ML19211A971

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 5467,Revision 4,for Boxes W/Lids, Pallets W/Covers & Pallets W/O Covers.Interdepartmental Correspondence Encl
ML19211A971
Person / Time
Site: 07105467
Issue date: 08/13/1979
From:
ENERGY, DEPT. OF
To:
Shared Package
ML19211A967 List:
References
14941, NUDOCS 7912210425
Download: ML19211A971 (13)


Text

_ _ _ _ _.

U.S. DEPARTMENT OF ENER3Y

$I'1777" CERTIFICATE OF COMPLIANCE 7

H C" '

For Radioactive Matenals Packages Ia. Certificato Numoer 1b. Revision No.

Ic. Package identification No.

Id. Page No.

Ie. Total No. Pages.

5467 4

USA /5467/AF (DOE-OR) 1 Il

2. PREAMBLE 2a.

This certificate is issued to satisfy Sections 173.393a,173J94,173.395, and 173.396 of the Deoartment of Transportation Hazardous Materials Regulations (49 CFR 170-189),

2b.

The packaging and contents coscribed in item 5 below, meets the safety standares set forth in Subpart C of Title 10, Code of Federal Regulations.Part 71," Packaging of Radioactive Matenal for Transport and Transportation of Radioactne Material Under Certain Conditions."

5 2c.

This certificats does not recieve tha consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the gowrnrnent of any country through or into which the pecuage will be transported.

3. This certificate is issued on the basis of a safety analysis report of tne package assign or appaication-til Prepared Dy (Narne and addressli (I) Title and identification of report or appucation:

(3) Date:

(a) National Lead Company of Ohio NLCO-1107 July 1974 Post Office Box 39158 DUN -7988 June 1972 Cincinnati, Ohio 45239 UNI -417 Aug. 25, 1976 (b) United Nuclear Industries, Inc..

UNI -483 - Rev. 1 June 23, 1976 Post Office Box 490 l

UNI -489 Jan. 16, 1976 (continued on na2e 2) m M,M mM,e nn 49M2 i

4. CONDITICNS This certificate is conditional upon the fulfilling of the requirements of Suboort O of 10 CF R 71, as applicab:e, and the conditions specified in item 5 below.
5. Description of Pacmaging and Autnorireo Contents. Model Numcer, Fissile Class, Otner Concitions, and

References:

a.

The titles of the refer ances SARP's listed in 3 above are as fM1:,vs:

NLCO-1107 - SAFETY ANALYSIS REPORT FOR PACKAGING STEEL BANDED WOODEN SHIPPING CONTAINERS FOR SLIGHTLY ENRICHED URANIUM METE.

D. L. Dunaway DUN -7988 CRITICALITY SAFETY OF URANIUM METE SCRAP IN MASONRY CONCRETE BILLETS.

H. Toffer & E. A. Weakley UNI -417 AMENDMENT TO NLCO-1107 MULTIPLE STACKING OF NLO STEEL BANDED WOODEN SHIPPING CONTAINERS.

K. L. Fowler UNI -483 SAFETY ANALYSIS REPORT - PACKAGING SUPPLEMENT TO NLCO-1107 FOR SHIP-Rev. 1 MENT OF URANIUM FUEL EITRUSIONS, BOLTED SECTIONS, AND SHIP?ING TUBES OF URANIUM FRAGMENTS IN NLO BOXES.

K. L. Fowler UNI -489 NUCLEAR CRITICEITY SAFETY ANALYSES AND TECHNICE BASES FOR SHIPPING REJECT URANIUM METAL IN NLO BOXES.

H. Toffer DPSP SUPPLEMENT TO " SAFETY ANALYSIS REPORT FOR PACKAGING, STEEL BANDED 71-6 WOODEN SHIPPING CONTAINERS FROM SLIGHTLY ENRICHED URANIUM METAL.

b.

This Certificate of Compliance replaces Certificate of Compliance No. 5467, Rev. 3, dated September 20, 1976. There are no changes in packaging designs. Authorized contents have been revised to reflect current shipments.

