U.S. NUCLE AR REGUL ATORY COMMISSION W r71 or rice or suspEcrioN Awo ENFORCEMENT INSPECTION FINDINGS AND LICENSEEfCKNOWLEDGMENT
- 9. LIC E NsE E
&CYeYr) De.C-fYiC Co,
- c.,. _..,, a...., C_,. 1.
777 N. But O'wllun
- z*c" 1" 799 Ecosevelt Ro.d lees Seteni h
...., u -.,..,
- a Eny E 6M37 3
a.oocnarnuu. anni 2 4 - 0 (o Of5 01
- { gg )
... c
- s. oava or insercrioa 1S,l/0
-oz
- 6. $NSPECvloM FINDINGS The inspection was an esamination of the activities conducted under your license as they relate to radiation safety and to compliance Commission's rules and regulations and the conditions of your license. The inspection consisted of selective esaminations of procedures a sentative records. interviews with personnel.and observations by the inspector. The findings as a result of this inspection are as follows:
No items of noncomphance or unsafe conditions were found.
The following items of noncompliance related to records, signs. and labels were found:
O A. Rooms or areas were not properly posted to indicate the presence of a RADIATION AREA.10CFR 20.203(b)or 34 O
B. Rooms or areas were not properly posted to indicate the presence of a lilGil RADI ATION AREA.
10 CFR 20.203(c)(1) or 34.42 O
C. Rooms or areas were not properly posted to insticate the presence of an AIRBORNE RADIOACTIVITY AREA.
10 CFR 20.203(d)
C D. Rooms or areas were not properly posted to indicate the presence of RADIOACTIVE M ATERIAL.10 CFR 20.203(
O E. Containers were not properly labeled to indicate the presence of RADIOACTIVE M ATERI AL.
10 CFR 20.203(f)(1) or (f)(2)
C F. A current copy of 10 CFR 20, a copy of the license, or a copy of the operating procedures was not properly posted made available.10 CFR 20.206(b)
O G. FormNRC-3 was not properly posted.10 CFR 20.206(c)
O 11. Records of the radiation exposure ofindividuals were not properly maintained.10 CFR 20.401(a) or 34.33(b)
O
- l. Records of surveys or disposals were not properly maintained.10 CFR 20.401(b) or 34.43(d)
O J. Records of receipt, transfer, disposal, export or inventory oflicensed material were not p Operly maintained.
10 CFR 30.51,40.61 or 70.51 O
K. Records ofleak tests were not maintained as prescribed in your license,or 10 CFR 34.2S(c)
O L Records ofinventories were not maintained.10 CFR 34.26 O
M. Utilization logs were not maintained.10 CFR 34.27 O
N. Records of radiation survey instrument calibration were not maintair.ed.10 CFR 34.24 O o. Records of teletherapy electrical interlock tests were not maintained as prescribed in your license, y
O P. Other
)
ll
- ~ ~
/f(ARC lurector)
/