Text
._
<, PACIFIC GAS AND ELECTRIC COMPANY ATTACHMENT 2 COPY
~
~
C March 27, 1979 Mr. R. H.
Engelken, Director Office of Inspection and Enforcement Region V U.
S. Nuclear Regulatory Commission 1990 N.
California Boulevard Walnut Creek Plaza, Suite 202 Walnut Creek, Ca ifornia 94596 Re:
Docket No. 50-133 License No, DPR-7
Dear Mr. Engelken:
Pursuant to Section IX.I.l.b of Appendix A to the Humboldt Bay Un.it No. 3 Facility Operating License, we are submitting a tabulation of personnel exposure to radiation, distributed among various groups and work functions.
Very truly yours, Philip A. Crane, Jr.
RCParker/ PAC:TC Enclosure bec w/ enc.:
CPUC Application No. 41212 bbec w/ enc.:
RFCayot EWeeks (Humboldt Plant) 4g4 jg4 1
0 7912 050 3 bf
h TABULATTbF PEPS 0NNEL EXPOSURE, O
1970 Nunber of Personnel and Man-Ren by Work and Job Punction for
_..7_...
1 Number of Personnel (>100 mrem)
Total Pan-Rem I
tontract
~~~ 7 ntract~
~
Utility Workers and Utility f
l WORK AND JOB IUNCTION-Station Emp.
Emplovees Othe rs Station Emp.
iEmployees Reactor Operations and Surveillance
~
Maintenance Personnel 0
0
'O 0
0 0
. Operating Personnel 23 0
0 94 0
0 1
0 0
1.0 0
0 Health Physics Personnel 0.6 0
0 3
0 0
Supervisary Personnel 3
0 0
l1 0
0 Eneineering Personnel Routine Maintenance
', tjaintenance Personnel 15 0
0 9.3 0
O
.. Operating Personnel 0
~
0 O
O o
0 1
~
Health Physics Personnel.
0 0
0.6
'O O
Supervisory Personnel 0
0 0.4 0
0 y
o_
Engineering Personnel 0
0 0.5 0
0 t
I
' Inservice Inspection'
. Maintanance Personnel 0-0 0
0 0,
o 0
0 0
0 o
l 4
Operating Personnel 0
-A
- Health Physics Personnel
-0 0
0 0
o f
0
'4 Supervisory Personnel 0
0'
-0 0
0 4
'E'ngineering Personnel 0
.0 0
0 0,-
0 l
i CDSpecial Maintenance f-w Maintenance Personnel 3
10 15
~1.7-6.3 24.8 Operating Personnel 0
0 0
0 0
0 1.6 Health Physics Personnel 0
s 3
0 0
Supervisory Personnel 1
2 0.2 0
3.3 g
~
Engineering Persennel 1
0 3
0.2 0
1.9
?
Note: All exposuren are rounded of f to the nearest 100 milli-rem, and that the number of personnel in each' category is dist ributed to reflect the distribution of manpower between,iobs.
The "special naintenance" during 1978
-.. ch.,. -,,1.
4 - o r 6,,
.i,,,,,,osw,,,,,,.,,,,,,s.,,,,
.,,,,,,,,,.,,,, a ew,
- v..,,, 4,. co es. c..a...,on,,i.
TABULATION O ERSONNEL EXPOSUPE (cont) 1978
=
I)Y &DYD "D N b.
n l
Number of Personnel (>100 nrem)
Total ? fan-Rern l
Lontract ntract Utility aorke rs and l
Utility tJorke rs and
' WORK AND J03 FUNCTION '
Station Emp.
Enplovees Others Station Emp.
Employees others i
Construct]on 0
121.9 78.7 l'aintenance Personnel 0
46 41 0
0
'O Operating Personnel 0
o o
1.2 o
7,4 1
o 9
llealth Physics Personnel 0.5 11.0 6.6 1
7 4
l' Engineering Personnel Supervisery Personnel 1
9 24 0.6 11.8-13.1 Waste Processing
? fair.tenance Personnel 0
2 0
0 1.9 o
Operating Personnel 0
0 0
0 0
o i
llealth Physics Personnel 1
0 0
0.3 0
o 0
0 0
0 0
o Supervisory Personnel 0
0 0
0 0
0 Enginee ring Pe rsonnel Re fue li n g tlaintenance Personnel 0
0 0
o 0
0 Operating Personnel 0
0 0
0 0-0 4m llealth Physics Personnel 0
0 5
0 0
0 A
Supervisory Personnel O
- 0 0
0 0
0 Engineering Personnel 0
0 0
0 0
0 CO Ch iTOTAL
~ S intenance Personnel 18 58 56 11.0 130.1 103.5 Operat ing Personnel 23 0
0 9.4 0
0 4
0 12 3.1 0
9.0 licolth Physics Personnel 7
7 6
17 11.0 99 Super fiso ry Personnel 6
9 27 2. t.
11.8 15 0 Engin. o n nn Personnel 27.6' 152.9 137.4 58 74 101
_r..n_.w n ; o : u. - -. _.
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket No. 50-133
)
License No. DPR-7 (Humboldt Bay Power Plant, Unit No. 3)
)
~
)
CERTIFICATE OF SERVICE The foregoing document of Pacific Gas and Electric Company has been served today on the following by deposit in the United States mail, properly stamped and addressed:
Linda J.
Brown, Esq.
- Robert M.
Lazo, Esq., Chairman 100 Van Ness Avenue, 19th Floor Atomic Safety and Licensing San Francisco, CA 94102 Board Panel U.S. Nuclear Regulatory Commission
- Steve Goldberg, Esq.
Washington, D.C.
20555 Office of Exccutive Legal Director Mr. Gustave A.
Linenberger, Member BETH 042 Atomic Safety and Licensing U.S. Nuclear Regulatory Board Panel Commission U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Washington, D.C.
20555
- Secretary Dr. David R.
Schink U.S. Nuclear Regulatory Department of Oceanography Commission Texas A & M University Washington, D.C.
20555 College Station, TX 77840 Attn:
Docketing and Service Section Michael R.
Sherwood, Esq.
Sierra Club Legal Defense Fund, Inc.
311 California Street, Suite 311 San Francisco, CA 94104 Dated:
October 31, 1979 h( l$
RICHARD F.
LOCKE Attorney Pacific Gas and Electric Company
- Express Mail 1494 187