(continued on page 2) 6a. Care of issuance:4GG 1 9,a7n l 6b E=oiration Oate:

~' ~'*

FOR THE U.S. OEPARTMENT OF ENERGY Ta. Address (of 006 !sswng orrical ib. 54 nature. Name.and Titte lof DCE Aoprowng Officiati U. S. Department of Energy gm )

7m' Post Office Box E William H. Travis, Directar Oak Ridge, Tennessee 37830 i

Safety and Enviren= ental Control Division u

$. l

- __=x l'637 153 7912210 Y8 5

Certificate of Compliance No. 5467, 2

Rev. 4 3(c) E.I. du Pont de Nemours DPSE-79-71-6 June 20, 1979 and Company Savannah River Plant Aiken, South Carolina 29801 5 c.

Packaging consists of the following wooden shipping containers; which are banded with 1.25"x.035" steel banding secured by notched seals:

1.

Boxes with lids (tiLO Dwgs G-4214, G-4245, and G-4292) constructed with 1-1/8" tnick pine sices ind ends, a 1" thick hardwood bottom and 1" thick plywood lid (except G-4245 which has a 1/2" thick lid).

2.

Pallets with covers (tiLO Dwgs G-4255 with G-4256 and G-4257, and G 2273 with G-4274 ano G-4275) constructed primarily of 3/4" thick exterior grada plywocd.

In addition to tne exterior banding, bands also secure the oillets or ingots to the pallet.

3.

Pallets witnaut covers (NLO Dwgs G-4273 and G-4272).

The volumes of these containers range from s.7 to 6 ft3 and gross weignts range from 250 lbs. (113 kg) to 3240 lbs. (1469 kg). All closed containers are bandad with nine bands except tne sample container which has four bands.

See ilLO Cwgs, in Rpt. fio. NLCO-1107 for canding requirements.

Container model numbers are the same as itLO drawing numbers.

d.

The containers will be utilized only as Fissile Class III packages and will be transported cnly by motor freight and rail.

e.

The maximum 2350 enrichment of the bulk uranium is 1.25% and of tne samoles s 2.1".. Specific materials, load limits and container mixing criteria are snewn in Attachment "A".

f.

Tne maximum 235U enrichment of uranium metal scrap fragments dispersed in con-crete billets is 1.25%. The billets are contained witnin a steel container naving a wall tnickness of approximately 0.010" tnick (lard can).

Load limits are snown in Attacnment "B".

g.

(1) The maximum U-235 enricament of scrac uranium metal as extrusiens, bcita sections or fragments in tne Uti!-ST-1 shipping tuce is i.25%.

Dimensicns of extrusions are as folicws:

Fuel Extrusions 0.D. (in.)

I.D. (in.)

Cuter 2.391-2.435 1.691-1.779 Inner 1.237-1.296 0.431-0.492 Reject extrusiens will have lengtns 23".

Sections <3" in length shall :e col:ec togetner to fom lenctns 23" as folicus:

Lencth of Ecl:ed Section (in.1 301: diameter (in.)

s 12 3/8

> 12 < 2a 1/2

_ 2a

'3/3 i

1637 154

Certificate of Compliance No. 5467, 3

Rev. 4 Washers shall be used over the metal op.enings to hold sections together as appropriate with a cotter pin positioned in the bolt to hold the nut on the bol t.

(2) A close packed configuration shall have the uranium in contact with no physical separations (such as fuel supports) and with no gaps or spaces within the interior of the packing. The uranium will normally be parallel packed but cross packing to fill the ends of the boxes shall also be permitted.

Contents shall be tightly shored inside the box to maintain the close pack configuration. The following describes close pack and loose pack versus lattic pitch (L.P.):

Fuel Extrusion Cicse pack Loose pack L.P. (in.)

L.P. (in.)

Inner 2.5 2.7 Outer 1.4 1,77 be packaged in the UNI-ST-1 shipping tube, 2" (inside) peel test samples sh (3) Segments and other pieces of extrusions including dia, and snipped in the NLO boxes the same as uranium fuel extrusions. The shipping tubes will be loaded in the boxes in up to four layers of five tubes each in MLO box G-4214 and up to eight layers in box G-4292. A cotter pin is positioned in tne open-ing end to assure that the screw cap remains in position.

(4.) The uranium metal scrap shall be loaded in NLO boxes in the method described in UNI-483, Rev.1 and UNI-489, according to the loading limits and restrictions noted in Attachment "C".

(5) For shipments consisting of mixed boxes and materials, the sum of the safe fraction per box (1/C) for all boxes in the shipment shall be s 1.00.

1/C is determined by dividing the safe number of boxes (C) for the material type, en-richment and mass per box into 1 as specified in Attachment "C".

