigation Jump to search
Forwards General Comments on Oct Draft Task 10/TAP A-40, Phase I Rept, in Response to 791023 Request.Recommends Specific Changes in Content & Wording of Text,To Indicate Direct Application of Revision of SRP
ML19211C029
Person / Time
Issue date: 11/26/1979
From: Schauer F
Office of Nuclear Reactor Regulation
To: Bagchi G
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
References
REF-GTECI-A-40, REF-GTECI-SC, TASK-A-40, TASK-OR NUDOCS 8001090073
Download: ML19211C029 (3)


Text

.

jr

  • 60.

h UNITED STATES E'

'l 'g NUCLEAR REGULATORY COMMISSION

,.c,

g E

WASHINGTON, D. C. 20555 s

l'. i' l NOV 2 01979 MEf;0RANDUM FOR:

G. Bagchi, Chief Structural Engineering Branch,RSR,RES F. Schauer, Chief, Structural Engineering Branch, DSS FROM:

REVIEW 0F OCTOBER DRAFT OF TASK 10/ TAP A-40 REPORT

SUBJECT:

Letter from D.W. Coats, Jr., (LLL) to G. Bagchi (NRC)

Reference:

dated October 23, 1979, with enclosure Enclosed are general coments on the subject report prepared by S.Chan of the Structural Engineering Branch. Please review and consider the comments as appropriate.

2 6 >> &

n -

" anz P. Schauer, Chief Structural Engineering Branch Division of Systems Safety

Enclosure:

as Stated t- ::. T Hanauer J. Knight L. Shao J. Richardson D. Jeng C. Tan S. Chan f

1737 065 800109007.3

GENERAL COMMENT

S ON DRAFT TASK 10/ TAP A-40 PHASE I REPORT 1.

The form of this report cannot provide specific and direct application of recommended revisions of SRP. We suggest use of (1) mark-ups on the present SRP copy (such as the mark-up copy of SRP 3.7.1 and 3.7.2 previously made by SEB), or (2) itemizing specific changes of the present SRP (e.g. Paragraph I.2.a - Delete; Paragraph II.3.b - change

" sentence 1" to " sentence 2;" add Paragraph xxx....)

In other words, we like to see specific changes of contents and wordings on the present text, not just comments and loose recommendations. We like to know exactly how the SRP be revised on a marked-up copy and the background, bases and justifications o,f these revisions in separate reports.

2.

All technical terms that may be unfamiliar to many engineers should be defined and explained (e.g. consistent synthetic earthquakes p.15; broad band site specific spectrum, p 20; effective peak ground acceleration p. 22; deconvolution, p. 23; frequency content, energy content, p. 24; primary and secondary nonlinearities, p. 27. )

3.

Chapter II, III and IV are actually three individual reports somewhat related and overlapped. They can be served as good background material if technical justifications, theoretical bases and analytical proofs are provided to support their statements.

1737 066

, 4.

Several corm 1ments previously made by C. P. Tan and S. P. Chan, transmitted through the memoranda of 7-31-79 and 9-7-79 from F. P. Schauer to G. Bagchi, have not been considered.

1737 067

.