NhV 231979 MEMORANDUM FOR:

D. Ziemann, Chief Operating Reactors Branch #2 Division of Operating Reactors FROM:

G. Lainas, Chief Plant Systems Branch Division of Operating Reactors

SUBJECT:

BIG ROCK POINT FIRE PROTECTION:

DESIGN DETAIL REVIEW Plant Name: Big Rock Point Licensee: Consumers Power Company Docket No..

50-155 Project Manager:

R. Silver Status: See attached status sheet.

By letter of August 31, 1979, Consumers Power Company provided certain design criteria as mquested by our Fire Protection SER of April 4, 1979, for the fallowing proposed modifitations:

3.1.3 Fire Barrier Penetrations; 3.1.23 Recirculation Pump Area Sprinklers; and 3.1.26 Protection of Reactor Depressurization System (RDS) Cables. We have reviewed these design criteria and find that: an adequate number and type of fire detectors will be installed in appropriate locations; hose connections and isolation valves will be provided to bypass breaks in the fire pump header; an adequate cable penetration fire stop design will be used; an appropriate water spray system will be installed for the recirculation pump oil hazard; and adequate barriers are being installed to protect RDS cables. Additionally, these modifications are being designed in accordance with appropriate NFPA standards. On this basis, we find that the design of these modifications provides the protection we intended in preparing our SER. nccordingly, we find the design criteria for these modifications to be acceptable.

Fire protection engineering support for this review was provided by DSS.

d-D+ ~

f

. Lainas, Chief G

Plant Systems Branch Division of Operating Reactors

Enclosure:

As stated cc: See next page 7 9122001 13

D. Ziemann NOV 2 31979

Contact:

H. George, X27136 cc w/ enclosure:

D. Eisenhut R. Vollmer G. Lainas V. Benaroya G. Harrison S. Hudson R. Ferguson T. Wambach R. Silver H. George 1632 339

Enclosure STATUS -

BIG ROCK POINT FIRE PROTECTION Status 3.1 Design Criteria Review:

3.1.1 Alternate Safe Shutdown System 1/

3.1.3 Fire Detection System Complete 3.1.4 Fire Pump Header Complete 3.1.13 Fire Barrier Penetrations Complete 3.1.23 Recirculation Pump Area Sprinkler Complete 3.1.25 Shutdown Cooling Valves Complete 3.1.26 Protection of RDS Cables Complete 1/ Delayed for SEP 3.2 Incomplete Items:

3.2.1 Fuel Pool Cooling Under Review 3.2.2 Fire Brigade Under Review 3.2.3 Cabling in Recirculation Pump Area Under Review 1632 340

.