ML19210C913

From kanterella
Jump to navigation Jump to search
Forwards Engineering Decision Analysis Co Aug 1978 Rept, Structural Condition Documentation & Structural Capacity Evaluation of Atomics Intl Nuclear Matls Development Facility at Santa Susana,Ca,For Earthquake & Flood
ML19210C913
Person / Time
Site: 07000025
Issue date: 11/05/1979
From: Rouse L
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Kemley M
ROCKWELL INTERNATIONAL CORP.
Shared Package
ML19210C915 List:
References
REF-PROJ-M-3 NUDOCS 7911200305
Download: ML19210C913 (1)


Text

'

a,,

l p* n *Eauq'o, UNITED STATES 8'

NUCLEAR REGULATORY COMMISSION o

WASHINGTON, D. C. 20555 g

s

%,,,. e' NOV 5 1979 Project!1-3 Docket No. 70-25 Rockwell International Atomics International Division ATTN: Dr. M. E. Remley, Manager Health and Safety 8900 De Soto Avenue Canoga Park, CA 91304 Gentlemen:

The purpose of this letter is to transmit for your information an increment of the analysis of the effects of natural phenomena relative to your plutonium operations at Santa Susana, California.

The subject increment of analysis is the response of structures to earthquake hazard at your site. A draft of the enclosure has been reviewed, and commented upon, by those analysts who require the results to carry out succeeding analyses and by the NRC staff. The NRC staff has endorsed this final version of the review for application in succeeding analyses.

However, we will consider challenge of our endorsement when supported by credible technical bases.

The enclosed increment of analysis, designated as Task II, presents methcdology, basic data, and the results and conclusions of the study.

Task I, which contains the structural condition documentation on which the study is based, because of its bulk and highly technical content, has been given limited distribution. A copy is available in our offices for your inspection if you so desire.

Any comments on the enclosed analysis should be addressed to W. Burkhardt or James E. Ayer of this Branch. They will direct resolution of comments and any justifiable revision of the analysis.

Sincerely, Leland C. Rouse, Chief Advanced Fuel and Spent Fuel Licensing Branch Division of Fuel Cycle and Material Safety L1 closure:

I36I i

0 Task II 7 9112 00 3 c5 an-ee