Gh

.'s h

/

TENNESSEE VALLEY AUTHORITY

.g CHATTANOOGA. TENNESSEE 37401 400 Chestnut Street Tower II October 25, 1979

[

pg gjj,

~-

Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 - ERCW ISOLATION VALVES NOT SEISMICALLY QUALIFIED - NCR CEB 79 FINAL REPORT The subject deficiency was initially reported to NRC-0IE Inspector W. T. Cottle on September 27, 1979, in accordance with 10 CFR 50.55(e).

Enclosed is our final report.

If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 854-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITY iAbd ( [

L. M. Mills, Man er Nuclear Regulation and Safety Enclosure cc:

Mr. Victor Stello, Jr., Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 l)[3 )'b 9

N5(I

!790605 COFI An Equal Opportunity Employer 7911200n.#