(6) The following specific materials may be shipoed in unlimited cuantities:

235U enrichments 5 25" when packaged in shippiiig 1

a.

uranium fragments at tubes UNI-ST-1.

2350 enrichments $.25% either bolted 1

b.

inner uranium fuel extrusions at or unbolted in close packed configuration.

c, outer uranium fuel extrusions at 235U enrichments 50.95P. when bolted and in close packed configuration.

1637~ liS5

Certificate of Compliance No. 5467 4

Rev. 4 (7) For the packaging and shipment of Mark VR, VE, and 15 cores and slugs:

a.

Axes will be vertical in the boxes.

b.

Mass limits per box arid total mass limits of uranium per shipment are shown in Attachment D.

c.

Boxes will be shipped in a single layer on the vehicle.

d.

Only one material type will be shipped at a time, except:

1.

Mark 15 inner bare cores may be shipped with Mark 15 inner bare cores.

2.

Mark 15 outer bare cores may be shipped with Mark 15 outer canned slugs.

1637 156

t

+

Certificate of Compliance No. 5467, Rev. 4 ATTAOU4 Ell? "A" fM imum Cantainer Vehicle I,imite

% 2nkl H14 Dwg.

Nass/ Container No. of Mass Ites.

A terial Enriclunent No.(s) lb.

k.

Containers Ab.

kg.

Comalng11pg 8

tu.

1.

ILE Cores 0.95 G-h21h 1800 816 Un11atted ip11mited With all others or with natural

( 1. k" 0.D.

0.5" I.D.

or depleted U metal 6"1) 2.

N Billuta or 0.95 G le21% or Un11mited Un11alted Un11a16ed With alf others or with natural similar rods G-4255(A) or or tubes (OD-ID)

G4273(B) or depleted U metal i 3.5" 3.

5 Billets or 1.25 G-h21% or Un11ulted Unlialted 58,000 26,300 With all others or with natural or alall st rods or G-k255(A) or tules (OD-ID)/2 G-4273(B) depleted U metal (D)'

2 2.0" N In60ts (CD-ID) 2 3.5" 0.95 G-k273(B) or Unlimited Un11mited Unlaatted With all others or with natural or G-427%(C)

G-4292 depleted.U metal 5.

N Indots (C4-ID)/2 1.25 0-(273(B) or Unlimited Unlimited 58,000 26,300 With all others or with natural or

?. 2.0" G-k2l4(C) or G4292 depleted U metal (D) 6.

Samples 2.1 G-k2k5 225 102 1

225 102 With all others or with natural or depleted U metal Footnotes:

A.

G-4255 with G-4256 and G-4257 D.

G4273 with G-4274 and G-4275.

C.,

G-k273 with G-4274 D.

Vben iter.2 3 and 5 are shipped together the total of both is to be limited to 58,000 lbs. (26,300 kg)

U N

N

Certificate of Compliance No. 5467,

.ATTACUMENT "B" Rev. 4 CLAS3 III SHIPPING LIMITS FOR URA'TIU'1 CCNCRETE BILLETS NLO E0X TYPE OF

30. OF URANIUM /30X SAFE NO. OF CLASS III TYPE BILLET
  • BILLETS /30X lb.

kz.

BOXES / VEHICLE G-4273 A

1 100 k5.h 10,8kT A

2.

200 90.7 1,324 w

A 3

300 136.1 386 A

4 400 181.5 161 A

5 500 227.0 80 A

6 600 272.2 kT G 4292 A

1 100 45 5 h,490 A

2 200 90.7 551 A

3 300 136.1 162 3

1 200 90.7 kT9 B

2 h00 181.5 59

" Type A - 25 lb. lard can 7/8" I.D. x 10-1/k" high 0.k5 ft3 volume Type 3 - 50 lb. lard can - ll-1/k" I.D. base x 12-1/h" I.D. =cuth 3

x 15-1/2" high - 0.97 ft volu=e.

9

Attachment "C" Cettificate of Compliance No. 5467, Rev. 4 SAFE iluMBER OF BOXES (C)VS i4 ASS OF URAtlIUti PER BOX (ii)_

MA IV Inners 0.95%235U-i4K IV Inners 0.95% 235U HK IV Outers 0.95X 2350 dox G-4292, L.P. = 1.77 in.

Box G-4292, L.P. = !.77 in., Bolted Box G-4292, L.P. = 2.5 in.

I4 C

C C

lb. of Safe fio.

Safe flo.

Safe f{o.

