ML19210E644

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 9085,Revision 1 for Model Sentinel 85
ML19210E644
Person / Time
Site: 07109085
Issue date: 04/07/1978
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
References
NUDOCS 7912050455
Download: ML19210E644 (4)


Text

b-Form NRC418 U.S. NUCLE AR REGUL A70RY CO'.*VISSIC'J CERJIFICATE OF COMPLIANCE FR 'il For Radioactive Yaterials Pa:= ages

=

i 1.f a) Certif,cate Nureter 1.tbl Revesson No.

1.f c) Pactace Identification No.

1,tal Pages ho 1 fel To:af No. P:

9085

~ l USA /9085/B( )

1 2

2. PRE AMat.E 2.f a) This certif;cate is inued to satisf y Sections 173.0334.173 394.173.335. and 173.*,36 of t*, Ce:ar-- ent of Tra-soc u:.:n e82:2r:

i-Materials Regulations 49 CFR 170129 anc 14 CF'1103) ane Se::icas 146-19-1Ca and 145-13-1C3 of :ne On:a-r.: =f Transporta: son Cancerous Car;oes Regulations 446 CFR 146-149). ss amenoec.

2.!b)

The Dacus;ing and contents described in item 5 below, met:s tne saferv ::ancards set fort % in 5 to,rt C of Ti:te 13. C:ce of

(

Federal Regulations. Part 71. **Pacuaging of Raoicactrve Materials for Trae::or: and TranscrJrtation or Racioacine *.*- e.se unce Certain Conostions."

2.(c)

This certifacste coes not relieve the cons 6;nor from comoiiance with any recuire me9t of the regulations of tne U.S. Oeoa tr ent o*

Transportation or other apolicaofe regulatory agencies, includang :ne governraent of any country :nrough or into w ecs tne cacua; FW De transportad.

~

3. This certificate is issueo on the be:is of a safety analysis report of tre cackage desegn or aposication-

~

3.(a)

Prepared tv (!!arne and aderen):

3.13)

Tide anc Idantifica: ion of report or as lica:.on-Teledyne Energy Systems Teledyne Energy Systems application 110 West Timonium Road dated March 3, 1977, as amended.

,Timonium, Faryland 21093 3.rei cocnet No. 71-9085 4 CC..cs! ONS This certificate is conditional upon the fulfilling of the requirements of Suocart D of 10 CFR 71. as acolicaole. and the c:. i: 09s s:ecifi.

in item 5 cefow.

5. Descnotion of Packa;ing and /.uthorized Contents. Model Numoer. Fissise C:au. Otner Conditions. anc Referen:es.

(a)

Packaging me (1) Model No.: SENTINEL 8S D

oD eo oj j

rt (2) Description i

The packaging contains a thermoelectric generator with 55,000 Ci of strontium 90 titanate or strentium 90 f',uoride. The dimensions are 32.2 inches in height by 37.53 inches in diameter. The package is welded to a 39.5 inch square, steel pallet, which is 4 inches high.

The contents are housed in a stainless steel or Hastelloy C-276 liner. The liner, with its pressed cap, is contained within a fuel capsule (5.5" x 3.735" 00). The capsule lid is threaded for strength and welded (minimum weld penetration of 0.055" is specified) to give a y

positive seal. The wall thickness of the capsule is a minimum of N

0.3475 inches.

The fuel capsule is constructed of Hastelloy C-276 (or Uniloy HC).

The capsule is inserted into the tungsten biological M

shield (8.367" x 6.467" 0D), and the shield plug is bolted into place d

using three steel bolts, equally spaced on a 5.093 inch bolt circle.

[

The tungsten shield is held in a horizontal position within the generator's aluminum housing by the sized Min-K-1301 thermal

(

insulation. Min-K and load bearing Glasrock are used to support the shield base. A retaining ring is used to preloe.d the Min-K and to.

dampen any vibrationa.1 loads.

1497 311 i

2 9120 5 y i.s

(

Page' 2 - Certificate No. 9085 - Revision fio.1 - Docket tio. 71-9085 (2) Description (continued)

The finned 6061-T6 aluminum housing forms the outer protective shell of the generator.

Dt. ring shipment, the detachable fin extensions-will be bolted to the fins. This increases the fin diameter from s '

22 inches to 26 inches, holding the generator securely in the shi;, ping

[

cask body (5.68" min. wall thickness, ASTM A-181 grade 2 forged steel).

g The interface between the overlapping fin surfaces is coated with a i

heat transfer compound (D0W Corning 340).

