Forwards Revised Pages of Consolidated License Application for Exxon Nuclear Model 51032-1 & 1a Shipping Containers
ML19211A493
Person / Time
Site: 07106581
Issue date: 11/30/1979
From: Hansen L
SIEMENS POWER CORP. (FORMERLY SIEMENS NUCLEAR POWER
To:
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML19211A494 List:
References
14897, NUDOCS 7912200008
Download: ML19211A493 (7)


Text

fD8 11-65SI ERON NUCLEAR COMPANY,Inc.

RESEARCH AND TECHNOLOGY CENTER 2955 George Washington Way, Richland, Washington 99352 PHONE: (509) 375-7100 November 30, 1979 Mr. C. E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Reference:

1) Docket No. 71-6581
2) Certificate of Compliance No. 6581 3)

Iatter, C.

E. MacDonald to W.

S. Nechodom, dated Octcber 18, 1979.

Dear Mr. MacDonald:

Please find enclosed eight copies of revised pages for the Consolidated License Application for Exxon Nuclear Model 51032-1 and -la Shipping Containers", XN-52, Revision 1.

Guides for inclusion of the revised pages in your version of XN-52, Rev. 1, dated June 1979 are included with each set of revised pages.

Responses to each of your specific requests / comments / questions are given below:

Structural 1.

Provide a listing of the licensing drawings for each of the two models of the packagings.

Indicate the Drawing No.,

Sheet No.,

and Revision No. for each drawing.

A listing of the licensing drawings for the tuo packaging models is provided in Attachment 1.

Craving, sheet, and revisicn nic-bers are given for each.

2.

Provide a copy of each licensing drawing. Each drawing should indicate the Drawing No., Sheet No., Revision No., and the Model No. of the packaging.

The present drawings are not legible, do not indicate all safety features, contain extraneous material, and are uncrganized (number of drawings should be reduced to a minimum).

G:anges have been made to a me",bcr of the drawings to i~prcve the clarity. 17te secuence of presentaticn uas mcdified somewhat and the n:c-ber of drauings reduced as arprcariate.

  1. ne text of Sections 2, 5, :O and Appendi= 7 were changed to reference the revised drawings.

AN AFFILI ATE OF EXXON CO RPOR ATION 7 91e2ootoF 14897 1631 130

C. E. MacDonald November 30, 1979 Some extraneous material is still presented in the drauings, but the level of detail of such information is reduced.

We believe that all safety related details are nou shctm.

3.

Identify the changes made to any of design features shown on the revised drawings from the currently approved design and show that the modified design meets the requirements of 10 CFR Part 71.

Design changes shoun are indicated in Attachment i and reference is made to the location in the a: plication uhere the safety related effect of the design changes is discussed.

Each change has been shown to meet the requiremeMs of 10 CFR 71 either by separate evaluation or evaluation versus the features of the currently licensed packages.

Criticality 1.

Provide specific details of each experimental array used to support the calculational methods in the criticality safety analyses.

De-lineate all simplifying assumptions made and adjustments made to obtain the reported results.

Additional details of benchmark calculations used to support the criticality safety calculaMonal methods is provided by the inclu-sion of document XN-NF-499, " Criticality Safety Benchmark Calcula-tions for Lo:>-Enriched Urani:e Metal and Uranium C=ide Rod-Water La ttices ". That document (Reference 7) is referenced in Sections 12.1. 3.1 and 12.1.3. 2 and three (3) cocies are enclosed herewith.

The list of references, Section 13, is' changed accordingly.

2.

Provide appropriate copies (3) of References 4 and 6.

Three (3) copies of each of those references are enclosed.

With respect to our application for renewal, please be reminded that the extension is valid only until January 31, 1980.

Due to our need to maintain a valid IAEA Certificate of Compentent Authority for these shipping container models your early review and approval of this appli-cation is desired.

If you have any additional questions or if addi-tional information is needed to complete your review, please contact me on (509) 375-7288 at the earliest possible time.

Sincerely, L

1631 131 L. E.

Hansen, Senior Specialist criticality Safety and Physical Security LEH: sir Attachments

ATTACIIMENT 1 LICE!JSIt1G DRAWINGS Ref. Fi. jure Applicable Changes from Currently Change 11 umber Drawing Number Package Model(s)

Licensed Package Justification 2.3 XN-NP-303,359 51032-1 & -la No design changes -

Not applicable.

Sheet 1, Rev. I redrawn for clarity.

2.4 XN-NP-303,360 51032-1 & -la No design changes -

Not applicable.

Sheet 1, Rev. 1 redrawn for clarity.

2.5 XN-NF-303,898 51032-1 No design changes -

Not applicable.

Sheet 1, Rev. O redrawn to delete some non-safety related details.

2.6 Jti-300,607 51032-1 No change.

Not applicable.

Sheet 1, Rev. 0 2.7 XN-NF-303,891 51032-1 New strongback design -

See Section 10.1.2.3, Sheet 1, Rev. O reduced length.

for justification of the strongback design.

