ML19210D580

From kanterella
Jump to navigation Jump to search
Forwards Revised Pages Re Proposed Amend to Tech Spec in Support of Primary Sys Chemical Cleaning.Fee Encl
ML19210D580
Person / Time
Site: Dresden 
Issue date: 11/14/1979
From: Peoples D
COMMONWEALTH EDISON CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML19210D581 List:
References
FOIA-80-347, FOIA-80-548, FOIA-80-550 NUDOCS 7911270339
Download: ML19210D580 (3)


Text

..

Commonwealth Edison One First National Plaza. Chicago. Illinois Address Reply to: Post Ofhce Box 767 Chicago, Illinois 60690 November 14, 1979 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Dresden Station Unit 1 Proposed Amendment to Appendix A, Technical Specification, to Facility Operating License DPR-2 Required to Perform Primary System Chemical Cleaning NRC Docket No. 50-10

Dear Sir:

Pursuant to 10 CFR 50.59, Commonwealth Edison proposes to amend Appendix A, Technical Specifications, to Facility Operating License DPR-2 to support the chemical cleaning of the Dresden Unit 1 primary system.

The changes to the Technical Specifications concern (1) deletion of the requirement to maintain primary containment integrity during the chemical cleaning outage when all fuel is removed from the reactor and conta inment, and (2) exclusion of radioactive liquid storage tanks which are inside seismically qualified structures from the above grade storage curie limitation.

The change to the primary containment integrity requirement is necessary to allow the chemical cleaning to be performed at the required temperature of 2500F.

Special procedures will be implemented to provide for the rapid removal of the cleaning solution to receiving tanks should a significant leak from the primary system occur.

This will ensure that any leakage will be small in volume and contained within the sphere.

Since the contamination species being removed are non-volatile and no fuel will be inside the containment, release of volatile activities due to a leak would be minimal.

Normal ventilation flow is adequate to ensure that any airborne activity will be conveyed to the stack and monitored.

The clarification of the radioactive waste above grade storage requi rement is necessary to allow transfer and storage of the spent cleaning solution prior to processing in the Chemical leaning Building storage tanks, which are physically above grade.

,e current curie limit is based upon postulated rupture of above grade tanks, due to a seismic event, allowing their contents to be released in an uncontrolled manner.

Since the tanks in the Chemical Cleaning Building are located in a seismically qualified structure sized to contain the contents of all the tanks inside that structure, the curie limit does not apply.

9

}3hh 7filMo339

,~

sa,g

Commonwealth Edison NRC Docket No. 50-10 Director of Nuclear Reactor Regulation November 14, 1979 Page 2 Pursuant to 10 CFR 170, Commonwealth Edison has determined the proposed amendment to be Class Ill. As such, we have enclosed a fee remittance in the amount of $4,000.00.

Please address any questions you may have concerning this matter to this office.

Three (3) signed originals and thirty-seven (37) copies of this transmittal are provided for your use.

Very truly yours, I

D. L. Peoples Director of Nuclear Licensing RFJ:mac enclosures S{lBSCMEED and SWOR to beforg~m6:thi) d, ay of,}&trMAM,j,1979 JM//.h/tzf1A1/

~ ~ - Aota Public d

n99 RQ