Foem NRC418 U.S. NUCLEAR REGULATORY COMMISSloN d2 731 CERTIFICATE OF COMPLIANCE
,g c,g 7, For Radioactive Materials Packages Packaos identification No.
Pages No. 1.(e) Total No. Pages 1.(c[SA/5086/AF 1.(d) 1 1
1.(a) Certificate Number 1.(b) Revision No.
5086 1
U
- 2. PREAA,.BLE 2.(a)
This certificate is issued to satisfy Sections 173.393a 173.394,173.335, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in item 5 below, meets the safety s+andards set forth in Subpart C of Title 10. Coce of Federal Regulations, Pa rt 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Mateiial Under Certain Conditions."
2.(c)
This certificate does not relieve the consignor from compliance with any requirement of the regulations cf the U.S. Department of Transportation or other applicable regulatory agencies, including the governtrent of any country through or into which the package will be transported.
- 3. This artificate is issued on the basis of a sefety analysis report of the package design or application-3.(a)
Prepared by (Name and address):
3.(b)
Title and identifict, tion of report or application:
United Nuclear Corporation United Nuclear Corporation application dated 67 Sandy Desert Rd.
January 3,1967, as supplemented.
Uncasville, CT 06382 3.(c) oocket No.71-E086
- 4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart C of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Oth r Conditions, and
References:
(a) Packaging (1) Model No : UNC-2600 (2) Description The inner container is an 11-gage steel box 96" long with'a 25 squara inch maximum cross section. The inner container is supcorted in a 221/2" ID by 101" long 14-gage steel drum by an insertable cage formed by nine 21 1/2" diameter by 3/8" thick steel plates spaced approxiattely 12" apart, with a channel formed through the center of the plates by angle iron. The outer container closure is mace with a 14-gage or heavier drum lid with bolt locking ring utilizing not less than 5/8 inch diameter steel bolt or lock nut.
(3) Drawings The packaging is constructed in accordance with United Nuclear Corporation Drawings E-20354, Sheets 1 through 5.
Outer container closure shall be made in accordance with the United Nuclear Corpora-tion application dated January 3,1967.
1 6'3 6-2 9 4 7912210
- Page 2 - Certificate No. 5086 - Revision No.1 - Docket No. 71-5086 i
t 5.
(b) Contents (1) Type and form of material (i) Dry uranium-zirconium, uranium-aluminum alloys and compounds with densities not exceeding 1 kg U-235 per liter in the form of plates or sheets. Uranium may.% enriched to any degree in the U-235 isotope.
Dry uranium oxide pellets encapsulated in stainless steel, (ii) aluminum or zircaloy rods.
Uranium may be enriched to a maximum 5.0 w/o in the U-235 isotope.
(2) Maximum quantity of material per package Ten (10) kilograms U-235 and the net weight of the contents not to exceed 308 pounds.
(c) Fissile Class II and III (1) Minimum transport index 10.0 to be shown on label for Class II (2) Maximum number of packages Ten (10) per shipment for Class III 6.
The cross section of the inner container shall be limited to a maximum 19.6 square inches for the contents specified in 5(b)(1)(i) where the ratio of the weight of U-235 to the weight of U-235 plus zirconium exceeds 0.074 or the ratio of the weigr~ of U-235 to the weight of U-235 plus aluminum exceeds 0.22.
7.
The package authorized by this certificate is hereby approved for use under the general license provisions of Paragraph 71.121,b) of 10 CFR Part 71.
8.
Expiration date: October 31, 1981.
REFERENCES United Nuclear Corporation application dated January 3,1967.
Supplements dated: January 24, 1967; and June 14, September 11, and December 4, 1968.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION 66 &2/s O Charles E. Mac0cnald, Chief
' Transportation Certi-fication Branch Division of Fuel Cycle and 0M Date:
1636 295