2.8 JN-600,843 51032-1 11 0 change.

flot applicable.

Sheet 1, Rev. 3 2.9 JN-600,844 51032-1 No change.

Not applicable.

Sheet 1, Rev. 2 2.10 XN-NF-303,890 51032-1 No design change -

Not applicable.

u Sheet 1, Rev. O some non-safety BO related details were deleted.

ATTACitMENT 1 (Continued)

LICENSING DRAWINGS (Continued)

Ref. Figure Applicable Changes from Currently Change Number Drawing Number Package Model(s)

Licensed Package Justification 2.11 XN-NF-300,609 51032-1 No design changes -

Not applicable.

Sheet 1, Rev. 1 redrawn to include speci-fication of materials and thrust plate details.

2.12 XN-NF-303,364 51032-1 & -la No design changes -

Not applicable.

Sheet 1, Rev. 1 redrawn for clarity and to show applicability to both packaging models.

2.13 XN-303,897 51032-1 Includes aluminum BWR clamp See Section 10.1.2.2 Sheet 1, Rev. O assembly design & consoli-for justification of dates packaging details the aluminum clamp design, for BWR fuels.

2.14 XN-NP-303,357 51032-la No design changes -

Not applicable.

Sheet 1, Rev. 1 some safety related infor-mation was added and non-safety related information was deleted.

I 2.15 XN-NF-303,354 51032-la No design changes - redrawn Not applicable.

Sheet 1, Rev. 2 to delete non-safety related detail and include safety related information from Cys (fa sheet 2 of the prior drawing.

Led

ATTACHMENT 1 (Continued) 1 LICENSING DRAWINGS (Continued)

Ref. Figure Applicable Changes from Currently Change Number Drawing Number Package Model(s)

Licensed Package Justification 2.16 XN-NP-303,357 51032-la Basic design remains See Section 10.2.4 Sheet 2, Rev. 1 unchanged. Washer size and Appendix V, page increased for additional V-2 & Section V.5 for joint strength.

justification.

2.17 XN-NP-303,356 51032-la No design change - title Not applicable.

Sheet 1, Rev. 1 change and minor deletions of non-safety related details.

2.18 XN-NF-303,818 51032-la Aluminum clamp design for See Appendix V, Sheet 1, Rev. O packaging BUR fuel elements.Section V.4 for justification.

2.19 XN-NP-303,755 51032-la No design changes -

Not applicable.

Sheet 1, Rev. I revised for clarity of packaging detail and title change.

2.20 XN-NF-303,358 51032-la No design changes -

Not applicable.

Sheet 1, Rev. 1 redrawn for clarity.

Lc4 esummmmD 4

e ATTACHKENT 2 SUM &WY OF CHANGES TO XN-52, REVISION 1 Section No.

Pace No (s).

Cliange Summarv 2.1.1 2-4 (1st para.)

Added reference to Section 2.1.2 for calculation of minimum separator block requirement.

2.1.1 2-6 Added reference to Figure 2.12 in next to last paragraph of Section.

2.1.2 2-5 to 2-8 The title of the section was changed and references to figures revised as appropriate. Wording was changed as needed due to the inclusion of information from 3 figures onto 1 figure. Minimum separator block requirements were included.

2.2.1 2-8 to 2-9 Wording revised for clarity of presentation and references to figures were revised as appropriate.

2.2.2 2-9 to 2-10 Same as Section 2.1.2 changes, except applicability is to the Model -la package rather than the

-1 package.

Figures 2-22 to 2-41 Revised as indicated in Attachment 1.

5.0 5-2 Wording revised for clarity.

I 10.1.2.2 10-6 Reference figure number changed.

10.2 10-10 Reference figure number changed, and wording revised for clarity.

10.2.4 10-14 Reference figure number changed.

12.1.3.1 12-6 Additional reference data provided.

12.1.3.2 12-6 Same as for 12.1.3.1.

Remainder of 12-7 to No change. Pagination af fected due Section 12 12-27 to changes in Section 12.1.3.1 and 12.1.3.2.

Appendix V V-1, V-6, Reference figure numbers changed.

V-8 & V-9 1631 135

GUIDE FOR INCLUSION OF REVISED PAGES OF XN-52, REVISION 1 1.

Replace the title page and pages il through xii with attached pages having an identical numbering sequence.

2.

Replace Section 2 (all pages, including drawings) with the attached Section 2.

3.

Replace Section 5 (all pages) with the attached Section 5.

4.

Replace pages 10-6, 10-10, and 10-14 of Section 10 with the attached pages 10-6, 10-10 and 10-14.

5.

Replace pages 12-1 through 12-27 of Section 12 with the attached pages 12-1 through 12-7, 6.

Replace page 13-1 (Section 13) with the attached page 13-1.

7.

Replaces pages V-1, V-6, V-8 and V-9 of Appendix V with the attached pages V-1, V-6, V-8 and V-9.

h

.