ML19210D702

From kanterella
Jump to navigation Jump to search
Discusses Possible Nonconservatism in Negative Rate Trip Setpoint for Multiple Rod Drop Analyses,Reported by Westinghouse.Commits to Change Appropriate Procedures Prior to Full Startup
ML19210D702
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 11/21/1979
From: Clayton F
ALABAMA POWER CO.
To: Schwencer A
Office of Nuclear Reactor Regulation
References
NUDOCS 7911270469
Download: ML19210D702 (1)


Text

Alabama Power Company 600 North 18th Street Post Office Box 2641 Birmingham. Alab.'.a 35291 Telephone 205 323-5341 d

hboWc'e'?,MS, AlabamaPower the sournem eiectnc system November 21, 1979 Docket No. 50-348 Director, Nuclear Reactor Regulations U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Attn:

Mr. A. Schwencer Gentlemen:

RE: Multiple Rod Drop Analyses Alabama Power Company was informed, by Westinghouse Electric Corpora-tion, of a possible non-conservatism in the negative rate trip setpoint for multiple rod drop analyses. This involves revised higher error allowances for negative rate trip circuitry and potential non-conservatism of some dropped rod analyses assumptions.

Alabama Power Company commits to change appropriate plant procedures to require operation in manual control above 90 percent pouer when control rod bank "D" is below 215 steps withdrawn. Automatic control is allowed above 90 percent power when bank "D" is above 215 steps withdrawn.

The procedure changes described above will be implemented prior to reaching 90 percent power during the current Farley-1 startup.

Yours very truly, 7

a g g p )

c...

F.'L.

Clayton, Jr.

FLCJr/TNE:bhj 4

cc:

Mr. R. A. Thomas Mr. G. F. Trowbridge

\\

1398 204 k 7 9112 70 f[of