U/ Box of Boxes of Boxes of Boxes 200 2345 14632 7977 300.

677 4316 2341 400.

280 1815 980 500.

141 927 499

600, 81 535 287 7r 3.

50 336 180 800.

33 225 120 900 23 158 84 1000.

17 115 61 1100.

12 86 46

~

1260 9

66 35

1300, 7

52 28 1400.

6 42 22 1500.

S 34 18 15 tlK IV Inners 0.95% 2350 MK IV Inners 0.95% 235U 14K IV Outers 0.95% 2350 Box G-4214, L.P. = 1.77 in.

Box G-4214, L.P. = 1.77 In., Bol ted Box G-4214, L.P. = 2.5 in.

M C

C C

lb. of Safe flo.

Safe No.

Safe tio.

UjBox of Boxes of Boxes of Boxes 200.

1010 6226 3403 300.

294 1839 1001 400 122 774 420 m

500 62 396 214 W

600 35 229 124 N

700.

22 144 78 800.

15 96 52 L.P. - Lattice Pitch

Certificate of Compliance No. 5467, Rev. 4 ATTACilMEllT C Page 2 MK IV Outers 0.95% 23sU HK IV Outers 0.95% 235U HK IC Outers 0.95% 235U Hox G-4292,t..P. = 2.7 in.

Box G-4292,l..P. = 2.7 in.. Bolted Box G-4292. L.P. = 2.7 in.

H C

L C

lb. of Safe flo.

Safe flo.

Safe flo.

U/ Box of Boxes of Boxec of Boxes 200 2709 11744 2210 300.

788 3465 644 400.

328 1457 269 500 166 744 136 600.

95 429 78 700 59 270 49 800.

40 181 33 900.

28 127 23 1000 20 92 16 1100 15 69 12 1200.

11 53 9

1303.

9 42 1400.

7 33 ItK IV Outers 0.95% 2350 MK IV Outers 0.95% 2350 MK IC Outers 0.95% 2350 Box G-4214, L.P. = 2.7 in.

Box G-4214, L.P. = 2.7 in., Bolted Box G-4214, L.P. = 2.7 in.

M C

C C

lb. of Safe flo.

Safe flo.

Safe flo.

U/ Box of Boxes of Boxes of Boxes 200.

1163 4993 948

~

m 300 340 1476 278 U

400.

142 621 116 N

500.

72 318 59 n

600.

42 184 34 700.

26 115 CD

Attaciunent "C" Certificate of Compliance No. 5467, Rev. 4 MK IC Outers 0.95%235U 11K 1A Outers 1.25%23s0 MK IA Outers 1.25%2350 isax G-4292. l..P.

- 2.5 in.

Box G-4292, t..P.

= 2.7 in., Bolted Box G-4214, L.P. = 2.7 in.

M C

C C

lb. of Safe No.

Safe No.

Safe No.

U/ Box of Boxes of Boxes of Boxes 200.

4907 726 175 300.

1438 206 49 400.

602 84 20 500.

306 42 10 600.

176 24 6

700.

110 15 800.

14 10 900.

51 7

1000.

37 5

1100.

28 3

1200.

21 3

1300.

17 1400.

13 MK IC Outers 0.95%2350 MK 1A Outers 1.25% 2350 MK IA Outers 1.25%2350 Box G-4214, L.P. = 2.5 in.

Bos G-4292, L.P. = 2.7 in.

Box G-4214, L.P. =2.7 in., Bolted M

C C

C lb. of Safe flo.

Safe flo.

Safe flo.

g/ Box of Boxes of Boxes of Boxes -

200 2097 393 317 300.

616 108 91 400 258 43 38 O

500.

132 21 19 W

600.

76 12 11 Y

700.

48 7

(10 0 5

m$

900.

3 1000.

2 1100.

1 1200.

1

Certificate of Compliance No. 5467, Rev. 4 Attactnent "C" Page 4 f1K IA Outers 1.25%2350 MK IA Outers 1.25%235U Box G-4292, L.P. = 2.5 in.

Box G-4292, L.P. = 2.5 in., Bolted M

C C

lb. of Safe flo.

Safe flo.

UfBox of Boxes of Boxes 200.

820 1803 300.

230 520 400.

93 215 500.

46 108 600.

26 62 700.

16 38 800.

10 25 900.

7 18 1000.

5 13 1100.

4 9

1200.

3 7

1300.

2 6

1400.

