ML19211A861
| ML19211A861 | |
| Person / Time | |
|---|---|
| Issue date: | 11/06/1979 |
| From: | Potapovs U NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Strelczyk P VELAN VALVE CO. |
| Shared Package | |
| ML19211A864 | List: |
| References | |
| REF-QA-99900346 NUDOCS 7912210196 | |
| Download: ML19211A861 (2) | |
Text
y.
- -f-
< ~=s' W / K Z d C Y
^x/
UNITED STATES e[v afog%
NUCLEAR REGULATORi COMMISSION
{
^
O REGloN IV
^p
$ l o
611 RYAN PLAZA ontVE.SulTE 1000
.*J
..L j ARLINGTON, TEXAS 76012 o.,
?...../
6 NOV 1979 a
Docket No. 99900346/79-02 Velan Valve Corp.
Attn:
Mr. P. Strelczyk Vice President & Plant Manager Avenue C, Griswold Industrial Park Williston, Ver=ont 05495 Gentlemen:
This refers to the QA Program inspection conducted by Mr. William D. Kelley of this office on October 16-18, 1979, of your facility at Williston, Vermont associated with the manufacture of ASME "N" Class 1, 2, and 3 valves and to the discussion of our findings with Mr. E. I. Francois of your staff at the con-clusion of the inspection.
This inspection was made to confirm that, in the areas inspected, your QA program is being effectively implemented. The inspection effort is not designed to assure that unique quality requirements imposed by a customer are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality. As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others. You should therefore not conclude that the NRC's inspection exe= pts you from inspections by an NRC licensee or his agents nor from taking effective corrective action in response to their findings.
Areas examined during the inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.
Within the scope of this inspection, we found no instance where you failed to meet NRC requirements.
1636 105 U12210 /9(
Velan Valve Corp. In accordance with Section 2.790 of the Commission's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter together with the enclosed inspection report will be placed in the Commission's Public Document Room.
If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure.
Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the docu=ent.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, 1
y Uldi " tapovs, Chi f Vendor Inspection Branch
Enclosure:
Inspection Report No.
99900346/79-02 1636 106