Text
.
km REO UNITED STATES 8
j%,
NUCLEAR REGULATORY COMMISslON WASHINGTON, D. C. 20555 3
j
./
SEP 171979 MEMORANDUM FOR:
R. E. Johnson Engineering Branch Division of Operating Reactors, NRR R. M. Gamble Materials Engineering Branch Division of Systems Safety, NRR FROM:
M. Vagins Metallurgy & Materials Research Branch Division of Reactor Safety Research, RES
SUBJECT:
CHARPY DATA 0N IRRADIATED LOW UPPER SHELF WELDMENTS Attached are the first data on the irradiated low upper shelf weldments developed as a consequence of the meeting held here on July 5 and 6,1979, and described to you by my memo dated July 12, 1979. These data deal with the results of the Charpy V-notch specimens from 61W, 62W and 63W weldments.
These data on the results of the.5TCT on J modified.5TCT specimen testing should be in your hands by the end of September.
If you have any questions regarding this information, please call me on 74262.
&)
m M lto agins Metal urgy & Materials Research Branch Division of Reactor Safety Research
Enclosure:
as stated cc w/ encl:
S. Hanauer, NRR 1739 287 W. S. Hazelton, NRR V. S. Noonan, NRR J. P. rsnight, NRR S.S. Pawlicki, NRR P. Albrecht, RES 8001070
.