Development of Criteria for Seismic Review of Selected Nuclear Power Plants.
ML19210C166
Person / Time
Site: Skagit
Issue date: 05/31/1978
From: Hall W, Newmark N
ILLINOIS, UNIV. OF, URBANA, IL
To:
References
Download: ML19210C166 (78)
Testimony of Nm Newmark Re Conservatism of Seismic Design Criteria & Seismic Design Provisions for Facility.Biography Encl
ML19210C163
Person / Time
Site: Skagit
Issue date: 10/08/1979
From: Newmark N
ILLINOIS, UNIV. OF, URBANA, IL
To:
References
Download: ML19210C163 (26)
Testimony of Ba Bolt Re Correlation Between Peak Acceleration & Magnitude & Intensity.Biography,Publication List & Supporting Documentation Encl
ML19210C160
Person / Time
Site: Skagit
Issue date: 10/08/1979
From: Bolt B
CALIFORNIA, UNIV. OF, BERKELEY, CA
To:
References
Download: ML19210C160 (39)
Forwards Prefiled Statements of Ba Bolt & Nm Newmark
ML19210C157
Person / Time
Site: Skagit
Issue date: 10/08/1979
From: Little D
PERKINS, COIE (FORMERLY PERKINS, COIE, STONE, OLSEN
To: DEALE V B, HOOPER F F, LINENBERGER G A
Atomic Safety and Licensing Board Panel
References
RTR-NUREG-CR-0098, RTR-NUREG-CR-98, TASK-02-04.F, TASK-2-4.F, TASK-RR
Download: ML19210C157 (2)