The total system weigh' is approximately 7400 pounds.

(3) Drawings L..

The principal ' features of the package are shown in the drawings contained in the Teledyne Energy Systems application, dated March 3, 1977.

(b) Contents (1) Type and form of material (i) Strontium 90 titanate doubly encapsulated in a stain'less steel liner and Hastelloy or Uniloy HC capsule which meet the require-ments of special form as defined in 571.4(o) of 10 CFR Part 71.

j (ii)

Strontium fluoride (90SrF ) doubly encapsulated in a Hastelloy 2

or Uniloy fuel c'esule, with a Hastelloy C-276 liner which meets the requirements of special form as defined in 171.4(o) of 10 CFR Part 71.

(2) Maximum quantity of material per package 55,000 curies.

6.

The package authorized by this certificate is hereby approved for use under the general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.

7.

Expiration date: April 30,1982.

REFERENCE q-Teledyne Energy Systems application dated March 3,1977, as amended by Teledyne Energy Systems' letter dated March 17, 1978.

l Mo FOR THE U.S. NUCLEAR REGULATORY CCMMISSION ca ern c

Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and 7

tjq o/

.> I L Material Safety I

7 pg 071978 Date:

14621

..g-

^

~~

h DEPARTMENT OF TRANSPORTATION '

i[

i RESEARCH AND SPECIAL PROGRAMS ADMINISTRATION 2

e WASHINGTON. D.C. 2o390

,,,,,. 'pif_ M o,-

IAEA CERTIFICATE OF COMPETENT AUW ORITY

..i tc 44 n u un vor

...,. ; ')

Typei Radioactive Material Package Design

-:4;ertificate Number USA /9085/3( )

'.{, J.-5~ CS

'3

(. Revision 1) hECit This establishes that the packaging design described herein, when loaded with the authorized radioactive contents, has been certified by the National Competent Authority of the United States as meeting the regulatory requiregentsforTypeBpackagingforradioactivematerialsasprescribed in IAEA Regulations and 49 CFR 89173.393b and 173.395(e)(2) of the USA 2 Regulations for the transport of radioactive materials.

I.

Package Identification - Sentinel SS.

II.

Packaging Description - Packaging authorized by this certificate consists of a Tungsten shielded steel weld =ent measuring approximately 37 inches in diameter by 32 inches in height weighing about 7400 pounds.

III. Authorized Radioactive Cootents - The authorized contents consist of not more than 55,000 curies of Strontium-90 as strontium titanate or strontium fluoride which is doubly encapsulated to meet the requirements for special form as set forth in 49 CFR 9173.389(g), and meets the capsule requirements set forth in U.S. Nuclear Regulatory Commission Certificate of Compliance No. 9085 (Appendix A).

IV.

General Conditions -

Each user of this certificate must have in his possession a.

a copy of this certificate.

b.

Each user of this certificate, other than Teledyne Energy Syster.s, Timonium, Maryland, shall register his identity in writing to the Office of Hazardous Materials Regulation, Materialr Transportetion Bureau, U.S. Department of Transportation, Washington, D.C.

20590.

V.

Marking and Labeling - The package curt bear the marking USA /9085/B( )

as well as the other marking and labels prescribed by the USA Regulations.

VI.

Expiration Date - This certificate, unless renewed, expires on April 30, 1982.

1497 113 y

evr4 D,.,,s e a f h h

t s., u -

14621

I Certificate Number USA /9085/B( ), Revision 1 Page 2 This certificate is issued in accordance with the requirements of the IAEA and USA Regulations and in response to the April 20, 1977, petition by Teledyne Energy Systems, Timonium, Maryland, and in consideration of I

'r~

the associated information provided in U.S. Nuclear Regulatory Cocmission Certificate USA /9085/B( ) (Appendix A).

Certified by:

R. R. Rawl (Date)

Designated U.S. Competent Authority for the International Transportatica of Radioactive Materials Office of Hazardous Materials Regulation Materials Transportation Bureau U.S. Department of Transportation

" Safety Series No. 6 Regulations for the Safe Transport of Radioactive Materials, 1967 Edition" published by the International Atomic Energy Agency (IAEA), Vienna, Austria.

2Title 49, Code of Federal Regulations, Parts 100-199, USA.

Original issued in response to the April 20, 1977, petition by Teledyne Energy Systems, Timonium, Maryland.

Revision 1 issued to incorporate Revision 1 of USNRC Certificate Number 9085 and to extend expiration date.

1497 314 o

e i i