2 4

MK IA Outers 1.25%2350 MK IA Outers 1.25%235U Box G-4214, L.P. = 2.5 in.

Box G-4214, L.P. = 2 5 in., Bolted il C

C lb. of Safe flo.

Safe tio' U/ Box of Boxes of Boxe 200.

360 778 300.

102 226 400.

42 94 500.

21 48 fV 600.

12 27

/00.

7 17

Attachment D Packaging and Shipping Limits for Mark VR, VE and 15 Cores and Slugs MAXIMUM WCIGHT MAX AMOUNT BOX TYPE, NO. PER B0X, PER BOX, POUNDS OF U PER MATERIAL TYPE NLO ORAWING NO MAXIMUM NET GROSS SHIP., TONS s

Mark VR inner canned G-4214 105 1070 1125 6.9 slugs Mark VR outer canned G-4214 45 650 705 16.3 slugs Mark VE inner canned G-4214 105 1010 1065 3.4 slugs Mark VE outer canned G-4214 45 610 665 3.4 slugs Mark 15 inner bare G-4292*

60 980 1080 1.3 cores Mark 15 inner canned G-4292*

60 1015 1115 4.1 slugs Mark 15 outer bare G-4292*

30 580 680 1.3 cores Mark 15 outer canned G-4292*

30 610 710 4.1 slugs

  • A wooden false bottom will be placed in each box to reduce the inside useable height from 161/8 to 11 1/2 inches.

2e_.m.s.,

1637 16'3

'L c46

p. fMs.

.Ci;-

Departrnent of Energy W

Savannah River Operations Office n;, f PO Box A Aiken, South Carolina 29801 JUL ? 01979

~

y,y,1.-

M. J. Sires, Director Q;,

~ ' ' -

Technical and Production Division SUPPLEMENT TO SAFETY ANALYSIS REPORT NLCO-1107 (YOUR MEMO, 7/9/79, TS:WGO'Q: Img) nte supplement to Safety Analysis Report, NLCO-1107, has been reviewed for nuclear criticality safety (memo, DES /DNB, 7/19/79).

It is concluded that the return of the Mk VR, Mk VE, and Mk 15 slugs in the original wooden boxes will satisfy the requirements of SR-0529 and 10 CFR 71.

The limitations as described in the SARP supplement will ensure nuclear

' I' ' "

criticality safety. Approval of the SARP supplement is recommended by the Safety and Environment Division.

p v

W<.A. Re s, Director EN: DES:djb Safety and ' Environment Division m

l' e.

~

e

.s..

~

1637.164

u l

JC s

%i'.

T JUL 191979 D. N. Bridges, Chief

    • "J '

Nuclear Safety Branch w

SUPPLEMEVr TO SAFETY ANALYSIS REPORT NLCO-1107 i

Building 777-M is being placed in a shutdown condition.

Due to the i

termination of activity in Building 777-M, a total of 36 tons of slightly enriched uranium fuel slugs and cores will be returned to National Lead of Ohio. The fuel will be shipped in the wooden containers in which

=

they were originally received. The SARP for the wooden containers and *

',,",,?

the existing Certificate of Compliance do not authorize the shipment of this uranium since the original shipment was made before current restrictions were imposed. The SARP supplement is intended to document the adequacy of the wooden containers for shipping the enriched uranium fuel.

The wooden containers would be destroyed by the hypothetical accident conditions of 10 CFR 71.

This is recognized by the SARP supplement and therefore the safety of the proposed shipment is supported by limiting m---.

the mass of uranium. The limits determined are such that if all the slugs or l ' 2 cores were arranged in the most reactive array, with water moderation, the arrangement would be subcritical.

w. _, -

"'~~~

All assumptions necessary for the criticality analysis were made in the conservative sense. The mass of 20sU in the low enriched fuel and the cylinder diameters are safely below the maximum limits provided in ANSI N16.1 (Nuclear Criticality Safety in Operations With Fissionable Material Outside Reactors). The maximum safe slab thickness has been confirmed, based on an infinite, flooded array, and the actual slab thickness is within the safe limit for all cases. The requirements of SR-0529 and 10 CFR 71 for nuclear criticality safety will be satisfied for the fuel shipment proposed by the SARP supplement, DPSP-79-71-6, and its approval is recommended.

9n

-ay'_

f C VChl/

p D. E. Scott

2..,

I

EN.0ES:djb Nuc1 car Safety Engineer suuse cc:

TSP Division 1637 165

.em

.n.

r